A flow-diverting stent is not a pressure-diverting stent

JJ Schneiders, E VanBavel… - American Journal …, 2013 - Am Soc Neuroradiology
The approach for treatment of large and fusiform intracranial aneurysms has evolved from
stent-assisted coiling to treatment with flow-diverting stents. The treatment results for these …

Aneurysm pressure measurement before and after placement of a Pipeline stent: feasibility study using a 0.014 inch pressure wire for coronary intervention

S Tateshima, JG Jones, FM Basto, F Vinuela… - Journal of …, 2016 - jnis.bmj.com
Flow-diverting stents have provided a new endovascular capacity to reconstruct an
intracranial aneurysm with its diseased parent artery. The results of first-generation flow …

Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment

JR Cebral, F Mut, M Raschi… - American journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow-diverting approaches to intracranial aneurysm
treatment had many promising early results, but recent apparently successful treatments …

Actual metal coverage at the neck is critical for flow-diverting stents in treating intracranial aneurysms

K Wang, S Yuan - American Journal of Neuroradiology, 2013 - Am Soc Neuroradiology
Stent.” The authors measured intra-aneurysmal pressure before, during, and after placement
of a flow-diverting (FD) stent and found that the pressure inside the aneurysm momentarily …

Small pipes: preliminary experience with 3-mm or smaller pipeline flow-diverting stents for aneurysm repair prior to regulatory approval

AR Martin, JP Cruz, C O'kelly, M Kelly… - American Journal …, 2015 - Am Soc Neuroradiology
Flow diversion has become an established treatment option for challenging intracranial
aneurysms. The use of small devices of≤ 3-mm diameter remains unapproved by major …

The use of flow-diverting stents in the treatment of giant cerebral aneurysms: preliminary results

L Cirillo, M Dall'Olio, C Princiotta… - The Neuroradiology …, 2010 - journals.sagepub.com
The treatment of giant cerebral aneurysms has always been a challenge for neurosurgeons
and neuroradiologists. Flow-diverting stents (Silk; Pipeline Embolization Device) are new …

Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements

MR Levitt, PM McGah, A Aliseda… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Computational fluid dynamics modeling is useful in the
study of the hemodynamic environment of cerebral aneurysms, but patient-specific …

Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms

B Lubicz, L Collignon, G Raphaeli, JP Pruvo… - Stroke, 2010 - Am Heart Assoc
Background and Purpose—The purpose of this study is to report our preliminary experience
with the flow-diverter Silk stent for the endovascular treatment of intracranial aneurysms …

Implantation of pipeline flow-diverting stents reduces aneurysm inflow without relevantly affecting static intra-aneurysmal pressure

HU Kerl, H Boll, T Fiebig, G Figueiredo, A Förster… - …, 2014 - journals.lww.com
BACKGROUND: Flow-diverting stent (FDS) implantation is an endovascular treatment
option for intracranial aneurysms. However, little is known about the hemodynamic effects …

Stents for intracranial wide-necked aneurysms: more than mechanical protection

I Wanke, M Forsting - Neuroradiology, 2008 - Springer
Abstract Treatment of wide-necked aneurysms by endovascular coil embolization usually
requires mechanical aids in order to protect the parent artery from occlusion due to …