[HTML][HTML] Pipeline Sizing Based on Computer Simulation
T Becske - AJNR: American Journal of Neuroradiology, 2019 - ncbi.nlm.nih.gov
Flow-diversion treatment of cerebral aneurysms with the Pipe-line Embolization Device
(Covidien, Irvine, California) has been around for nearly 13 years, yet we are still struggling …
(Covidien, Irvine, California) has been around for nearly 13 years, yet we are still struggling …
On flow diversion: the changing landscape of intracerebral aneurysm management
AA Dmytriw, K Phan, JM Moore… - American Journal …, 2019 - Am Soc Neuroradiology
Uptake of flow-diverting technology is rapidly outpacing the availability of clinical evidence.
Most current usage is off-label, and the endovascular community is nearer the beginning …
Most current usage is off-label, and the endovascular community is nearer the beginning …
Unsuccessful Flow-diverter Treatment: a Patient-specific Computational Flow Dynamics Study on Failed Aneurysms
Introduction: Flow diverting stents shifted the paradigm in endovascular management of
intracranial aneurysms, with aneurysm obliteration rate of over 80% by 6 months. However …
intracranial aneurysms, with aneurysm obliteration rate of over 80% by 6 months. However …
P-002 The financial impact of flow diverters on the endovascular treatment of cerebral aneurysms
A Rai, B Cline, A Tarabishy, J Patterson… - Journal of …, 2014 - jnis.bmj.com
Introduction If flow-diverters are to become the preferred mode of treating aneurysms then
other than their efficacy, an analysis of their financial impact against coiling is warranted …
other than their efficacy, an analysis of their financial impact against coiling is warranted …
Pipeline embolization device diameter is an important factor determining the efficacy of flow diversion treatment of small intracranial saccular aneurysms
MJ Kole, TR Miller, G Cannarsa, A Wessell… - Journal of …, 2019 - jnis.bmj.com
Objective Flow diversion using the Pipeline embolization device (PED) has become a widely
used treatment method for intracranial aneurysms. However, a subset of aneurysms will fail …
used treatment method for intracranial aneurysms. However, a subset of aneurysms will fail …
E-024 One-decade outcomes of flow-diversion for intracranial aneurysms with the pipeline embolization device
Introduction/Purpose Flow-diverter devices have revolutionized the treatment of intracranial
aneurysms since their approval in 2011 and have continued to evolve. The devices have …
aneurysms since their approval in 2011 and have continued to evolve. The devices have …
Predictors of incomplete aneurysm occlusion after treatment with the Pipeline Embolization Device: PREMIER trial 1 year analysis
RA Hanel, A Monteiro, PK Nelson, DK Lopes… - Journal of …, 2022 - jnis.bmj.com
Background Flow diverters have revolutionized the treatment of intracranial aneurysms.
Nevertheless, some aneurysms fail to occlude with flow diversion. The Prospective Study on …
Nevertheless, some aneurysms fail to occlude with flow diversion. The Prospective Study on …
Defining the optimal target for endovascular flow diversion using intracranial aneurysm and parent vessel morphometry
D Ding - Acta neurochirurgica, 2014 - Springer
Dear Editor, I have read with interest a recently published article in Acta Neurochirurgica by
Tykocki and Kostkiewicz titled “Aneurysms of the anterior and posterior cerebral circulation …
Tykocki and Kostkiewicz titled “Aneurysms of the anterior and posterior cerebral circulation …
Pipeline embolization device with or without adjunctive coil embolization: analysis of complications from the IntrePED registry
MS Park, C Kilburg, P Taussky… - American Journal …, 2016 - Am Soc Neuroradiology
Flow diversion to treat cerebral aneurysms has revolutionized neurointerventional surgery.
Because the addition of coils potentially increases the time and complexity of endovascular …
Because the addition of coils potentially increases the time and complexity of endovascular …
Comparison of pipeline embolization device sizing based on conventional 2D measurements and virtual simulation using the Sim&Size software: an agreement study
JM Ospel, G Gascou, V Costalat… - American Journal …, 2019 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: The Sim&Size software simulates case-specific
intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in …
intraluminal Pipeline Embolization Device behavior, wall apposition, and device length in …
Related searches
- computer simulation pipeline sizing
- flow diversion procedure times
- flow diversion aneurysm management
- flow diversion analysis of fluoroscopy
- flow diversion changing landscape
- cerebral aneurysms endovascular treatment
- cerebral aneurysms financial impact
- flow diversion intracranial aneurysms
- cerebral aneurysms flow diverters