Angiographic and histologic comparison of experimental aneurysms embolized with hydrogel filaments
M Killer, DF Kallmes, MR McCoy… - American journal …, 2009 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The embolization of aneurysms with hydrogel filaments
allow postprocedural CT and MR imaging studies without artifacts. We compared the …
allow postprocedural CT and MR imaging studies without artifacts. We compared the …
Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil
YH Ding, D Dai, DA Lewis, HJ Cloft… - American Journal of …, 2005 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: A report directly comparing platinum coils, Matrix coils,
and Hydro Coil s in a single animal model does not currently exist. We evaluated and …
and Hydro Coil s in a single animal model does not currently exist. We evaluated and …
New expandable hydrogel-platinum coil hybrid device for aneurysm embolization
DF Kallmes, NH Fujiwara - American Journal of …, 2002 - Am Soc Neuroradiology
This study introduces a new, hybrid embolic device that in addition to offering all the
important attributes of existing detachable platinum coils also shows an enhanced ability to …
important attributes of existing detachable platinum coils also shows an enhanced ability to …
Comparison of experimental aneurysms embolized with second-generation embolic devices and platinum coils
M Killer, T Hauser, A Wenger, B Richling… - Acta neurochirurgica, 2009 - Springer
Purpose The purpose of the study was to compare the performance of second-generation
embolic devices with that of platinum coils in experimental aneurysms. Methods …
embolic devices with that of platinum coils in experimental aneurysms. Methods …
A collagen-based coil for embolization of saccular aneurysms in a New Zealand White rabbit model
DF Kallmes, NH Fujiwara, D Yuen… - American Journal of …, 2003 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: In the treatment of cerebral aneurysms, platinum coils
often fail to elicit a fibrotic response. We tested the hypothesis that a new, collagen-based …
often fail to elicit a fibrotic response. We tested the hypothesis that a new, collagen-based …
Use of CT angiography in comparison with other imaging techniques for the determination of embolus and remnant size in experimental aneurysms embolized with …
M Killer, MR McCoy, MC Vestal… - American journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Beam-hardening artifacts in CTA can be greatly reduced
by using metal-free coils for aneurysm embolization. We compared the embolic masses and …
by using metal-free coils for aneurysm embolization. We compared the embolic masses and …
Hydrogel-coated and platinum coils for intracranial aneurysm embolization compared in three experimental models using computerized angiographic and histologic …
GM Cruise, JC Shum, H Plenk - Journal of Materials Chemistry, 2007 - pubs.rsc.org
Angiographic and histologic results of hydrogel-coated (HydroCoil®) and platinum coil-
treated canine sidewall, canine bifurcation, and rabbit elastase aneurysms (2–52 weeks …
treated canine sidewall, canine bifurcation, and rabbit elastase aneurysms (2–52 weeks …
Bioabsorbable polymeric material coils for embolization of intracranial aneurysms: a preliminary experimental study
Y Murayama, F Viñuela, S Tateshima, JK Song… - Journal of …, 2001 - thejns.org
Object. A new embolic agent, bioabsorbable polymeric material (BPM), was incorporated
into Guglielmi detachable coils (GDCs) to improve long-term anatomical results in the …
into Guglielmi detachable coils (GDCs) to improve long-term anatomical results in the …
Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure …
Background and Purpose—The durability of aneurysm coil embolization is thought to
depend on packing density. The expansile property of hydrogel coating on coils increases …
depend on packing density. The expansile property of hydrogel coating on coils increases …
Embolization of intracranial aneurysms with hydrogel-coated coils: result of a Korean multicenter trial
HS Kang, MH Han, TH Lee, YS Shin, HG Roh… - …, 2007 - journals.lww.com
OBJECTIVE: HydroCoil (MicroVention, Aliso Viejo, CA), a hydrogel-platinum coil hybrid
device, is one of various efforts to overcome delayed recanalization of coiled intracranial …
device, is one of various efforts to overcome delayed recanalization of coiled intracranial …
Related searches
- hydrogel filaments experimental aneurysms
- angiography in comparison experimental aneurysms
- embolic devices experimental aneurysms
- platinum coils experimental aneurysms
- hydrogel filaments angiography in comparison
- hydrogel filaments remnant size
- remnant size experimental aneurysms
- embolic devices platinum coils
- platinum coils histologic morphometry
- hydrogel platinum aneurysm embolization
- histologic morphometry aneurysm embolization
- platinum coils aneurysm embolization