Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis

G Zhou, M Su, YL Yin, MH Li - Neurosurgical focus, 2017 - thejns.org
OBJECTIVE The objective of this study was to review the literature on the use of flow-
diverting devices (FDDs) to treat intracranial aneurysms (IAs) and to investigate the safety …

Efficacy and safety of the Woven EndoBridge (WEB) device for the treatment of intracranial aneurysms: a systematic review and meta-analysis

S Asnafi, A Rouchaud, L Pierot… - American Journal …, 2016 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Intrasaccular flow diverters are increasingly being used in
the treatment of wide-neck and bifurcation aneurysms. We performed a systematic review …

Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms: five-year results of the …

T Becske, W Brinjikji, MB Potts, DF Kallmes… - …, 2017 - journals.lww.com
BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the
Pipeline Embolization Device (PED) has been well demonstrated in prior studies …

Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies

DF Kallmes, W Brinjikji, S Cekirge, D Fiorella… - Journal of …, 2016 - thejns.org
OBJECTIVE The authors performed a pooled analysis of 3 studies—IntrePED (International
Retrospective Study of the Pipeline Embolization Device), PUFS (Pipeline for Uncoilable or …

Aneurysm study of pipeline in an observational registry (ASPIRe)

DF Kallmes, W Brinjikji, E Boccardi, E Ciceri… - Interventional …, 2016 - karger.com
Abstract Background and Objective: Few prospective studies exist evaluating the safety and
efficacy of the Pipeline Embolization Device (PED) in the treatment of intracranial …

Pipeline for uncoilable or failed aneurysms: 3-year follow-up results

T Becske, MB Potts, M Shapiro, DF Kallmes… - Journal of …, 2016 - thejns.org
OBJECTIVE The long-term effectiveness of endovascular treatment of large and giant wide-
neck aneurysms using traditional endovascular techniques has been disappointing, with …

Predictors of cerebral aneurysm persistence and occlusion after flow diversion: a single-institution series of 445 cases with angiographic follow-up

MT Bender, GP Colby, LM Lin, B Jiang… - Journal of …, 2018 - thejns.org
OBJECTIVE Flow diversion requires neointimal stent overgrowth to deliver aneurysm
occlusion. The existing literature on aneurysm occlusion is limited by heterogeneous follow …

Flow-diverter devices in the treatment of intracranial aneurysms: a meta-analysis and systematic review

X Lv, H Yang, P Liu, Y Li - The Neuroradiology Journal, 2016 - journals.sagepub.com
Objective The purpose of this report was to discuss the overall limitations, safety and efficacy
of flow-diverter stenting for intracranial aneurysms. Methods The authors performed a meta …

Flow diversion versus conventional treatment for carotid cavernous aneurysms

M Zanaty, N Chalouhi, RM Starke, G Barros, MP Saigh… - Stroke, 2014 - Am Heart Assoc
Background and Purpose—Several endovascular treatment options are available for
cavernous carotid aneurysms. We compared pipeline embolization device (PED) versus …

Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience

F Briganti, G Leone, L Ugga, M Marseglia… - Journal of …, 2017 - jnis.bmj.com
Background Experience with the endovascular treatment of cerebral aneurysms using the
p64 Flow Modulation Device is still limited. This study discusses the results and …