Semiautomated volumetric measurement on postcontrast MR imaging for analysis of recurrent and residual disease in glioblastoma multiforme
BACKGROUND AND PURPOSE: A limitation in postoperative monitoring of patients with
glioblastoma is the lack of objective measures to quantify residual and recurrent disease …
glioblastoma is the lack of objective measures to quantify residual and recurrent disease …
A novel, reproducible, and objective method for volumetric magnetic resonance imaging assessment of enhancing glioblastoma
Object Robust methodology that allows objective, automated, and observer-independent
measurements of brain tumor volume, especially after resection, is lacking. Thus …
measurements of brain tumor volume, especially after resection, is lacking. Thus …
Glioblastoma: does the pre-treatment geometry matter? A postcontrast T1 MRI-based study
Background The potential of a tumour's volumetric measures obtained from pretreatment
MRI sequences of glioblastoma (GBM) patients as predictors of clinical outcome has been …
MRI sequences of glioblastoma (GBM) patients as predictors of clinical outcome has been …
Measurement of tumor size in adult glioblastoma: classical cross-sectional criteria on 2D MRI or volumetric criteria on high resolution 3D MRI?
MY Wang, JL Cheng, YH Han, YL Li, JP Dai… - European journal of …, 2012 - Elsevier
OBJECTIVE: To investigate the added value of volume on post-contrast three dimensional
(3D) T1-weighted image (T1WI) over classical cross-sectional area on two dimensional (2D) …
(3D) T1-weighted image (T1WI) over classical cross-sectional area on two dimensional (2D) …
Volumetric quantification of glioblastoma: experiences with different measurement techniques and impact on survival
C Henker, T Kriesen, Ä Glass, B Schneider… - Journal of neuro …, 2017 - Springer
The potential impact of different radiological features of glioblastoma multiforme (GBM) on
overall survival (OS) like tumor volume, peritumoral edema (PTE), necrosis volume, necrosis …
overall survival (OS) like tumor volume, peritumoral edema (PTE), necrosis volume, necrosis …
Clinical target volume delineation in glioblastomas: pre-operative versus post-operative/pre-radiotherapy MRI
P Farace, MG Giri, G Meliado, D Amelio… - The British journal of …, 2011 - academic.oup.com
Objectives: Delineation of clinical target volume (CTV) is still controversial in glioblastomas.
In order to assess the differences in volume and shape of the radiotherapy target, the use of …
In order to assess the differences in volume and shape of the radiotherapy target, the use of …
Volumetric glioma quantification: comparison of manual and semi-automatic tumor segmentation for the quantification of tumor growth
A Odland, A Server, C Saxhaug, B Breivik… - Acta …, 2015 - journals.sagepub.com
Background Volumetric magnetic resonance imaging (MRI) is now widely available and
routinely used in the evaluation of high-grade gliomas (HGGs). Ideally, volumetric …
routinely used in the evaluation of high-grade gliomas (HGGs). Ideally, volumetric …
Progressive disease in glioblastoma: benefits and limitations of semi-automated volumetry
T Huber, G Alber, S Bette, J Kaesmacher… - PLoS …, 2017 - journals.plos.org
Purpose Unambiguous evaluation of glioblastoma (GB) progression is crucial, both for
clinical trials as well as day by day routine management of GB patients. 3D-volumetry in the …
clinical trials as well as day by day routine management of GB patients. 3D-volumetry in the …
Automatic estimation of extent of resection and residual tumor volume of patients with glioblastoma
OBJECTIVE In the treatment of glioblastoma, residual tumor burden is the only prognostic
factor that can be actively influenced by therapy. Therefore, an accurate, reproducible, and …
factor that can be actively influenced by therapy. Therefore, an accurate, reproducible, and …
Reliability of semi-automated segmentations in glioblastoma
T Huber, G Alber, S Bette, T Boeckh-Behrens… - Clinical …, 2017 - Springer
Purpose In glioblastoma, quantitative volumetric measurements of contrast-enhancing or
fluid-attenuated inversion recovery (FLAIR) hyperintense tumor compartments are needed …
fluid-attenuated inversion recovery (FLAIR) hyperintense tumor compartments are needed …