Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

ReplyLETTER

Reply:

R.K.S. Rathore and R.K. Gupta
American Journal of Neuroradiology May 2013, 34 (5) E60; DOI: https://doi.org/10.3174/ajnr.A3578
R.K.S. Rathore
aDepartment of Mathematics and Statistics Indian Institute of Technology, Kanpur, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R.K. Gupta
bDepartment of Radiology and Imaging Fortis Memorial Research Institute Gurgaon, India
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site

We thank Paula Alcaide-Leon and Álex Rovira for their interest in our work.1 In a given a time-series model involving a number of parameters, it is reasonable to expect that a determination of the parameters by using very few time points may result in erroneous estimates due to noise in the data. However, if one uses enough time points, the computations are expected to be relatively error-free; the inclusion of too many time points need not result in any better estimates.

Furthermore, if the model describes the data (ie, it is applicable), the variability in the parameter estimates using variable time points should only be random. A systematic variation in estimated parameter with respect to variable time points is indicative of an inadequacy of the model to describe the data.

The generalized tracer kinetic model (GTKM) given by Formula is a 2-compartment model used by the commenting authors.

To resolve the persistence of uptake, researchers are using a model that assumes unidirectional exchange (ie, from the capillary plasma to the extracellular extravascular space [EES]2⇓–4), which essentially consists of the Patlak model: Formula describing a pure contrast uptake voxel.

The actual situation, however, appears to be best described by the 3-compartment leaky tracer kinetic model (LTKM)5: Formula presented in Rathore et al6,7 and Sahoo et al.8

LTKM reduces to GTKM if the leakage space is absent (λtr = 0); and it reduces to the Patlak model in the absence of a permeable space (ktr = 0).

The systematic variability of the tracer kinetic parameters using GTKM and its cessation using LTKM is considered at length in Sahoo et al.5

In short, it not necessary to prolong the observations until the washout phase, and a study of approximately 3 minutes is quite adequate. What is needed is to use the correct model in which the constancy of the parameters is restored to its original state. For further discussion of LTKM, readers may refer to Sahoo et al.5

We used only an in-house-developed code for our computations.

References

  1. 1.
    1. Gupta RK,
    2. Awasthi R,
    3. Garg RK,
    4. et al
    . T1-weighted dynamic contrast-enhanced MR evaluation of different stages of neurocysticercosis and its relationship with serum MMP-9 expression. AJNR Am J Neuroradiol 2012 Nov 22. [Epub ahead of print]
  2. 2.
    1. Sourbron SP,
    2. Buckley DL
    . Tracer kinetic modeling in MRI: estimating perfusion and capillary permeability. Phys Med Biol 2012;57:R1–33
  3. 3.
    1. Li KL,
    2. Zhu XP,
    3. Checkley DR,
    4. et al
    . Simultaneous mapping of blood volume and endothelial permeability surface area product in gliomas using iterative analysis of first-pass dynamic contrast enhanced MRI data. Br J Radiol 2003;76:39–50
  4. 4.
    1. Patlak CS,
    2. Blasberg RG,
    3. Fenstermacher JD
    . Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 1983;3:1–7
  5. 5.
    1. Sahoo P,
    2. Rathore RK,
    3. Awasthi R,
    4. et al
    . Subcompartmentalization of extracellular extravascular space (EES) into permeability and leaky space with local arterial input function (AIF) results in improved discrimination between high- and low-grade glioma using dynamic contrast-enhanced (DCE) MRI. J Magn Reson Imaging 2013 Feb 6. [Epub ahead of print]
  6. 6.
    1. Rathore RKS,
    2. Sahoo P,
    3. Awasthi R,
    4. et al
    . A modified generalized tracer kinetic model for perfusion parameters in DCE-MRI for high grade intracranial mass lesions. In: Proceedings of the Nineteenth Annual Meeting of the International Society of Magnetic Resonance in Medicine, Montreal, Quebec, Canada; May 6–13, 2011
  7. 7.
    1. Rathore RKS,
    2. Gupta RK,
    3. Sahoo P,
    4. et al
    . DCE-MRI using a three compartment leaky tracer kinetic model (LTKM) for whole body applications. In: Proceedings of the Twentieth Annual Meeting of the International Society of Magnetic Resonance in Medicine, Melbourne, Australia; May 5–11, 2012
  8. 8.
    1. Sahoo P,
    2. Awasthi R,
    3. Rathore RKS,
    4. et al
    . Effects of AIF selection and pharmacokinetic model selection on discrimination of chronic infective from chronic inflammatory knee arthritis using DCE-MRI. In: Proceedings of the Twentieth Annual Meeting of the International Society of Magnetic Resonance in Medicine. Melbourne, Australia; May 5–11, 2012
  • © 2013 by American Journal of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire