Measurement of cerebral hemodynamics with perfusion-weighted MR imaging: comparison with pre-and post-acetazolamide 133Xe-SPECT in occlusive carotid …
K Kikuchi, K Murase, H Miki, T Kikuchi… - American Journal …, 2001 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: We generated regional cerebral blood volume (rCBV) and
regional cerebral blood flow (rCBF) studies from dynamic susceptibility contrast-enhanced …
regional cerebral blood flow (rCBF) studies from dynamic susceptibility contrast-enhanced …
Measurement of cerebral blood flow in chronic carotid occlusive disease: comparison of dynamic susceptibility contrast perfusion MR imaging with positron emission …
P Mukherjee, HC Kang, TO Videen… - American Journal …, 2003 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Our purpose was to evaluate the accuracy of cerebral
blood flow (CBF) measurements obtained by using dynamic susceptibility contrast …
blood flow (CBF) measurements obtained by using dynamic susceptibility contrast …
Correlative assessment of hemodynamic parameters obtained with T2*-weighted perfusion MR imaging and SPECT in symptomatic carotid artery occlusion
JH Kim, SJ Lee, T Shin, KH Kang… - American journal …, 2000 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Perfusion MR imaging and single-photon emission CT
(SPECT) are commonly used to evaluate hemodynamic status in patients with symptomatic …
(SPECT) are commonly used to evaluate hemodynamic status in patients with symptomatic …
Severe occlusive carotid artery disease: hemodynamic assessment by MR perfusion imaging in symptomatic patients
M Maeda, WTC Yuh, T Ueda… - American journal …, 1999 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Cerebral hemodynamic status has been reported to
influence the occurrence and outcome of acute stroke. The purpose of this study was to …
influence the occurrence and outcome of acute stroke. The purpose of this study was to …
Quantitative Evaluation of Mean Transit Times Obtained with Dynamic Susceptibility Contrast-Enhanced MR Imaging and with 133Xe SPECT in Occlusive …
K Kikuchi, K Murase, H Miki… - American journal of …, 2002 - Am Roentgen Ray Soc
OBJECTIVE. We report on quantitative mean transit time images obtained using dynamic
susceptibility contrast-enhanced MR imaging after an IV bolus injection of a contrast agent …
susceptibility contrast-enhanced MR imaging after an IV bolus injection of a contrast agent …
Cerebral hemodynamic evaluation using perfusion-weighted magnetic resonance imaging: comparison with positron emission tomography values in chronic …
K Kajimoto, H Moriwaki, N Yamada, K Hayashida… - Stroke, 2003 - Am Heart Assoc
Background and Purpose—Perfusion-weighted magnetic resonance imaging (PWI) is a
reliable and semiquantitative method for estimating cerebral hemodynamics. We sought to …
reliable and semiquantitative method for estimating cerebral hemodynamics. We sought to …
Reliability of perfusion MR imaging in symptomatic carotid occlusive disease: Cerebral blood volume, mean transit time and time-to-peak
JH K011011011011011011im… - Acta …, 2002 - Taylor & Francis
Purpose: Perfusion MR imaging offers an easy quantitative evaluation of relative regional
cerebral blood volume (rrCBV), relative mean transit time (rMTT) and time-to-peak (TTP) …
cerebral blood volume (rrCBV), relative mean transit time (rMTT) and time-to-peak (TTP) …
Cerebrovascular Occlusive Disease: Quantitative Cerebral Blood Flow Using Dynamic Susceptibility Contrast MR Imaging Correlates with Quantitative H2[15O] PET
Purpose To compare quantitative values of cerebral blood flow (CBF) derived from dynamic
susceptibility contrast (DSC) magnetic resonance (MR) imaging with reference standard …
susceptibility contrast (DSC) magnetic resonance (MR) imaging with reference standard …
Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging
Quantitative, multislice dynamic susceptibility contrast-enhanced MRI perfusion
measurements were used to determine the patterns of cerebral blood flow (CBF), cerebral …
measurements were used to determine the patterns of cerebral blood flow (CBF), cerebral …
Correlative assessment of cerebral blood flow obtained with perfusion CT and positron emission tomography in symptomatic stenotic carotid disease
S Bisdas, O Nemitz, G Berding, K Weissenborn… - European …, 2006 - Springer
Twelve patients with ICA stenosis underwent dynamic perfusion computed tomography (CT)
and positron emission tomography (PET) studies at rest and after acetazolamide challenge …
and positron emission tomography (PET) studies at rest and after acetazolamide challenge …
Related searches
- 133xe spect cerebral hemodynamics
- blood volume perfusion mr imaging
- blood flow susceptibility contrast
- cerebral blood volume transit time
- hemodynamic parameters artery occlusion
- correlative assessment artery occlusion
- blood flow correlative assessment
- perfusion imaging hemodynamic assessment
- perfusion imaging artery disease
- perfusion imaging symptomatic patients
- artery disease hemodynamic assessment
- perfusion imaging artery stenosis