Effects of increased image noise on image quality and quantitative interpretation in brain CT perfusion

K Juluru, JC Shih, A Raj… - American Journal …, 2013 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: There is a desire within many institutions to reduce the
radiation dose in CTP examinations. The purpose of this study was to simulate dose …

Quantitative dose dependency analysis of whole-brain CT perfusion imaging

R Manniesing, MTH Oei, B van Ginneken, M Prokop - Radiology, 2016 - pubs.rsna.org
Purpose To quantitatively assess whether decreasing total radiation dose of the image
acquisition protocol has an effect on cerebral CT perfusion values in patients with acute …

Patient dose in brain perfusion imaging using an 80-slice CT system

GAT Messaris, DN Georgakopoulos, P Zampakis… - Journal of …, 2019 - Elsevier
Background and purpose Brain CT Perfusion (CTP) is an X-ray imaging technique for the
assessment of brain tissue perfusion, which can be used in several different entities. The …

Improvement of image quality and radiation dose of CT perfusion of the brain by means of low-tube voltage (70 KV)

Z Li, H Li, K Zhang, W Li, X Chen, B Wu, B Song - European radiology, 2014 - Springer
Objectives To investigate the feasibility of 70 kV cerebral CT perfusion by comparing image
quality and radiation exposure to 80 kV. Methods Thirty patients with suspected cerebral …

Whole-brain adaptive 70-kVp perfusion imaging with variable and extended sampling improves quality and consistency while reducing dose

I Corcuera-Solano, AM McLellan… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Despite common use of CTP to assess cerebral
hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim …

Radiation dose reduction in perfusion CT imaging of the brain using a 256-slice CT: 80 mAs versus 160 mAs

I Riederer, C Zimmer, D Pfeiffer, S Wunderlich… - Clinical Imaging, 2018 - Elsevier
Purpose To examine CTP of the brain in real patient data after reducing tube current down to
80 mAs to decrease radiation dose. Methods CTP was acquired in 60 suspected stroke …

Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature

AE Othman, S Afat, MA Brockmann… - Journal of …, 2016 - Elsevier
Perfusion CT (PCT) of the brain is widely used in the settings of acute ischemic stroke and
vasospasm monitoring. The high radiation dose associated with PCT is a central topic and …

Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol

JK Hoang, C Wang, DP Frush… - American journal of …, 2013 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to measure the organ doses and estimate the
effective dose for the standard brain perfusion CT protocol and erroneous protocols …

Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging

AE Othman, C Brockmann, Z Yang, C Kim, S Afat… - European …, 2016 - Springer
Objectives To examine the impact of denoising on ultra-low-dose volume perfusion CT (ULD-
VPCT) imaging in acute stroke. Methods Simulated ULD-VPCT data sets at 20% dose rate …

Low-dose volume-perfusion CT of the brain: effects of radiation dose reduction on performance of perfusion CT algorithms

AE Othman, S Afat, C Brockmann… - Clinical …, 2017 - Springer
Purpose We aimed to compare different computed tomography (CT) perfusion post-
processing algorithms regarding image quality of perfusion maps from low-dose volume …