Measuring 3D Cochlear Duct Length on MRI: Is It Accurate and Reliable?

MB Eser, B Atalay, MB Dogan… - American Journal …, 2021 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Prior studies have evaluated cochlear length using CT to
select the most suitable cochlear implants and obtain patient-specific anatomy. This study …

Comparing cochlear duct lengths between CT and MR images using an otological surgical planning software

NA George-Jones, AM Tolisano, JW Kutz Jr… - Otology & …, 2020 - journals.lww.com
Objective: We sought to examine the intra-and interobserver variability in measuring the
cochlear duct length (CDL) from magnetic resonance imaging (MRI) images versus …

Cochlear duct length measurements in computed tomography and magnetic resonance imaging using newly developed techniques

J Taeger, FT Müller-Graff, L Ilgen… - OTO …, 2021 - journals.sagepub.com
Objective Growing interest in measuring the cochlear duct length (CDL) has emerged, since
it can influence the selection of cochlear implant electrodes. Currently the measurements …

Determination of cochlear duct length with 3D versus two-dimensional methods: A retrospective clinical study of imaging by computed tomography and cone beam …

S Waldeck, C VON FALCK, R Chapot, M Brockmann… - in vivo, 2021 - iv.iiarjournals.org
Background: The aim of this study was to compare three different methods for measurement
of cochlear duct length (CDL) in the clinical setting for two different imaging modalities …

Use of MRI to determine cochlear duct length in patients undergoing cochlear implantation

R Nash, S Otero, J Lavy - Cochlear Implants International, 2019 - Taylor & Francis
Objectives: It is recognised that CT can be used to determine the cochlear duct length (CDL)
when selecting an electrode for cochlear implantation. It is the practice of our institution to …

[HTML][HTML] CT imaging-based approaches to cochlear duct length estimation—A human temporal bone study

T Breitsprecher, A Dhanasingh, M Schulze, M Kipp… - European …, 2022 - Springer
Objectives Knowledge about cochlear duct length (CDL) may assist electrode choice in
cochlear implantation (CI). However, no gold standard for clinical applicable estimation of …

Dependence of Cochlear Duct Length Measurement on the Resolution of the Imaging Dataset

B Spahn, L Ilgen, T Neun, FT Müller-Graff… - Otology & …, 2023 - journals.lww.com
Background Previous research has shown highly precise cochlear measurements using 3D-
curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography …

Fully automated measurement of cochlear duct length from clinical temporal bone computed tomography

CA Neves, ED Tran, SP Cooperman… - The …, 2022 - Wiley Online Library
Objectives/Hypothesis To present and validate a novel fully automated method to measure
cochlear dimensions, including cochlear duct length (CDL). Study Design Cross‐sectional …

Precise evaluation of the cochlear duct length by flat-panel volume computed tomography (fpVCT)—implication of secondary reconstructions

P Schendzielorz, L Ilgen, T Mueller-Graff… - Otology & …, 2021 - journals.lww.com
Background: Cochlear geometry is a controversially debated topic. In the meantime, there
are many different studies partly reporting highly divergent values. Our aim is to discuss the …

Curvilinear multiplanar reconstruction to predict useful length and diameter of cochlear lumen for cochlear implantation

C Guigou, A Schein, P Trouilloud, A Lalande… - Otology & …, 2020 - journals.lww.com
Objective: Evaluate the useful length and the diameter of the cochlear lumen (CL) using
routine imaging before cochlear implantation to study inter-individual variability and its …