Clinical trial of iotrol for lumbar myelography.

T Skutta, H Vogelsang, M Galanski… - American Journal …, 1983 - Am Soc Neuroradiology
Iotrol, a new nonionic, water-soluble, hexiodinated dimeric contrast medium for
myelography, was used in clinical trials in 29 patients. The purpose of the study was to …

Comparative clinical study with iotrolan versus metrizamide in lumbar myelography.

S Inoue, T Watanabe, H Yamamura - Fortschritte auf dem Gebiete …, 1989 - europepmc.org
In order to examine the radiopacity, safety, and usefulness of iotrolan, a new dimeric,
nonionic, water-soluble contrast medium for myelography, a multicenter clinical study was …

Iotrolan, a nonionic dimeric contrast medium in myelography.

S Bien, M Schumacher, W Berger… - Fortschritte auf dem …, 1989 - europepmc.org
As part of a clinical Phase III study of the nonionic, dimeric contrast medium iotrolan,
differences in opacification, tolerance, and effects on the electroencephalogram after …

Iotrol versus metrizamide in lumbar myelography: a double-blind study.

MD Malnor, LW Houston, CM Strother, PA Turski… - Radiology, 1986 - pubs.rsna.org
In a prospective, randomized, double-blind study, 49 patients underwent lumbar
myelography using iotrol (24 patients) or metrizamide (25 patients). The diagnostic imaging …

Iotrolan versus iopamidol: a controlled, multicenter, double-blind study of lumbar and direct cervical myelography.

K Ringel, E Klotz, BI Wenzel-Hora - Fortschritte auf dem Gebiete der …, 1989 - europepmc.org
Iotrolan is a new nonionic, dimeric contrast medium that is distinguished by its special
physicochemical and low chemotoxic properties. It displays near isotonicity with blood and …

A prospective comparison of iotrolan and iohexol in lumbar myelography

A Wagner, C Jensen, A Saebye… - Acta …, 1994 - journals.sagepub.com
In a double-blind study 238 patients were examined with lumbar myelography using iotrolan
or iohexol in randomized sequence in order to evaluate the image quality, the safety and …

A prospective comparison of iotrolan, iohexol and iopamidol for lumbar myelography.

J Lamb, V McAllister, M Nelson, R Bartlett… - Acta radiologica …, 1986 - europepmc.org
The provisional results are presented of a comparative blind trial of iotrolan, iohexol and
iopamidol for lumbar myelography. The aim of the trial was to assess the relative safety …

Iohexol versus metrizamide for lumbar myelography: double-blind trial

TO Gabrielsen, SS Gebarski, JE Knake… - American journal of …, 1984 - Am Roentgen Ray Soc
Lumbar myelography was performed in 50 patients; 25 received iohexol (an investigational
aqueous contrast agent) and 25 received metrizamide. The two media produced …

Iohexol versus metrizamide for lumbar myelography: preliminary report of double-blind trial

SS Gebarski, TO Gabrielsen, JE Knake, JT Latack… - …, 1984 - journals.lww.com
Lumbar myelography was performed in 38 patients; 19 received iohexol (an investigational
aqueous contrast agent) and 19 received metrizamide. Iohexol is stable in solution, which is …

Tolerance of iohexol, iopamidol, and metrizamide in lumbar myelography

CM Elkin, AMT Levan, NE Leeds - Surgical neurology, 1986 - Elsevier
Iohexol and iopamidol, two new nonionic contrast media, have been extensively studied in
comparison with metrizamide for lumbar myelography. Review of the literature with statistical …