Radiation dose to the lens using different temporal bone CT scanning protocols
Y Niu, Z Wang, Y Liu, Z Liu… - American journal of …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Temporal bone CT is performed frequently in clinical
practice. At the same time, the eye lens are exposed to ionizing radiation without any useful …
practice. At the same time, the eye lens are exposed to ionizing radiation without any useful …
Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose
S Suzuki, S Furui, T Ishitake, T Abe… - American Journal …, 2010 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: Some recent studies on radiation lens injuries have
indicated much lower dose thresholds than specified by the current radiation protection …
indicated much lower dose thresholds than specified by the current radiation protection …
Comparison of eye lens dose on neuroimaging protocols between 16-and 64-section multidetector CT: achieving the lowest possible dose
JSP Tan, KL Tan, JCL Lee, CM Wan… - American journal …, 2009 - Am Soc Neuroradiology
BACKGROUND AND PURPOSE: To our knowledge, there has been no study that compares
the radiation dose delivered to the eye lens by 16-and 64-section multidetector CT (MDCT) …
the radiation dose delivered to the eye lens by 16-and 64-section multidetector CT (MDCT) …
Radiation dose of the eye lens in CT examinations of the brain in clinical practice—the effect of radiographer training to optimise gantry tilt and scan length
J Tarkiainen, M Nadhum, A Heikkilä… - Radiation Protection …, 2023 - academic.oup.com
Lenses are always exposed to radiation in brain computed tomography (CT) scans.
However, the lens dose can be reduced by excluding lens from scanning area by optimising …
However, the lens dose can be reduced by excluding lens from scanning area by optimising …
Radiation dose and risk to the lens of the eye during CT examinations of the brain
R Poon, MK Badawy - Journal of medical imaging and …, 2019 - Wiley Online Library
Cataracts are the leading cause of blindness and visual disability worldwide. Of the known
contributing factors to this condition, ionising radiation is considered the primary concern in …
contributing factors to this condition, ionising radiation is considered the primary concern in …
Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms
U Nikupaavo, T Kaasalainen… - American journal of …, 2015 - Am Roentgen Ray Soc
OBJECTIVE. The purpose of this study was to study different optimization methods for
reducing eye lens dose in head CT. MATERIALS AND METHODS. Two anthropomorphic …
reducing eye lens dose in head CT. MATERIALS AND METHODS. Two anthropomorphic …
Estimation of radiation-induced cataract and cancer risks during routine CT head procedures
Eye lenses lie within the radiation field during computed tomography (CT) procedures of the
brain. Therefore, patients are at risk of forming eye lens opacity when exposures exceed the …
brain. Therefore, patients are at risk of forming eye lens opacity when exposures exceed the …
Radiation doses to the eye lenses in computed tomography of the orbit and the petrous bone
KF Neufang, FE Zanella… - European journal of …, 1987 - pubmed.ncbi.nlm.nih.gov
Standard CT examinations of the orbit and the petrous bone were simulated with a tissue-
equivalent human skull phantom on a Somatom DR 2 scanner. The orientation of the scan …
equivalent human skull phantom on a Somatom DR 2 scanner. The orientation of the scan …
[PDF][PDF] Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth …
Objective: Computed Tomography (CT) is the leading contributor to medical exposure to
ionizing radiation. Although the use of CT brain scans for patients with head injuries and …
ionizing radiation. Although the use of CT brain scans for patients with head injuries and …
Image quality and radiation exposure in 320-row temporal bone computed tomography
HC Bauknecht, E Siebert, A Dannenberg… - Dentomaxillofacial …, 2010 - academic.oup.com
Objectives: The aim was to define image quality and radiation exposure in the recently
introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods …
introduced 320-row CT of the temporal bone (tb) in comparison to a 16-row tb CT. Methods …
Related searches
- lens of the eye radiation dose
- clinical practice radiation dose
- temporal bone radiation exposure
- temporal bone image quality
- temporal bone computed tomography
- examinations of the brain radiation dose
- radiographer training radiation dose
- bismuth shield radiation dose
- petrous bone radiation doses
- gantry tilt radiation dose
- scan length radiation dose
- combined use radiation dose
- computed tomography radiation doses
- clinical practice eye lens
- routine head lens dose
- anthropomorphic phantoms lens dose