Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in
  • Log out

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in
  • Log out

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Abstract

Endovascular treatment of fusiform aneurysms with stents and coils: technical feasibility in a swine model.

T F Massoud, F Turjman, C Ji, F Viñuela, G Guglielmi, Y P Gobin and G R Duckwiler
American Journal of Neuroradiology November 1995, 16 (10) 1953-1963;
T F Massoud
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
F Turjman
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C Ji
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
F Viñuela
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G Guglielmi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y P Gobin
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G R Duckwiler
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

PURPOSE To assess the biomechanical feasibility of treating experimental fusiform aneurysms endovascularly with a combination of stents and coils.

METHODS An experimental model was surgically constructed in the necks of nine swine to simulate intracranial fusiform aneurysms possessing important "perforators" or side branches. Balloon-expandable metal stents were positioned across the aneurysms in eight swine. In five of these, additional treatment was intraaneurysmal placement of detachable microcoils. Attempts were made to deposit these coils strategically away from the origin of the side branch.

RESULTS Stent placement was successful in seven swine but failed in one swine because of stent-aneurysm size mismatch. Two swine treated with only stents showed no significant alterations in blood filling of the aneurysm or side branch. Satisfactory coil placement (outside the stent, within the aneurysm sac, and away from the orifice of the side branch) was achieved in four of the five swine treated with stents and coils. Careful fluoroscopic monitoring and controlled coil delivery were necessary to avoid covering the sidebranch origin. These aneurysms could not be packed densely after detachment of the first coil because of the resultant radiographic overlap of multiple coil loops on the stent and its lumen in all projections. In one swine there was inadvertent untoward reentry of the coil tip into the expanded stent lumen during its delivery.

CONCLUSION Endovascular treatment of experimental fusiforms aneurysms using stents and coils is technically feasible. The stent maintains patency of the parent artery while allowing strategic coil placement in the aneurysm sac away from the origin of side branches. This technique may prove useful in the future treatment of intracranial fusiform aneurysms. However, potential sources of technical difficulties have been identified, and further longterm studies using an appropriate intracranial stent will be necessary before human application.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 16, Issue 10
1 Nov 1995
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Endovascular treatment of fusiform aneurysms with stents and coils: technical feasibility in a swine model.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Endovascular treatment of fusiform aneurysms with stents and coils: technical feasibility in a swine model.
T F Massoud, F Turjman, C Ji, F Viñuela, G Guglielmi, Y P Gobin, G R Duckwiler
American Journal of Neuroradiology Nov 1995, 16 (10) 1953-1963;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Endovascular treatment of fusiform aneurysms with stents and coils: technical feasibility in a swine model.
T F Massoud, F Turjman, C Ji, F Viñuela, G Guglielmi, Y P Gobin, G R Duckwiler
American Journal of Neuroradiology Nov 1995, 16 (10) 1953-1963;
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Reduction of Coil Mass Artifacts in High-Resolution Flat Detector Conebeam CT of Cerebral Stent-Assisted Coiling
  • Stent-Assisted Coiling of Bifurcation Aneurysms May Improve Endovascular Treatment: A Critical Evaluation in an Experimental Model
  • Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device
  • Stent-Assisted Reconstructive Endovascular Repair of Cranial Fusiform Atherosclerotic and Dissecting Aneurysms: Long-Term Clinical and Angiographic Follow-Up
  • Development of Gold Stents for the Treatment of Intracranial Aneurysms: An Experimental Study in a Canine Model
  • Treatment of Wide-Necked Intracranial Aneurysms with a Self-Expanding Stent System: Initial Clinical Experience
  • Endovascular Problem Solving with Intravascular Stents
  • INTERVENTIONAL NEURORADIOLOGY
  • Percutaneous Treatment of Abdominal Aortic Aneurysm in a Swine Model : Understanding the Behavior of Aortic Aneurysm Closure Through a Serial Histopathological Analysis
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire