Experimental flat-panel high-spatial-resolution volume CT of the temporal bone

R Gupta, SH Bartling, SK Basu… - American journal …, 2004 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: A CT scanner employing a digital flat-panel detector is
capable of very high spatial resolution as compared with a multi-section CT (MSCT) …

Temporal bone imaging: comparison of flat panel volume CT and multisection CT

O Majdani, K Thews, S Bartling… - American journal …, 2009 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: A recent development in radiology is the use of flat panel
detectors in CT to obtain higher-resolution images. This technique is known as flat panel …

Flat-panel CT versus 128-slice CT in temporal bone imaging: assessment of image quality and radiation dose

L Piergallini, E Scola, B Tuscano, R Brambilla… - European Journal of …, 2018 - Elsevier
Objective We compared the image quality and radiation dose of flat-panel CT (FPCT) and
multi-slice CT (MSCT) performed respectively with an angiographic unit and a 128-slice CT …

Cone-beam volumetric tomography for applications in the temporal bone

RT Penninger, TS Tavassolie, JP Carey - Otology & Neurotology, 2011 - journals.lww.com
Background: Imaging of SCD has traditionally used MSCT, but the ability to resolve thin
bone next to low-radiodensity brain and inner ear fluids at the interface of the superior canal …

Temporal bone CT: improved image quality and potential for decreased radiation dose using an ultra-high-resolution scan mode with an iterative reconstruction …

S Leng, FE Diehn, JI Lane, KK Koeller… - American Journal …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Radiation dose in temporal bone CT imaging can be high
due to the requirement of high spatial resolution. In this study, we assessed whether CT …

Delineation of temporal bone anatomy: feasibility of low-dose 64-row CT in regard to image quality

J Lutz, V Jäger, MJ Hempel, S Srivastav, M Reiser… - European …, 2007 - Springer
The aim of our present study was to evaluate the visualization of anatomical landmarks of
the temporal bone using a low-dose 64-slice computed tomography (CT) technique. A total …

Ultrahigh-resolution CT scan of the temporal bone

K Yamashita, A Hiwatashi, O Togao, K Kikuchi… - European Archives of …, 2018 - Springer
Abstract Objective Ultrahigh-resolution CT (U-HRCT) provides better spatial resolution than
conventional multi-detector row CT (ConvCT) and could be expected to identify …

CT of the normal temporal bone: Comparison of multi–and single–detector row CT

L Jäger, H Bonell, M Liebl, S Srivastav, V Arbusow… - Radiology, 2005 - pubs.rsna.org
PURPOSE: To evaluate multi–and single–detector row computed tomographic (CT)
depiction of anatomic landmarks of temporal bone. MATERIALS AND METHODS …

A new frontier in temporal bone imaging: photon-counting detector CT demonstrates superior visualization of critical anatomic structures at reduced radiation dose

JC Benson, K Rajendran, JI Lane… - American Journal …, 2022 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Photon-counting detector CT is a new technology with a
limiting spatial resolution of≤ 150 μm. In vivo comparisons between photon-counting …

Comparison of a photon-counting-detector CT with an energy-integrating-detector CT for temporal bone imaging: a cadaveric study

W Zhou, JI Lane, ML Carlson… - American Journal …, 2018 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Evaluating abnormalities of the temporal bone requires
high-spatial-resolution CT imaging. Our aim was to assess the performance of photon …