Radiation dose to the lens using different temporal bone CT scanning protocols

Y Niu, Z Wang, Y Liu, Z Liu… - American journal of …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical
practice. At the same time, the eye lens are exposed to ionizing radiation without any useful …

Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose

S Suzuki, S Furui, T Ishitake, T Abe… - American Journal …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Some recent studies on radiation lens injuries have
indicated much lower dose thresholds than specified by the current radiation protection …

Comparison of eye lens dose on neuroimaging protocols between 16-and 64-section multidetector CT: achieving the lowest possible dose

JSP Tan, KL Tan, JCL Lee, CM Wan… - American journal …, 2009 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: To our knowledge, there has been no study that compares
the radiation dose delivered to the eye lens by 16-and 64-section multidetector CT (MDCT) …

Radiation dose of the eye lens in CT examinations of the brain in clinical practice—the effect of radiographer training to optimise gantry tilt and scan length

J Tarkiainen, M Nadhum, A Heikkilä… - Radiation Protection …, 2023 - academic.oup.com
Lenses are always exposed to radiation in brain computed tomography (CT) scans.
However, the lens dose can be reduced by excluding lens from scanning area by optimising …

Radiation dose and risk to the lens of the eye during CT examinations of the brain

R Poon, MK Badawy - Journal of medical imaging and …, 2019 - Wiley Online Library
Cataracts are the leading cause of blindness and visual disability worldwide. Of the known
contributing factors to this condition, ionising radiation is considered the primary concern in …

Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms

U Nikupaavo, T Kaasalainen… - American journal of …, 2015 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to study different optimization methods for
reducing eye lens dose in head CT. MATERIALS AND METHODS. Two anthropomorphic …

Estimation of radiation-induced cataract and cancer risks during routine CT head procedures

M Alkhorayef, A Sulieman, B Alonazi… - Radiation Physics and …, 2019 - Elsevier
Eye lenses lie within the radiation field during computed tomography (CT) procedures of the
brain. Therefore, patients are at risk of forming eye lens opacity when exposures exceed the …

Radiation doses to the eye lenses in computed tomography of the orbit and the petrous bone

KF Neufang, FE Zanella… - European journal of …, 1987 - pubmed.ncbi.nlm.nih.gov
Standard CT examinations of the orbit and the petrous bone were simulated with a tissue-
equivalent human skull phantom on a Somatom DR 2 scanner. The orientation of the scan …

[PDF][PDF] Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth …

CWK Lai, HY Cheung, TP Chan, TH Wong - Radioprotection, 2015 - scholar.archive.org
Objective: Computed Tomography (CT) is the leading contributor to medical exposure to
ionizing radiation. Although the use of CT brain scans for patients with head injuries and …

Image quality and radiation exposure in 320-row temporal bone computed tomography

HC Bauknecht, E Siebert, A Dannenberg… - Dentomaxillofacial …, 2010 - academic.oup.com
Objectives: The aim was to define image quality and radiation exposure in the recently
introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods …