Comparison of multiple sclerosis cortical lesion types detected by multicontrast 3T and 7T MRI

J Maranzano, M Dadar, DA Rudko… - American Journal …, 2019 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Our aims were the following: 1) to compare multicontrast
cortical lesion detection using 3T and 7T MR imaging, 2) to compare cortical lesion type …

Intracortical Lesions in Multiple Sclerosis: Improved Detection with 3D Double Inversion-Recovery MR Imaging1

JJG Geurts, PJW Pouwels, BMJ Uitdehaag, CH Polman… - Radiology, 2005 - pubs.rsna.org
PURPOSE: To prospectively compare the depiction of intracortical lesions by using multislab
three-dimensional (3D) double inversion-recovery (DIR), multislab 3D fluid-attenuated …

Cerebral cortical lesions in multiple sclerosis detected by MR imaging at 8 Tesla

A Kangarlu, EC Bourekas… - American Journal …, 2007 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Conventional imaging of ex-vivo brain at 1.5 T in multiple
sclerosis (MS) detects only a small fraction of the gray matter cerebral cortical lesions that …

3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions

EC Tallantyre, PS Morgan, JE Dixon… - Journal of Magnetic …, 2010 - Wiley Online Library
Cortical lesions are prevalent in multiple sclerosis but are poorly detected using MRI. The
double inversion recovery (DIR) sequence is increasingly used to explore the clinical …

Clinical application of multi-contrast 7-T MR imaging in multiple sclerosis: increased lesion detection compared to 3 T confined to grey matter

WL de Graaf, ID Kilsdonk, A Lopez-Soriano… - European …, 2013 - Springer
Abstract Objectives Seven-Tesla MRI demonstrated new pathological features of multiple
sclerosis (MS) using T2*-weighted sequences. However, a clinical MRI protocol at 7 T has …

Increased cortical grey matter lesion detection in multiple sclerosis with 7 T MRI: a post-mortem verification study

ID Kilsdonk, LE Jonkman, R Klaver, SJ van Veluw… - Brain, 2016 - academic.oup.com
The relevance of cortical grey matter pathology in multiple sclerosis has become
increasingly recognized over the past decade. Unfortunately, a large part of cortical lesions …

Improved detection of focal cortical lesions using 7 T magnetisation transfer imaging in patients with multiple sclerosis

R Abdel-Fahim, N Mistry, O Mougin… - Multiple sclerosis and …, 2014 - Elsevier
Background Cortical lesions account for a larger proportion of brain demyelination than
white matter (WM) lesions. They are often missed on conventional MRI. Recently studies …

Evolution of multiple sclerosis lesions on serial contrast-enhanced T1-weighted and magnetization-transfer MR images

A Rovira, J Alonso, G Cucurella… - American journal …, 1999 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Magnetization-transfer imaging is a technique that could
provide indirect evidence of the characteristics of multiple sclerosis (MS) lesions. The …

Multicontrast MR imaging at 7T in multiple sclerosis: highest lesion detection in cortical gray matter with 3D-FLAIR

ID Kilsdonk, WL de Graaf, AL Soriano… - American Journal …, 2013 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: 7T MR imaging has led to improved detection and
classification of cortical MS lesions, mainly based on T2*-weighted gradient-echo …

Improved visualization of cortical lesions in multiple sclerosis using 7T MP2RAGE

ES Beck, P Sati, V Sethi, T Kober… - American Journal …, 2018 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Cortical lesions are common and often extensive in
multiple sclerosis but are difficult to visualize by MRI, leaving important questions about their …