Results of 101 aneurysms treated with polyglycolic/polylactic acid microfilament nexus coils compared with historical controls treated with standard coils

WJ Van Rooij, AN De Gast… - American journal of …, 2008 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Polyglycolic/polylactic acid (PGLA) addition to bare
platinum coils is intended to reduce the reopening rate of coiled intracranial aneurysms …

Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer–coated coils compared to historical controls treated with bare platinum …

HS Kang, MH Han, BJ Kwon… - American Journal …, 2005 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Aneurysm recanalization is an innate problem in
endovascular treatment of aneurysms with coils. A coated coil system, covered with a …

Guglielmi detachable coils versus matrix coils: a comparison of the immediate posttreatment results of the embolization of 364 cerebral aneurysms in 307 patients: a …

V Katsaridis, C Papagiannaki… - American journal of …, 2006 - Am Soc Neuroradiology
BACKGROUND: Matrix coils are based on Gugliemi detachable coils (GDC) but are covered
with polyglycolic/polylactic acid. We present our experience regarding the immediate …

Intracranial aneurysm coiling with PGLA-coated coils versus bare platinum coils: long-term anatomic follow-up

M Piotin, S Pistocchi, B Bartolini, R Blanc - Neuroradiology, 2012 - Springer
Introduction The purpose of this study is to compare the long-term (≥ 12 months)
angiographic follow-up of aneurysms treated with polymer polyglycolic-lactic acid (PGLA) …

Polyglycolide/polylactide-coated platinum coils for patients with ruptured and unruptured cerebral aneurysms: a single-center experience

I Linfante, NM Akkawi, A Perlow, V Andreone… - Stroke, 2005 - Am Heart Assoc
Background and Purpose—Recanalization of cerebral aneurysm is a limitation of bare
platinum coils (BPCs). In a swine aneurysm model, polyglycolide/polylactide (a polymer) …

Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study

Y Murayama, S Tateshima, NR Gonzalez, F Vinuela - Stroke, 2003 - Am Heart Assoc
Background and Purpose—Acceleration of intra-aneurysmal clot organization and fibrosis
may be a solution to preventing aneurysm recanalization after endovascular treatment. The …

Single-institution experience with matrix coils in the treatment of intracranial aneurysms: comparison with same-center outcomes with the use of platinum coils

DJ Rivet, CJ Moran, A Mazumdar… - American journal …, 2007 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: This study was undertaken to analyze the outcomes and
treatment-related complications of the polyglycolic/polylactic acid (PGLA)-coated Matrix …

A single centre study of coil embolization of intracranial aneurysms comparing bare platinum and PGLA-coated coils

RS Bose, RJ Dowling, B Yan, PJ Mitchell - Journal of Clinical Neuroscience, 2012 - Elsevier
There is no robust consensus on the efficacy of polyglycolic/polylactic acid (PGLA)-coated
coils used in the endovascular embolization of intracranial aneurysms. We present a …

Bare platinum vs matrix detachable coils for the endovascular treatment of intracranial aneurysms: a multivariate logistic regression analysis and review of the …

MJ Smith, J Mascitelli, A Santillan, JS Brennan… - …, 2011 - journals.lww.com
BACKGROUND: Despite increasing acceptance of endovascular coiling for treating
intracranial aneurysms, incomplete occlusion remains a limitation. Attempts to reduce …

Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry

L Pierot, A Bonafé, S Bracard… - American Journal of …, 2006 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Endovascular treatment of intracranial aneurysms by
using detachable coils has become an accepted alternative to surgery. To reduce the rate of …