Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

LetterLETTER

ASPECTS Distorts Infarct Volume Measurement

R.A. Suss and M.C. Pinho
American Journal of Neuroradiology May 2020, 41 (5) E28; DOI: https://doi.org/10.3174/ajnr.A6485
R.A. Suss
aDepartment of RadiologyUniversity of Texas Southwestern Medical CenterDallas, Texas
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.A. Suss
M.C. Pinho
aDepartment of RadiologyUniversity of Texas Southwestern Medical CenterDallas, Texas
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M.C. Pinho

Sundaram et al1 reported lucidly on agreements and correlations of ASPECTS for NCCT (manual, automatic) and CTP-CBV (manual). But why use ASPECTS, not volume?

Invented as a volume surrogate, ASPECTS takes the form of “content analysis”—a research method to quantify texts and symbols,2 wherein ASPECTS unitizes the MCA territory by defining 10 regions and categorizes each unit as having either no or any acute infarction. Measurement is degraded by the unitization’s vague definitions and diverse volumes, the binary categorization of so few units, and the bias of “any.” ASPECTS promotes interobserver disagreement (masked by “auto-”) and scatters markedly away from true volume. It is not excused for individual patient use by mere population correlation. Moreover, ASPECTS tends to advance infarcts by sometimes large margins of error beyond a supposed threshold of risk or futility, denying thrombectomy. A detailed explanation of ASPECTS and its flaws and a quick remediation by manual volumetry using the diameter formula ABC/2 (or a PACS-friendly refinement called 2Sh/3) are available.3

Besides the well-documented ABC/2 and 2Sh/3, the software behind any auto-ASPECTS can, in principle, report infarct volumes. If these and other authors skip ASPECTS and use volume, their agreements and correlations might be stronger and their plots less scattered.

Footnotes

  • Disclosures: Marco C. Pinho—UNRELATED: Consultancy: ABC Medical Education, Comments: On-line educational activities related to MRI.

References

  1. 1.
    1. Sundaram VK,
    2. Goldstein J,
    3. Wheelwright D, et al
    . Automated ASPECTS in acute ischemic stroke: a comparative analysis with CT perfusion. AJNR Am J Neuroradiol 2019;40:2033–38 doi:10.3174/ajnr.A6303 pmid:31727750
  2. 2.
    1. Krippendorff K
    . Content Analysis: An Introduction to its Methodology, 4th ed. Los Angeles: Sage Publications; 2019
  3. 3.
    1. Suss RA
    . ASPECTS, the mismeasure of stroke: a metrological investigation. OSF Preprints 2019 https://doi.org/10.31219/osf.io/c4tkp. Accessed December 31, 2019
  • © 2020 by American Journal of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire