Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis

G Zhou, M Su, YL Yin, MH Li - Neurosurgical focus, 2017 - thejns.org
OBJECTIVE The objective of this study was to review the literature on the use of flow-
diverting devices (FDDs) to treat intracranial aneurysms (IAs) and to investigate the safety …

Braided stents and their impact in intracranial aneurysm treatment for distal locations: from flow diverters to low profile stents

C Iosif, A Biondi - Expert review of medical devices, 2019 - Taylor & Francis
Introduction: Intracranial aneurysms in distal locations are sometimes difficult to treat due to
their branching locations and the presence of blister-like or very wide-necked aneurysms …

Computational fluid dynamics analysis of flow reduction induced by flow-diverting stents in intracranial aneurysms: a patient-unspecific hemodynamics change …

R Ouared, I Larrabide, O Brina, P Bouillot… - Journal of …, 2016 - jnis.bmj.com
Background and purpose Flow-diverter stents (FDSs) have been used effectively to treat
large neck and complex saccular aneurysms on the anterior carotid circulation. Intra …

Introduction: history and development of flow diverter technology and evolution

AL Kühn, MJ Gounis, AS Puri - Neurosurgery, 2020 - journals.lww.com
The introduction of flow diverter technology to the field of neurointervention has
revolutionized the treatment of intracranial aneurysms. The therapy approach has shifted …

Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape

I Larrabide, ML Aguilar, HG Morales… - American Journal …, 2013 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Effects of blood flow modification by flow diverters are
observed to lead often to aneurysm thrombosis and reverse remodeling. For this process, to …

Pipeline embolization device in aneurysmal subarachnoid hemorrhage

JP Cruz, C O'Kelly, M Kelly, JH Wong… - American Journal …, 2013 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The PED is an FDS designed for the treatment of
intracranial aneurysms. Data regarding the use of this device in acute or subacute aSAH is …

An automatic CFD-based flow diverter optimization principle for patient-specific intracranial aneurysms

G Janiga, L Daróczy, P Berg, D Thévenin, M Skalej… - Journal of …, 2015 - Elsevier
The optimal treatment of intracranial aneurysms using flow diverting devices is a
fundamental issue for neuroradiologists as well as neurosurgeons. Due to highly irregular …

Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements

MR Levitt, PM McGah, A Aliseda… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Computational fluid dynamics modeling is useful in the
study of the hemodynamic environment of cerebral aneurysms, but patient-specific …

Assessment of the flow-diverter efficacy for intracranial aneurysm treatment considering pre-and post-interventional hemodynamics

J Stahl, LMM Marsh, M Thormann, A Ding… - Computers in Biology …, 2023 - Elsevier
Endovascular treatment of intracranial aneurysms with flow diverters (FD) has become one
of the most promising interventions. Due to its woven high-density structure they are …

Does the DSA reconstruction kernel affect hemodynamic predictions in intracranial aneurysms? An analysis of geometry and blood flow variations

P Berg, S Saalfeld, S Voß, T Redel, B Preim… - Journal of …, 2018 - jnis.bmj.com
Background Computational fluid dynamics (CFD) blood flow predictions in intracranial
aneurysms promise great potential to reveal patient-specific flow structures. Since the …