Balloon-guide catheters are needed for effective flow reversal during mechanical thrombectomy

O Nikoubashman, D Wischer… - American Journal …, 2018 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Blood flow management in the carotid artery during
mechanical thrombectomy is crucial for safety and effectiveness. There is an ongoing …

Maximizing the catheter-to-vessel size optimizes distal flow control resulting in improved revascularization in vitro for aspiration thrombectomy

RG Nogueira, D Ryan, L Mullins, J Thornton… - Journal of …, 2022 - jnis.bmj.com
Background Balloon guide catheters (BGCs) achieve proximal flow control during
thrombectomy but antegrade intracranial flow often persists via the Circle of Willis. Closely …

In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion

P Mordasini, N Frabetti, J Gralla… - American Journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The use of self-expanding retrievable stents is an
emerging and promising treatment strategy for acute stroke treatment. The concept …

Interaction between the stent strut and thrombus characterized by contrast-enhanced high-resolution cone beam CT during deployment of the Solitaire stent retriever

T Tsumoto, Y Tsurusaki, S Tokunaga - Journal of NeuroInterventional …, 2017 - jnis.bmj.com
Background The mechanism by which a stent retriever removes intraluminal thrombus from
an occluded vessel in humans has not previously been studied. This study performed …

Can a stent retriever damage the JET 7 reperfusion catheter?

JP Ti, L Yeo, G Anil - American Journal of Neuroradiology, 2020 - Am Soc Neuroradiology
We encountered 2 separate instances of damage to JET 7 reperfusion catheters when they
were used in conjunction with a stent retriever during mechanical thrombectomy. On both …

A stent-retrieving into an aspiration catheter with proximal balloon (ASAP) technique: a technique of mechanical thrombectomy

S Goto, T Ohshima, K Ishikawa, T Yamamoto… - World neurosurgery, 2018 - Elsevier
Objective The best technique for the first attempt at mechanical thrombectomy for acute
ischemic stroke is a still matter of debate. In this study, we evaluate the efficacy of a stent …

Stent-thrombus interaction and the influence of aspiration on mechanical thrombectomy: evaluation of different stent retrievers in a circulation model

J Madjidyar, J Hermes, S Freitag-Wolf, O Jansen - Neuroradiology, 2015 - Springer
Introduction Different devices and techniques are available for endovascular treatment of
ischemic stroke. In this in vitro study, we examined the stent-thrombus interaction and the …

Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison

M Mokin, CN Ionita, SVS Nagesh, S Rudin… - Journal of …, 2015 - jnis.bmj.com
Background Artificial stroke models can be used for testing various thrombectomy devices.
Objective To determine the value of combined stentriever–aspiration thrombectomy …

The effect of distal aspiration catheter position on collateral flow in mechanical thrombectomy – an in vitro study

W Jakobek, G Gravino, S Nayak… - Interventional …, 2023 - journals.sagepub.com
Introduction Endovascular mechanical thrombectomy for ischaemic stroke is one of the most
effective treatments. Despite the devices and techniques that have been developed, thrombi …

Influence of thrombus composition on thrombectomy: ADAPT vs. balloon guide catheter and stent retriever in a flow model

J Madjidyar, LP Vidal, N Larsen… - RöFo-Fortschritte auf …, 2020 - thieme-connect.com
Purpose A first-pass, direct aspiration technique and stent retrieval with a balloon guide
catheter represent advanced thrombectomy techniques that are increasingly being used in …