Extra-aneurysmal flow modification following pipeline embolization device implantation: focus on regional branches, perforators, and the parent vessel

G Gascou, K Lobotesis, H Brunel… - American Journal …, 2015 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow-diverter technology has proved to be a safe and
effective treatment for intracranial aneurysm based on the concept of flow diversion allowing …

Collar sign in incompletely occluded aneurysms after Pipeline embolization: evaluation with angiography and optical coherence tomography

CJ Griessenauer, R Gupta, S Shi… - American Journal …, 2017 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device has
emerged as an attractive treatment for cerebral aneurysms. Processes involved in aneurysm …

Clinical and angiographic outcomes in patients with intracranial aneurysms treated with the pipeline embolization device: intra-procedural technical difficulties, major …

JE Delgado Almandoz, Y Kayan, A Tenreiro… - Neuroradiology, 2017 - Springer
Purpose Flow diversion constitutes a pivotal advancement in endovascular intracranial
aneurysm treatment, but requires development of a new skill set. The aim of this study is to …

Flow diverter therapy with the pipeline embolization device is associated with an elevated rate of delayed fluid-attenuated inversion recovery lesions

MG Safain, M Roguski, RS Heller, AM Malek - Stroke, 2016 - Am Heart Assoc
Background and Purpose—Flow diversion using the Pipeline Embolization Device is
reported as a safe treatment of aneurysms. Complete aneurysm occlusion, however, occurs …

The Pipeline embolization device for treatment of intracranial aneurysms

JL Eller, TM Dumont, GC Sorkin, M Mokin… - Expert review of …, 2014 - Taylor & Francis
Flow diversion is a new endovascular technique developed for treatment of intracranial
aneurysms. It is based on stent-induced modification of blood flow within and around an …

Acute branch occlusion after Pipeline embolization of intracranial aneurysms

RR Lall, E Crobeddu, G Lanzino, HJ Cloft… - Journal of Clinical …, 2014 - Elsevier
Flow-diverters are used in the treatment of large and complex intracranial aneurysms. One
major concern with this concept is the potential for compromise of side branches and …

Flow diversion versus traditional aneurysm embolization strategies: analysis of fluoroscopy and procedure times

N Chalouhi, JF McMahon, LA Moukarzel… - Journal of …, 2014 - jnis.bmj.com
Background and objective Flow diverters are increasingly used for treatment of complex
intracranial aneurysms. The purpose of this study was to compare the pipeline embolization …

Relationship between haemodynamic changes and outcomes of intracranial aneurysms after implantation of the pipeline embolisation device: a single centre study

J Chen, Y Zhang, Z Tian, W Li… - Interventional …, 2019 - journals.sagepub.com
Background Intracranial aneurysms are increasingly being treated by the placement of flow
diverters; however, the factors affecting the outcome of aneurysms treated using flow …

The pipeline embolization device for the intracranial treatment of aneurysms trial

PK Nelson, P Lylyk, I Szikora… - American Journal …, 2011 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Endoluminal reconstruction with flow diverting devices
represents a novel constructive technique for the treatment of cerebral aneurysms. We …

Small pipes: preliminary experience with 3-mm or smaller pipeline flow-diverting stents for aneurysm repair prior to regulatory approval

AR Martin, JP Cruz, C O'kelly, M Kelly… - American Journal …, 2015 - Am Soc Neuroradiology
Flow diversion has become an established treatment option for challenging intracranial
aneurysms. The use of small devices of≤ 3-mm diameter remains unapproved by major …