Deflation of detachable balloons in the cavernous sinus by percutaneous puncture.
JM Jacobs, GD Parker… - American journal of …, 1993 - Am Soc Neuroradiology
The authors show that percutaneous puncture of balloons within the cavernous sinus is
technically feasible and allows further access to the cavernous sinus after balloon …
technically feasible and allows further access to the cavernous sinus after balloon …
[PDF][PDF] New detachable balloon technique for traumatic carotid-cavernous sinus fistulae.
W Taki, H Handa, H Miyake… - AJNR: American …, 1985 - Am Soc Neuroradiology
Recent advances in intravascular surgery have opened new horizons in the treatment of
various cerebrovascular diseases. In particular, embolization using detachable balloon …
various cerebrovascular diseases. In particular, embolization using detachable balloon …
Treatment of traumatic carotid-cavernous fistula using detachable balloon catheters.
GM Debrun - American Journal of Neuroradiology, 1983 - Am Soc Neuroradiology
The goal of therapy in patients with traumatic carotid-cavernous fistulas is to occlude the
fistula, preferably while maintaining the carotid blood flow. Surgical techniques that treat the …
fistula, preferably while maintaining the carotid blood flow. Surgical techniques that treat the …
[PDF][PDF] Unilateral double carotid cavernous fistula treated with detachable balloons.
G Wilms - AJNR: American Journal of Neuroradiology, 1990 - Am Soc Neuroradiology
Discussion The cavernous part of the internal carotid artery, fixed to the surrounding dura at
the base of the skull, is exposed to shearing stresses (1]. In blunt orbital trauma, such …
the base of the skull, is exposed to shearing stresses (1]. In blunt orbital trauma, such …
Carotid-cavernous fistula: closure with detachable silicone balloons.
D Norman, TH Newton, MS Edwards, V DeCaprio - Radiology, 1983 - pubs.rsna.org
Detachable silicone rubber balloons, which do not require an outer catheter to effect
detachment, were used to close carotid-cavernous fistulas in 10 patients. Closure was …
detachment, were used to close carotid-cavernous fistulas in 10 patients. Closure was …
A safe technique for the precise localization of carotid-cavernous fistula during balloon obliteration
HL Cares, GH Roberson, W Grand… - Journal of Neurosurgery, 1978 - thejns.org
✓ The authors report a technique to precisely localize a fistulous opening in the carotid
artery. The patient is heparinized and a Prolo catheter is introduced into the internal carotid …
artery. The patient is heparinized and a Prolo catheter is introduced into the internal carotid …
Intraluminal occlusion of a carotid-cavernous sinus fistula with a balloon catheter
DJ Prolo, JW Hanbery - Journal of neurosurgery, 1971 - thejns.org
✓ A technique for intraluminal occlusion of a carotid-cavernous sinus fistula with a balloon
catheter is described. Passage of a balloon catheter into the cavernous carotid artery from …
catheter is described. Passage of a balloon catheter into the cavernous carotid artery from …
Deflation of metrizamide-filled balloon used to occlude a carotid-cavernous fistula: Case report
TJ Leipzig, SF Mullan - Journal of neurosurgery, 1983 - thejns.org
✓ A carotid-cavernous fistula was occluded by a detachable latex balloon. Because of
technical problems, the contrast-filled balloon was left in a precarious position in the ostium …
technical problems, the contrast-filled balloon was left in a precarious position in the ostium …
Complete obliteration of a carotid cavernous fistula with sparing of the carotid blood flow using a detachable balloon catheter.
SB Fierstien, D DeFeo, A Nutkiewicz - Surgical neurology, 1978 - europepmc.org
Complete obliteration of a carotid cavernous fistula with sparing of the carotid blood flow using
a detachable balloon catheter. - Abstract - Europe PMC Sign in | Create an account …
a detachable balloon catheter. - Abstract - Europe PMC Sign in | Create an account …
Carotid-cavernous fistula. Intravascular treatment with a self-sealing detachable balloon.
HS Ahn, RI White Jr, AJ Kumar, MH Epstein… - Radiology, 1983 - pubs.rsna.org
Five traumatic carotid-cavernous fistulas were treated using a new self-sealing, detachable,
silicone-rubber balloon, as part of a balloon-catheter system, and a modified technique for …
silicone-rubber balloon, as part of a balloon-catheter system, and a modified technique for …