Characterization of intracranial mass lesions with in vivo proton MR spectroscopy.
PURPOSE To assess the use of in vivo proton MR spectroscopy for characterization of
intracranial mass lesions and to ascertain its reliability in grading of gliomas. METHODS …
intracranial mass lesions and to ascertain its reliability in grading of gliomas. METHODS …
[HTML][HTML] Proton MR spectroscopy of intracranial tumours: in vivo and in vitro studies
SS Gill, DGT Thomas… - Journal of …, 1990 - westminsterresearch.westminster.ac …
Proton magnetic resonance spectroscopy (1H MRS) was used to investigate intracranial
tumours in vitro and in vivo. Biopsy specimens were studied from 47 patients, 11 of whom …
tumours in vitro and in vivo. Biopsy specimens were studied from 47 patients, 11 of whom …
Clinical application of proton magnetic resonance spectroscopy in the diagnosis of intracranial mass lesions
W Möller-Hartmann, S Herminghaus, T Krings… - Neuroradiology, 2002 - Springer
Diagnosis of primary and secondary brain tumours and other focal intracranial mass lesions
based on imaging procedures alone is still a challenging problem. Proton magnetic …
based on imaging procedures alone is still a challenging problem. Proton magnetic …
Noninvasive evaluation of malignancy of brain tumors with proton MR spectroscopy.
H Shimizu, T Kumabe, T Tominaga… - American Journal …, 1996 - Am Soc Neuroradiology
PURPOSE To test clinical proton MR spectroscopy as a noninvasive method for predicting
tumor malignancy. METHODS Water-suppressed single-voxel point resolved spectroscopy …
tumor malignancy. METHODS Water-suppressed single-voxel point resolved spectroscopy …
Proton MR spectroscopy and preoperative diagnostic accuracy: an evaluation of intracranial mass lesions characterized by stereotactic biopsy findings
IM Burtscher, G Skagerberg, B Geijer… - American journal …, 2000 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: MR imaging has made it easier to distinguish among the
different types of intracranial mass lesions. Nevertheless, it is sometimes impossible to base …
different types of intracranial mass lesions. Nevertheless, it is sometimes impossible to base …
Proton magnetic resonance spectroscopy of pediatric brain tumors
LN Sutton, Z Wang, D Gusnard, B Lange… - …, 1992 - journals.lww.com
Abstract 1 H MAGNETIC RESONANCE spectroscopy allows the regional quantitation of a
number of metabolites from the brain in a noninvasive fashion. Spectra were obtained from 5 …
number of metabolites from the brain in a noninvasive fashion. Spectra were obtained from 5 …
Human brain tumors: spectral patterns detected with localized H-1 MR spectroscopy.
H Kugel, W Heindel, RI Ernestus, J Bunke, R Du Mesnil… - Radiology, 1992 - pubs.rsna.org
Image-guided localized proton magnetic resonance (MR) spectroscopy of intracranial
tumors was performed to correlate spectral patterns and histologic findings. Thirty-six …
tumors was performed to correlate spectral patterns and histologic findings. Thirty-six …
Proton MR spectroscopy of cerebral gliomas at 3 T: spatial heterogeneity, and tumour grade and extent
A Di Costanzo, T Scarabino, F Trojsi, T Popolizio… - European …, 2008 - Springer
This study aimed to evaluate the usefulness of proton MR spectroscopic imaging (1 H-MRSI)
at 3 T in differentiating high-from low-grade gliomas, and tumour from necrosis, oedema or …
at 3 T in differentiating high-from low-grade gliomas, and tumour from necrosis, oedema or …
Proton MR spectroscopy of common brain tumors.
M Castillo, L Kwock - Neuroimaging Clinics of North America, 1998 - europepmc.org
Proton MR spectroscopy allows differentiation of normal tissues from pathologic ones. There
is now evidence that this technique may be able to distinguish different histological grades …
is now evidence that this technique may be able to distinguish different histological grades …
Metabolic profiles of human brain tumors using quantitative in vivo 1H magnetic resonance spectroscopy
Proton spectroscopy can noninvasively provide useful information on brain tumor type and
grade. Short‐(30 ms) and long‐(136 ms) echo time (TE) 1H spectra were acquired from …
grade. Short‐(30 ms) and long‐(136 ms) echo time (TE) 1H spectra were acquired from …