Effects of increased image noise on image quality and quantitative interpretation in brain CT perfusion
BACKGROUND AND PURPOSE: There is a desire within many institutions to reduce the
radiation dose in CTP examinations. The purpose of this study was to simulate dose …
radiation dose in CTP examinations. The purpose of this study was to simulate dose …
Quantitative dose dependency analysis of whole-brain CT perfusion imaging
Purpose To quantitatively assess whether decreasing total radiation dose of the image
acquisition protocol has an effect on cerebral CT perfusion values in patients with acute …
acquisition protocol has an effect on cerebral CT perfusion values in patients with acute …
Patient dose in brain perfusion imaging using an 80-slice CT system
GAT Messaris, DN Georgakopoulos, P Zampakis… - Journal of …, 2019 - Elsevier
Background and purpose Brain CT Perfusion (CTP) is an X-ray imaging technique for the
assessment of brain tissue perfusion, which can be used in several different entities. The …
assessment of brain tissue perfusion, which can be used in several different entities. The …
Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)
Z Li, H Li, K Zhang, W Li, X Chen, B Wu, B Song - European radiology, 2014 - Springer
Objectives To investigate the feasibility of 70 kV cerebral CT perfusion by comparing image
quality and radiation exposure to 80 kV. Methods Thirty patients with suspected cerebral …
quality and radiation exposure to 80 kV. Methods Thirty patients with suspected cerebral …
Whole-brain adaptive 70-kVp perfusion imaging with variable and extended sampling improves quality and consistency while reducing dose
I Corcuera-Solano, AM McLellan… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Despite common use of CTP to assess cerebral
hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim …
hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim …
Radiation dose reduction in perfusion CT imaging of the brain using a 256-slice CT: 80 mAs versus 160 mAs
I Riederer, C Zimmer, D Pfeiffer, S Wunderlich… - Clinical Imaging, 2018 - Elsevier
Purpose To examine CTP of the brain in real patient data after reducing tube current down to
80 mAs to decrease radiation dose. Methods CTP was acquired in 60 suspected stroke …
80 mAs to decrease radiation dose. Methods CTP was acquired in 60 suspected stroke …
Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
Perfusion CT (PCT) of the brain is widely used in the settings of acute ischemic stroke and
vasospasm monitoring. The high radiation dose associated with PCT is a central topic and …
vasospasm monitoring. The high radiation dose associated with PCT is a central topic and …
Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol
JK Hoang, C Wang, DP Frush… - American journal of …, 2013 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to measure the organ doses and estimate the
effective dose for the standard brain perfusion CT protocol and erroneous protocols …
effective dose for the standard brain perfusion CT protocol and erroneous protocols …
Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging
Objectives To examine the impact of denoising on ultra-low-dose volume perfusion CT (ULD-
VPCT) imaging in acute stroke. Methods Simulated ULD-VPCT data sets at 20% dose rate …
VPCT) imaging in acute stroke. Methods Simulated ULD-VPCT data sets at 20% dose rate …
Low-dose volume-perfusion CT of the brain: effects of radiation dose reduction on performance of perfusion CT algorithms
Purpose We aimed to compare different computed tomography (CT) perfusion post-
processing algorithms regarding image quality of perfusion maps from low-dose volume …
processing algorithms regarding image quality of perfusion maps from low-dose volume …
Related searches
- image quality quantitative interpretation
- image quality radiation dose
- image quality perfusion of the brain
- radiation dose reduction volume perfusion
- dose reduction scan frequency
- dose reduction cerebral blood volume
- brain perfusion standard protocol
- brain perfusion radiation exposure
- dose reduction transit time
- quantitative parameters volume perfusion
- image denoising volume perfusion
- image denoising quantitative parameters
- image quality quantitative parameters
- image noise quantitative interpretation
- perfusion of the brain radiation dose
- dose reduction dynamic perfusion