Comparison of Enhancement of the Vestibular Perilymph between Variable and Constant Flip Angle–Delayed 3D-FLAIR Sequences in Menière Disease

S Nahmani, A Vaussy, C Hautefort… - American Journal …, 2020 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Endolymphatic hydrops in patients with Menière disease
relies on delayed postcontrast 3D-FLAIR sequences. The purpose of this study was to …

Optimized 3D-FLAIR sequences to shorten the delay between intravenous administration of gadolinium and MRI acquisition in patients with Menière's disease

J Barlet, A Vaussy, Y Ejzenberg, M Toupet… - European …, 2022 - Springer
Objectives The aim of this study was to shorten the 4-h delay between the intravenous
administration of gadolinium and MRI acquisition for hydrops evaluation using an optimized …

Intratympanic contrast in the evaluation of Menière disease: understanding the limits

J Bykowski, JP Harris, M Miller, J Du… - American Journal of …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Studies describing endolymphatic hydrops in Menière
disease after off-label intratympanic gadolinium-based contrast have been limited by long …

Detection and grading of endolymphatic hydrops in Menière disease using MR imaging

K Baráth, B Schuknecht, AM Naldi… - American Journal …, 2014 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Endolymphatic hydrops has been recognized as the
underlying pathophysiology of Menière disease. We used 3T MR imaging to detect and …

3D-real IR MRI of Meniere's disease with partial endolymphatic hydrops

S Shi, F Zhou, W Wang - American Journal of Otolaryngology, 2019 - Elsevier
Objectives A three-dimensional inversion-recovery sequence with real reconstruction (3D-
real IR) sequence 4 h after intravenous gadolinium injection (IV) has been used to visualize …

[HTML][HTML] The value of four stage vestibular hydrops grading and asymmetric perilymphatic enhancement in the diagnosis of Menière's disease on MRI

A Bernaerts, R Vanspauwen, C Blaivie, J van Dinther… - Neuroradiology, 2019 - Springer
Purpose There is still a clinical-radiologic discrepancy in patients with Menière's disease
(MD). Therefore, the purpose of this study was to investigate the reliability of current MRI …

MR imaging in Menière disease: is the contact between the vestibular endolymphatic space and the oval window a reliable biomarker?

G Conte, L Caschera, S Calloni… - American Journal …, 2018 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: No reliable MR imaging marker for the diagnosis of
Menière disease has been reported. Our aim was to investigate whether the obliteration of …

Endolymphatic hydrops evaluation on MRI: practical considerations

RM Loureiro, DV Sumi, HLVC Tames… - American Journal of …, 2020 - Elsevier
Four-hour delayed three-dimensional fluid-attenuated inversion recovery (3D-FLAIR)
sequence after intravenous gadolinium-based contrast agent administration is an optimal …

Value of endolymphatic hydrops and perilymph signal intensity in suspected Ménière disease

JM Van Steekelenburg… - American Journal …, 2020 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Ménière disease is characterized by endolymphatic
hydrops, whereas perilymphatic enhancement on MR imaging has been suggested to be of …

[HTML][HTML] Vestibular endolymphatic hydrops visualized by magnetic resonance imaging and its correlation with vestibular functional test in patients with unilateral …

Y Liu, F Zhang, B He, J He, Q Zhang, J Yang… - Frontiers in …, 2021 - frontiersin.org
Background: Currently, 3 Tesla-MRI following intratympanic gadolinium injection has made
it possible to assess the existence and the severity of hydrops in each compartment of the …