Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in
  • Log out

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in
  • Log out

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Research ArticleExpedited PublicationE

Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms

J.P. Cruz, M. Chow, C. O'Kelly, B. Marotta, J. Spears, W. Montanera, D. Fiorella and T. Marotta
American Journal of Neuroradiology April 2012, 33 (4) 603-608; DOI: https://doi.org/10.3174/ajnr.A3065
J.P. Cruz
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Chow
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. O'Kelly
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
B. Marotta
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Spears
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W. Montanera
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Fiorella
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Marotta
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: The PED is a flow-diverting stent designed for the treatment of cerebral aneurysms. We report 4 cases of delayed ipsilateral IPH following the technically successful treatment of anterior circulation aneurysms with the PED.

MATERIALS AND METHODS: Clinical and imaging data from all patients undergoing aneurysm treatment with the PED at 2 institutions were analyzed to assess the incidence of delayed IPH after treatment with the PED.

RESULTS: A total of 66 patients (47 anterior circulation) with cerebral aneurysms underwent treatment with a PED between January 2008 and November 2010. Four patients experienced delayed periprocedural IPH, all after the treatment of anterior circulation aneurysms (8.5%, 4/47). The aneurysm size ranged from 5 to 21 mm. All IPHs occurred within the cerebral hemisphere, ipsilateral to the treated aneurysm, and were anatomically remote from the treated aneurysms. All procedures were uncomplicated, and patients emerged from general anesthesia at neurologic baseline. The hemorrhages became clinically evident between 1 and 6 days after the procedure. Two patients had unfavorable outcomes (mRS scores, 4 and 6).

CONCLUSIONS: Delayed IPH may occur after the treatment of anterior circulation aneurysms with flow diverters. This complication does not seem to be restricted to a specific aneurysm subtype and does not seem to be related to an intraprocedural complication or solely attributable to DAT.

ABBREVIATIONS:

DAT
dual antiplatelet therapy
FD
flow diversion
IPH
intraparenchymal hemorrhage
IQR
interquartile range
mRS
modified Rankin Scale
PED
Pipeline Embolization Device

Flow diverters have recently received full European Conformity Mark approval for commercialization within the European Union and FDA approval for their use within the United States. To date, the reported periprocedural and midterm follow-up results have been extremely impressive,1⇓⇓⇓–5 with very high rates of complete aneurysm occlusion and relatively low rates of postoperative morbidity and mortality. However, as more experience is accrued, their potential limitations and optimal applications are becoming increasingly evident.6⇓⇓⇓⇓⇓–12

We report 4 cases of delayed ipsilateral IPH following the treatment of anterior circulation aneurysms with the PED.

Materials and Methods

Data Collection

All patients treated with the PED (ev3/Covidian, Irvine, California) between January 2008 and November 2010 at 2 different institutions were included. All available clinical and neuroimaging data were reviewed. Specifically, each case was reviewed for the occurrence of postprocedural IPH. The aneurysm size and location, procedural details, clinical presentation at the time of IPH diagnosis, subsequent imaging, and clinical outcome at last follow-up were evaluated.

PED Procedures

In general, all patients were pretreated with both aspirin (325 mg) and clopidogrel (600-mg loading dose or 75 mg daily for a minimum of 5 days) before treatment. No tests of in vitro platelet function for clopidogrel clinical response and dosing were used. One patient with hemorrhage underwent stent placement on clopidogrel only. Aspirin was introduced gradually with a desensitization protocol during the immediate postprocedural period. All procedures were performed with the patient under general anesthesia. Procedural heparinization was used to achieve a targeted activated clotting time ranging between 250 and 300s. A transfemoral access was used with either a 6F guiding catheter or 6F long sheath. Following angiographic evaluation of the targeted aneurysms, including rotational angiography, a 0.027-inch microcatheter (Marksman, ev3/Covidian) was manipulated across the targeted landing zone over a standard 0.014-inch microguidewire. Once in position, PEDs were delivered to reconstruct the parent artery defect, with multiple partially overlapping devices used as needed to bridge normal arterial segments or achieve the desired flow effect. Following stent delivery, control angiography was performed in the working angles for treatment as well as in a branch vessel projection.

Statistical Analysis

Demographic data and aneurysm size are expressed in medians and IQRs, given the small sample size.

Results

A total of 66 patients (47 anterior circulation) with cerebral aneurysms underwent treatment with the PED between January 2008 and November 2010. Of these, 4 patients experienced delayed periprocedural IPH. These included 3 females and 1 male (median age, 60 years; IQR, 15.75 years). Two patients were heavy smokers; 2 patients had well-controlled hypertension.

Aneurysm Characteristics

All hemorrhages occurred after the treatment of anterior circulation aneurysms (4 of 47 cases; 8.5%). These aneurysms involved the proximal MCA (n = 1) (Fig 1) or supraclinoid segment of the ICA (n = 3) (Figs 2⇓–4). Median aneurysm size was 9.5 mm (IQR, 4.75 mm). One of the larger aneurysms demonstrated a fusiform morphology. Three aneurysms were previously treated (1 clipped, 1 coiled, 1 PED) (Table).

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

A, Right ICA anteroposterior angiogram showing a previously clipped right M1 segment aneurysm with a large recurrence. B, Immediate post-PED deployment appearance. Note the amount of contrast stasis within the aneurysm sac. C, NCCT 1 day after the procedure shows a right frontal lobar hematoma emptying into the ventricle with no significant midline shift. The patient presented with a left hemiplegia, which fully recovered on subsequent follow-up.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Left ICA lateral angiogram with a small broad neck supraclinoid saccular aneurysm pre- (A) and post-PED deployment (B). Coils from a previously treated basilar tip aneurysm are seen (asterisk). NCCT (C) and DWI MR imaging (D) sequences show a subcortical frontal hematoma and subcortical small ischemic lesions. Note the absence of a large associated cortical ischemic infarct.

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

A, Initial right ICA anteroposterior (AP) angiogram with a giant supraclinoid ICA aneurysm before PED deployment (the stent is collapsed within the microcatheter). Right ICA AP angiogram 3 months later, with persistent early aneurysm filling (asterisk) pre- (B) and postdeployment (C) of 2 more PEDs. The aneurysm sac showed significant interval enlargement and development of a daughter bleb (images not shown), so a new PED was placed to increase the flow effect. D, NCCT 1 day later shows a large acute right lobar hematoma with significant mass effect. The patient survived with a persistent left attenuated hemiparesis.

Fig 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 4.

A, Left ICA lateral angiogram showing the previously coiled supraclinoid aneurysm with a significant residual filling. B, Single-shot lateral image with the PED fully deployed covering the neck of the aneurysm (arrows). C, DWI 48 hours later shows multiple left cortical ischemic lesions. D, NCCT 6 days later shows a large left frontal lobar hematoma, emptying into the ventricle, with marked midline shift and mass effect. The patient died 24 hours late.

View this table:
  • View inline
  • View popup

Patients who presented with ipsilateral IPH after treatment with the PED

Intraparenchymal Hemorrhage Characteristics and Neuroimaging

All IPHs occurred within the cerebral hemisphere ipsilateral to the treated aneurysm (3 frontal lobe, 1 temporal lobe). Hemorrhages ranged in largest diameter from 36 to 72 mm (median, 59 mm; IQR, 24.75 mm). All hemorrhages were anatomically remote from the treated aneurysms. A review of the operative reports and procedural imaging by the operators did not reveal any specific intraprocedural details to which the hemorrhages could be attributed. Two of the 4 patients with hemorrhage had MR imaging–DWI either before or after the hemorrhage. In both patients, several small embolic infarcts were distributed within the ipsilateral cerebral hemisphere.

Clinical Course

All procedures were technically successful and uncomplicated. All patients emerged from general anesthesia at neurologic baseline and remained well during the immediate postoperative period. Blood pressure was closely monitored in an intensive care unit in the early postoperative period. The hemorrhages became clinically evident between 1 and 6 days after the procedure (median, 1.5 days; IQR, 2). Three patients presented with hemiplegia or hemiparesis; 1 patient presented with loss of consciousness. One patient fully recovered, 1 has slight disability, 1 has moderate/severe disability, and 1 patient died.

Discussion

Delayed Ipsilateral IPH: A Complication Related to the Treatment of Anterior Circulation Aneurysms with Flow Diversion?

Although the hemorrhages were anatomically remote from the treated aneurysms, several factors support the conclusion that these are related (in some way) to the FD procedure. First, although all procedures were technically successful and the patients emerged from anesthesia neurologically intact, all hemorrhages occurred during the immediate periprocedural (<24 hours) or early postprocedural period (days). Second, all the IPHs occurred in the vascular distribution of the reconstructed vascular segment. If a spontaneous IPH could potentially occur within either the ipsilateral hemisphere, the contralateral hemisphere, or the posterior circulation distribution, the odds of 4 consecutive IPH events occurring by chance within the ipsilateral hemisphere would be 1/3 to the fourth power or 1/81 (1.2%). Third, the rate (8.5%) at which IPH was observed in our series far exceeded that which would be expected as a sequela of dual antiplatelet therapy alone.13 For example, the annual risk of major parenchymal hemorrhage is 1.1%–1.8% in patients with DAT for secondary stroke prevention.14

The rate of IPH in this series (8.5%) is higher than the 2.2% reported after stent-assisted coiling.15 A detailed analysis of a cohort of 284 patients treated with the Neuroform stent (Boston Scientific, Natick, Massachusetts) showed a 1.1% (3/284) rate of spontaneous IPH >48 hours after treatment.16 Most interesting, the 3 delayed hemorrhages observed were equally distributed relative to the reconstructed vascular segment: 1 ipsilateral, 1 contralateral, and 1 within the posterior circulation after treatment of an anterior circulation aneurysm. These data would suggest that ipsilateral postprocedural IPH might be a phenomenon that is somehow uniquely associated with flow-diverting devices.

Delayed Ipsilateral IPH Does Not Appear to Be Related to the Size or Morphology of the Treated Lesion

The aneurysms that went on to postprocedural hemorrhage ranged widely in size, configuration, and previous treatments (Table), unlike the process of mural destabilization and delayed rupture, which appears to be almost exclusive of very large and giant aneurysms.8,10,17 As such, this complication, if consistently observed, may limit the use of the PED in aneurysms amenable for other treatment modalities with a lower overall morbidity and mortality.18⇓⇓⇓–22

Putative Etiology of Delayed Ipsilateral Parenchymal Hemorrhage after Flow Diversion

Due to the early stage of the clinical application of the FD technique and the uncharacterized but apparently low incidence of this phenomenon, the available data on which to base a mechanistic hypothesis are scant.

An initial consideration was that these hemorrhages were related to intraprocedural microwire perforations; however, this explanation was discarded for several reasons. First, the hemorrhages, though ipsilateral, were primarily lobar, distal to the aneurysms, and not consistently in a distribution that would be concordant with the intraprocedural location of the microwire. Second, all occurred at least 1 day after the index procedure, which would not be compatible with procedural vascular perforation that typically becomes clinically obvious within the first few hours.

Another consideration would be hemorrhagic transformation of clinically silent small periprocedural embolic infarcts seen in the 2 patients who had postprocedure MR imaging, as proposed by Fischer et al.23 A number of studies have quantified the incidence of small clinically silent periprocedural DWI lesions after endovascular procedures, demonstrating that such lesions are not uncommon,24⇓⇓–27 but so far, to our knowledge, no reports documenting the postprocedural hemorrhagic transformation of these types of lesions exist, even in the setting of DAT.

Our proposed hypothesis is that the reconstruction of the flexible arteries of the carotid siphon with the PED could reduce the local compliance of that vascular segment, altering the “Windkessel effect,” changing the blood pressure waveform transmitted to the distal cerebrovasculature28,29—that is, if segmental vascular reconstruction with the PED reduces arterial compliance, the blood pressure waveform transmitted beyond the reconstructed segment might exhibit a higher systolic peak and a lower diastolic trough (ie, a larger pulse pressure), and this alteration could contribute to delayed postprocedural ipsilateral IPH.30 The standard method to measure vessel wall compliance is the echo-tracking system,31 but no devices exist for intracranial vessels. Devices to measure in vivo vessel wall compliance with optical coherence elastography are under development,32 as well as noninvasive image-based computer models.33 These may allow measuring the changes in the vessel wall elasticity and comparing these changes among the different intracranial stents.

We acknowledge several limitations of our series. The sample size is small, with a heterogeneous group of aneurysm types, which precludes any statistical analysis for potential risk factors; but at the same time, this case series shows that this phenomenon is not exclusive to a specific subtype of lesion. Also, no in vitro platelet function test was used to measure the level of platelet antiaggregation, but the clinical utility in determining clopidogrel clinical response and dosing of commercially available tests is still controversial.34,35 Also, the conducted trials in the cardiology literature are designed to measure reduction in thromboembolic events.36 To our knowledge, no reports on “over-antiplatelet inhibition” and increased hemorrhagic complications have been reported in the endovascular literature.

Conclusions

Delayed ipsilateral IPH may occur after the treatment of anterior circulation aneurysms with flow diverters. This phenomenon appears independent of aneurysm size, morphology, or anatomic complexity and does not seem to be directly related to an intraprocedural event (eg, a distal wire perforation). As such, no factors have been identified that might allow operators to prospectively identify patients who might be at risk for this complication.

Footnotes

  • Paper previously presented as a Flash Presentation (3 minutes long, 5 slides) at: Annual Meeting of the World Federation of Interventional and Therapeutic Neuroradiology, Cape Town, South Africa; November 8, 2011.

  • Disclosures: Cian James O'Kelly—UNRELATED: Other: proctor fee, Comments: reimbursement for providing proctoring assistance with PED cases. David Fiorella—RELATED: Consulting Fee or Honorarium: ev3, Covidien, Comments: Pipeline proctoring (reimbursed for travel expenses only), ev3 paid consultant ($10,000), Fees for Participation in Review Activities (such as data monitoring boards, statistical analysis, end point committees, and the like): ev3, Covidien, Comments: Pipeline proctoring, UNRELATED: Consultancy: Codman Neurovascular, NFocus, WL Gore, Grants/Grants Pending: National Institutes of Health (Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis),* MicroVention/Terumo,* Siemens,* Payment for Lectures (including service on Speakers Bureaus): Codman Neurovascular, Micrus, MicroVention, ev3, Comments: Micrus-Codman-Johnson & Johnson: consulting, significant conflict ($10,000); MicroVention Terumo: consulting, significant conflict ($10,000), Patents (planned, pending, or issued): ReVasc Inc (acquired by Micrus/Codman Neurovascular), Royalties: ReVasc Inc (acquired by Micrus/Codman Neurovascular), Comments: significant conflict ($10,000), Payment for Development of Educational Presentations: Codman Neurovascular. Thomas R. Marotta—RELATED: Consulting Fee or Honorarium: proctoring for PED from ev3, Covidien, Comments: teaching other physicians how to use the device, UNRELATED: Consultancy: Evasc Medical Systems (Vancouver, British Columbia), Comments: some travel expenses, Patents (planned, pending, or issued): patent owner for eCLIPS endovascular flow diverter device. *Money paid to the institution.

References

  1. 1.↵
    1. Szikora I,
    2. Berentei Z,
    3. Kulcsar Z,
    4. et al
    . Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the Pipeline embolization device. AJNR Am J Neuroradiol 2010;31: 1139–47
    Abstract/FREE Full Text
  2. 2.↵
    1. Fiorella D,
    2. Woo HH,
    3. Albuquerque FC,
    4. et al
    . Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the Pipeline embolization device. Neurosurgery 2008;62: 1115–20,discussion 1120–21
    CrossRefPubMed
  3. 3.↵
    1. Fiorella D,
    2. Kelly ME,
    3. Albuquerque FC,
    4. et al
    . Curative reconstruction of a giant midbasilar trunk aneurysm with the Pipeline embolization device. Neurosurgery 2009;64: 212–17,discussion 217
    CrossRefPubMed
  4. 4.↵
    1. Lylyk P,
    2. Miranda C,
    3. Ceratto R,
    4. et al
    . Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 2009;64: 632–42, discussion 642–43, quiz N636
    CrossRefPubMed
  5. 5.↵
    1. D'Urso PI,
    2. Lanzino G,
    3. Cloft HJ,
    4. et al
    . Flow diversion for intracranial aneurysms: a review. Stroke 2011;42: 2363–68
    Abstract/FREE Full Text
  6. 6.↵
    1. Fiorella D,
    2. Hsu D,
    3. Woo HH,
    4. et al
    . Very late thrombosis of a Pipeline embolization device construct: case report. Neurosurgery 2010;67 (3 suppl operative): E313–14, discussion E314
  7. 7.↵
    1. Kulcsar Z,
    2. Berentei Z,
    3. Marosfoi M,
    4. et al
    . Thromboembolic complication induced stable occlusion of a ruptured basilar tip aneurysm: case report and review of the literature. Interv Neuroradiol 2010;16: 83–88
    Abstract/FREE Full Text
  8. 8.↵
    1. Turowski B,
    2. Macht S,
    3. Kulcsar Z,
    4. et al
    . Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts? Neuroradiology 2011;53: 37–41
    CrossRefPubMed
  9. 9.↵
    1. Kulcsar Z
    . Rupture of previously unruptured aneurysms after flow diversion treatment. In: Proceedings of the Anatomy-Biology-Clinical Correlations/Working Group in Interventional Neuroradiology Conference, Val d'Isere, France. January 10–15, 2010
  10. 10.↵
    1. Kulcsar Z,
    2. Houdart E,
    3. Bonafe A,
    4. et al
    . Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 2010;32: 20–25
    PubMed
  11. 11.↵
    1. Cebral JR,
    2. Mut F,
    3. Raschi M,
    4. et al
    . Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 2010;32: 27–33
    PubMed
  12. 12.↵
    1. Klisch J,
    2. Turk A,
    3. Turner R,
    4. et al
    . Very late thrombosis of flow-diverting constructs after the treatment of large fusiform posterior circulation aneurysms. AJNR Am J Neuroradiol 2011;32: 627–32
    Abstract/FREE Full Text
  13. 13.↵
    1. Serebruany VL,
    2. Malinin AI,
    3. Ferguson JJ,
    4. et al
    . Bleeding risks of combination vs. single antiplatelet therapy: a meta-analysis of 18 randomized trials comprising 129,314 patients. Fundam Clin Pharmacol 2008;22: 315–21
    CrossRefPubMed
  14. 14.↵
    1. Diener HC,
    2. Bogousslavsky J,
    3. Brass LM,
    4. et al
    . Aspirin and clopidogrel compared with clopidogrel alone after recent ischaemic stroke or transient ischaemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial. Lancet 2004;364: 331–37
    CrossRefPubMed
  15. 15.↵
    1. Shapiro M,
    2. Becske T,
    3. Sahlein D,
    4. et al
    . Stent-supported aneurysm coiling: a literature survey of treatment and follow-up. AJNR AM J Neuroradiol 2012;33: 159–63
    Abstract/FREE Full Text
  16. 16.↵
    1. Fiorella D,
    2. Albuquerque FC,
    3. Woo H,
    4. et al
    . Neuroform stent assisted aneurysm treatment: evolving treatment strategies, complications and results of long term follow-up. J Neurointerv Surg 2010;2: 16–22
    Abstract/FREE Full Text
  17. 17.↵
    1. Hampton T,
    2. Walsh D,
    3. Tolias C,
    4. et al
    . Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases. J Neurointerv Surg 2011;3: 167–71
    Abstract/FREE Full Text
  18. 18.↵
    1. King JT,
    2. Berlin JA,
    3. Flamm ES
    . Morbidity and mortality from elective surgery for asymptomatic, unruptured, intracranial aneurysms: a meta-analysis. J Neurosurg 1994;81: 837–42
    CrossRefPubMed
  19. 19.↵
    1. Lessne ML,
    2. Shah P,
    3. Alexander MJ,
    4. et al
    . Thromboembolic complications after Neuroform stent-assisted treatment of cerebral aneurysms: the Duke Cerebrovascular Center experience in 235 patients with 274 stents. Neurosurgery 2011;69: 369–75
    CrossRefPubMed
  20. 20.↵
    1. Naggara ON,
    2. White PM,
    3. Guilbert F,
    4. et al
    . Endovascular treatment of intracranial unruptured aneurysms: systematic review and meta-analysis of the literature on safety and efficacy. Radiology 2010;256: 887–97
    CrossRefPubMed
  21. 21.↵
    1. Orz YI,
    2. Hongo K,
    3. Tanaka Y,
    4. et al
    . Risks of surgery for patients with unruptured intracranial aneurysms. Surg Neurol 2000;53: 21–27, discussion 27–29
    CrossRefPubMed
  22. 22.↵
    1. Shapiro M,
    2. Babb J,
    3. Becske T,
    4. et al
    . Safety and efficacy of adjunctive balloon remodeling during endovascular treatment of intracranial aneurysms: a literature review. AJNR Am J Neuroradiol 2008;29: 1777–81
    Abstract/FREE Full Text
  23. 23.↵
    1. Fischer S,
    2. Vajda Z,
    3. Aguilar Perez M,
    4. et al
    . Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections. Neuroradiology 2012;54: 369–82
    CrossRefPubMed
  24. 24.↵
    1. Brooks NP,
    2. Turk AS,
    3. Niemann DB,
    4. et al
    . Frequency of thromboembolic events associated with endovascular aneurysm treatment: retrospective case series. J Neurosurg 2008;108: 1095–100
    CrossRefPubMed
  25. 25.↵
    1. Grunwald IQ,
    2. Papanagiotou P,
    3. Politi M,
    4. et al
    . Endovascular treatment of unruptured intracranial aneurysms: occurrence of thromboembolic events. Neurosurgery 2006;58: 612–18, discussion 612–18
    CrossRefPubMed
  26. 26.↵
    1. Rordorf G,
    2. Bellon RJ,
    3. Budzik RE,
    4. et al
    . Silent thromboembolic events associated with the treatment of unruptured cerebral aneurysms by use of Guglielmi detachable coils: prospective study applying diffusion-weighted imaging. AJNR Am J Neuroradiol 2001;22: 5–10
    Abstract/FREE Full Text
  27. 27.↵
    1. Soeda A,
    2. Sakai N,
    3. Sakai H,
    4. et al
    . Thromboembolic events associated with Guglielmi detachable coil embolization of asymptomatic cerebral aneurysms: evaluation of 66 consecutive cases with use of diffusion-weighted MR imaging. AJNR Am J Neuroradiol 2003;24: 127–32
    Abstract/FREE Full Text
  28. 28.↵
    1. Safar ME,
    2. Blacher J,
    3. Mourad JJ,
    4. et al
    . Stiffness of carotid artery wall material and blood pressure in humans: application to antihypertensive therapy and stroke prevention. Stroke 2000;31: 782–90
    Abstract/FREE Full Text
  29. 29.↵
    1. Dobson G,
    2. Flewitt J,
    3. Tyberg JV,
    4. et al
    . Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs. Eur J Vasc Endovasc Surg 2006;32: 129–35
    CrossRefPubMed
  30. 30.↵
    1. Velat GJ,
    2. Fargen KM,
    3. Lawson MF,
    4. et al
    . Delayed intraparenchymal hemorrhage following Pipeline embolization device treatment for a giant recanalized ophthalmic aneurysm. J Neurointerv Surg 2011 Sep 27. [Epub ahead of print]
  31. 31.↵
    1. Vayssettes-Courchay C,
    2. Ragonnet C,
    3. Isabelle M,
    4. et al
    . Aortic stiffness in vivo in hypertensive rat via echo-tracking: analysis of the pulsatile distension waveform. Am J Physiol Heart Circ Physiol 2011;301: H382–90
    Abstract/FREE Full Text
  32. 32.↵
    1. Sun C,
    2. Standish B,
    3. Yang VX
    . Optical coherence elastography: current status and future applications. J Biomed Opt 2011;16: 043001
  33. 33.↵
    1. Taylor CA,
    2. Steinman DA
    . Image-based modeling of blood flow and vessel wall dynamics: applications, methods and future directions—Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28–30, 2008 Pasadena, California. Ann Biomed Eng 2010;38: 1188–203
    CrossRefPubMed
  34. 34.↵
    1. Price MJ,
    2. Berger PB,
    3. Teirstein PS,
    4. et al
    . Standard- vs high-dose clopidogrel based on platelet function testing after percutaneous coronary intervention: the GRAVITAS randomized trial. JAMA 2011;305: 1097–105
    CrossRefPubMed
  35. 35.↵
    1. Comin J,
    2. Kallmes D
    . Clopidogrel (Plavix). AJNR Am J Neuroradiol 2011;32: 2002–04
    Abstract/FREE Full Text
  36. 36.↵
    1. Brar SS,
    2. ten Berg J,
    3. Marcucci R,
    4. et al
    . Impact of platelet reactivity on clinical outcomes after percutaneous coronary intervention: a collaborative meta-analysis of individual participant data. J Am Coll Cardiol 2011;58: 1945–54
    CrossRefPubMed
  • Received November 23, 2011.
  • Accepted after revision January 25, 2012.
  • © 2012 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 33 (4)
American Journal of Neuroradiology
Vol. 33, Issue 4
1 Apr 2012
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms
J.P. Cruz, M. Chow, C. O'Kelly, B. Marotta, J. Spears, W. Montanera, D. Fiorella, T. Marotta
American Journal of Neuroradiology Apr 2012, 33 (4) 603-608; DOI: 10.3174/ajnr.A3065

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms
J.P. Cruz, M. Chow, C. O'Kelly, B. Marotta, J. Spears, W. Montanera, D. Fiorella, T. Marotta
American Journal of Neuroradiology Apr 2012, 33 (4) 603-608; DOI: 10.3174/ajnr.A3065
Reddit logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Computational Fluid Dynamics Using a Porous Media Setting Predicts Outcome after Flow-Diverter Treatment
  • Downstream vascular changes after flow-diverting device deployment in a rabbit model
  • Middle cerebral artery flow velocity increases more in patients with delayed intraparenchymal hemorrhage after Pipeline
  • Flow Diversion in Ruptured Intracranial Aneurysms: A Meta-Analysis
  • Concomitant coiling reduces metalloproteinase levels in flow diverter-treated aneurysms but anti-inflammatory treatment has no effect
  • Use of flow diverters in the treatment of unruptured saccular aneurysms of the anterior cerebral artery
  • Carotid cavernous fistula after Pipeline placement: a single-center experience and review of the literature
  • Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: mid-term results
  • Treatment of experimental aneurysms with a new liquid embolic agent and a retrievable stent: proof of concept and feasibility study
  • Current Trends and Results of Endovascular Treatment of Unruptured Intracranial Aneurysms at a Single Institution in the Flow-Diverter Era
  • Retrospective Analysis of Delayed Intraparenchymal Hemorrhage after Flow-Diverter Treatment: Presentation of a Retrospective Multicenter Trial
  • Effect of antiplatelet therapy and platelet function testing on hemorrhagic and thrombotic complications in patients with cerebral aneurysms treated with the pipeline embolization device: a review and meta-analysis
  • Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device
  • Periprocedural and mid-term technical and clinical events after flow diversion for intracranial aneurysms
  • Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device
  • Treatment of a dissecting vertebral artery aneurysm with angioplasty and the pipeline embolisation device
  • Prospective Study of Early MRI Appearances following Flow-Diverting Stent Placement for Intracranial Aneurysms
  • Extra-Aneurysmal Flow Modification Following Pipeline Embolization Device Implantation: Focus on Regional Branches, Perforators, and the Parent Vessel
  • Endovascular treatment with flow diverters of recanalized and multitreated aneurysms initially treated by endovascular approach
  • International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment Study
  • Heterogeneous practice patterns regarding antiplatelet medications for neuroendovascular stenting in the USA: a multicenter survey
  • Platelet function inhibitors and platelet function testing in neurointerventional procedures
  • Effect of Structural Remodeling (Retraction and Recoil) of the Pipeline Embolization Device on Aneurysm Occlusion Rate
  • Balloon Occlusion Tests and Therapeutic Vessel Occlusions Revisited: When, When Not, and How
  • Endovascular Treatment of Middle Cerebral Artery Aneurysms with Flow Modification with the Use of the Pipeline Embolization Device
  • Advances in Stroke: Advances in Interventional Radiology 2013
  • Last-Recorded P2Y12 Reaction Units Value Is Strongly Associated with Thromboembolic and Hemorrhagic Complications Occurring Up to 6 Months after Treatment in Patients with Cerebral Aneurysms Treated with the Pipeline Embolization Device
  • Incidence of Microemboli and Correlation with Platelet Inhibition in Aneurysmal Flow Diversion
  • Cerebral hyperperfusion after flow diversion of large intracranial aneurysms
  • Distant and Delayed (>7 Days) Hemorrhage after Treatment by Flow-Diverter Stents in Intracranial Aneurysms: A Rare but Potentially Serious Complication
  • Endovascular Treatment of Intracranial Aneurysms: Current Status
  • Canadian Experience with the Pipeline Embolization Device for Repair of Unruptured Intracranial Aneurysms
  • Pipeline Embolization Device in Aneurysmal Subarachnoid Hemorrhage
  • Endovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis
  • Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device
  • Cerebral hyperperfusion after flow diversion of large intracranial aneurysms
  • Revisiting the Risk of Intraparenchymal Hemorrhage following Aneurysm Treatment by Flow Diversion
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • MRI Findings in Children with Acute Flaccid Paralysis and Cranial Nerve Dysfunction Occurring during the 2014 Enterovirus D68 Outbreak
  • MRI Surrogates for Molecular Subgroups of Medulloblastoma
  • WEB-DL Endovascular Treatment of Wide-Neck Bifurcation Aneurysms: Short- and Midterm Results in a European Study
Show more EXPEDITED PUBLICATION

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire