Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticleInterventional

Efficacy and Safety of Flow Diversion for Paraclinoid Aneurysms: A Matched-Pair Analysis Compared with Standard Endovascular Approaches

G. Lanzino, E. Crobeddu, H.J. Cloft, R. Hanel and D.F. Kallmes
American Journal of Neuroradiology December 2012, 33 (11) 2158-2161; DOI: https://doi.org/10.3174/ajnr.A3207
G. Lanzino
aFrom the Departments of Neurosurgery (G.L., E.C.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Crobeddu
aFrom the Departments of Neurosurgery (G.L., E.C.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H.J. Cloft
bRadiology (H.J.C., D.F.K.), Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Hanel
cDepartment of Neurosurgery (R.H.), Mayo Clinic, Jacksonville, Florida.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.F. Kallmes
bRadiology (H.J.C., D.F.K.), Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Flow diversion is a new strategy for the treatment of complex paraclinoid aneurysms. However, flow diverters have, to date, not been tested in direct comparison with other available treatments. We present a matched-pair comparison of paraclinoid aneurysms treated with the PED versus other endovascular techniques.

MATERIALS AND METHODS: Twenty-one eligible patients with 22 paraclinoid aneurysms treated with the PED at our institution were matched with historic controls with aneurysms of similar size and location.

RESULTS: There were no statistically significant differences between the 2 groups in terms of aneurysm size, location, risk factors, or comorbidities. Mean dome size was 13.9 ± 6.7 mm in the control group and 14.9 ± 6.3 mm in the PED group (P = .52). Balloon and stent assistance were used in 31.8% and 9.1% of controls, respectively, while carotid sacrifice was used in 36.4% of the controls. There was a significant difference in the rate of complete occlusion favoring PED at radiologic follow-up (P = .03).

CONCLUSIONS: Flow diverters achieve a much higher rate of complete angiographic obliteration compared with other standard endovascular techniques in the treatment of internal carotid artery aneurysms. In this series, this higher angiographic obliteration rate did not occur at the expense of an increased rate of complications. Careful long-term follow-up is of the utmost importance to definitively validate flow diversion as a superior therapeutic strategy for proximal internal carotid artery aneurysms.

ABBREVIATIONS:

PED
Pipeline Embolization Device
PUFS
Pipeline Embolization Device for Uncoilable or Failed Aneurysms

Flow diversion has been proposed as a new strategy in the treatment of complex intracranial aneurysms.1,2 In April 2011, the FDA approved the PED (Chestnut Medical Technologies, Menlo Park, California) for treatment of large wide-neck aneurysms arising from the ICA proximally to the takeoff of the posterior communicating artery. Several single-center series3⇓⇓–6 and a few multicenter retrospective and prospective studies have demonstrated the efficacy and relative safety of these devices.7⇓⇓⇓–11 However, flow diverters have not, to date, been tested in direct comparison with other available treatments. In the current study, we conducted a retrospective matched-pair comparison of paraclinoid aneurysms treated with the PED versus other endovascular techniques.

Materials and Methods

The study was approved by the local institutional review board. The Pipeline Embolization Device was available at our institution as of June 2009, and since then, we have maintained a prospective data base with information regarding patient age, symptomatic status, location and size of the aneurysm, number of devices used, length of hospital stay, and early and late technical and clinical complications. Every patient had a scheduled follow-up angiogram at least 6 months following treatment. Patients were excluded from this study if the aneurysm was localized in segments other than the ICA proximal to the takeoff of the posterior communicating artery or if the patients had not yet reached a 6-month follow-up point. Every eligible patient treated with the PED was matched to a historic control patient with an aneurysm of similar size and location as well as with a similar history of previous or no previous treatment of the aneurysm (surgical or endovascular).

Given the relatively small number of patients who fulfilled the criteria set up for the study, we did not incur in any situation in which >1 match was available for a given patient treated with the PED. Information regarding control aneurysms was obtained from our data base of aneurysms treated with endovascular techniques since 1999.

Index cases and controls were also matched for the length of radiologic follow-up, though in the control group, radiologic follow-up included either DSA or MRA. Location of the index aneurysm was classified according to the classification proposed by Bouthillier et al.12 Aneurysm occlusion was graded by using the 3-point modified Raymond scale.13 Continuous data are presented as mean ± SD. Categoric data were compared with the χ2 or Fisher exact test. The Wilcoxon rank sum test and the Student t test were used to compare continuous data between 2-level categoric variables. Univariate logistic regression models were assessed, and odds ratios (95% confidence intervals) are reported. Results were considered significant for P values ≤.05. All statistical analyses were performed with JMP software, Version 9.0.1 (SAS Institute, Cary, North Carolina).

Results

Twenty-one patients were treated with the PED. Among these, all patients had available 6-month follow-up angiography and 13 patients had available 12-month angiography. Basic demographic characteristics and risk factors between the 2 groups are summarized in Table 1. There were no statistically significant differences between the 2 groups in terms of aneurysm size, location, risk factors, and comorbidities, though there was a trend for patients in the control group to be older and, as a consequence, to have a higher incidence of hypertension. In each group, there were 3 (13.6%) giant aneurysms (≥25 mm), 12 (54.5%) large (11–24 mm), and 7 (31.8%) small aneurysms. All the aneurysms treated had a wide neck (>4 mm). Carotido-ophthalmic aneurysms were the most common (54.5%), followed by intracavernous aneurysms (40.9%) and superior hypophyseal aneurysms (4.5%). Mean dome size was 13.9 ± 6.7 mm in the control group and 14.9 ± 6.3 mm in the PED group (P = .52). Characteristics of aneurysms are summarized in Table 2. Balloon and stent assistance were used in 31.8% and 9.1% of controls, respectively, while carotid sacrifice was used in 36.4% of the controls (Table 3).

View this table:
  • View inline
  • View popup
Table 1:

Demographic features of patients

View this table:
  • View inline
  • View popup
Table 2:

Main features of aneurysms

View this table:
  • View inline
  • View popup
Table 3:

Treatment modality

The mean length of stay was not significantly different between the 2 groups (2.2 ± 1.9 days for control group and 1.6 ± 0.9 days in the PED group, P = .41). Technical and access periprocedural complications are listed in Table 4. Periprocedural clinical complications in the PED group included gastrointestinal bleed for 1 patient (4.5%) and transient worsening of ophthalmoparesis (4.5%) and a groin hematoma that required surgical repair for another one (4.5%), while the control group included transient right weakness of upper and lower extremities (4.5%, solved spontaneously, without evidence of stroke) and hemodynamic instability (4.5%, for a patient who had a retroperitoneal hematoma).

View this table:
  • View inline
  • View popup
Table 4:

Clinical and technical complications

There was a significant difference in the rate of complete occlusion favoring PED at radiologic follow-up (P = .03) (Table 5). One patient in the PED group was found to have an asymptomatic ICA occlusion diagnosed at a routine 6-month follow-up study. No stenosis within the device was observed in any of the patients treated with PED. Late clinical complications included 1 patient who started having episodes consistent with amaurosis fugax 22 months after treatment with the PED. These resolved after reinstitution of antiplatelet therapy.

View this table:
  • View inline
  • View popup
Table 5:

Degree of obliteration at radiologic follow-up

After excluding the 8 patients who underwent carotid sacrifice and the patient treated with PED who was found to have an asymptomatic carotid occlusion, 21.4% of controls versus 76.2% of patients treated with PED were found to have complete aneurysm exclusion (P = .0014) (Table 6). In the control group, patients treated with arterial preservation were treated with coils alone (7 patients, 50.0%), balloon-assisted coiling (5 patients, 35.7%), and stent-assisted coiling (2 patients, 14.3%). Carotid sacrifice in the control group was achieved by using coils in 6 patients and balloons in the remaining 2.

View this table:
  • View inline
  • View popup
Table 6:

Degree of occlusiona

Discussion

In this retrospective matched-pair analysis, we found a significantly higher incidence of complete occlusion at follow-up in patients treated with the PED compared with similar aneurysms matched for size and location that were treated with other “conventional” endovascular techniques. In the PED group, by using very strict angiographic criteria, complete occlusion on DSA was achieved in three-quarters of patients, while such occlusion was achieved in less than one-half of patients treated by conventional means. Notably, rates of adverse events were similar between groups. These results suggest strongly that flow diversion might improve long-term angiographic outcomes in patients with “difficult” aneurysms in the periophthalmic region and may offer substantial benefit over other endovascular options.

The incomplete degree of angiographic obliteration and the risk of aneurysm recurrence have been the main limitations of endovascular treatment of intracranial aneurysms. These limitations have been the impetus behind the modifications of the coil (such as bioactive coils, coating with expandable materials like hydrogel, and so forth) and the development of microcatheter-delivered stents to be used in stent-assisted coiling procedures. Despite these advances, the recurrence rate and the rate of incomplete angiographic obliteration after aneurysm treatment with “modified” or “biologically” active coils and stent-assisted coiling continue to be discouragingly high.14,15 Flow diverters may fill the need for a more effective and definitive endovascular treatment, especially as it applies to paraclinoid aneurysms. Flow diverters seem to have multiple theoretic and some demonstrated properties that may increase the degree of angiographic obliteration and, with time, promote aneurysm shrinkage.16,17 By redirecting flow into the parent artery and away from the aneurysm sac, flow diverters induce progressive aneurysm thrombosis leading to angiographic obliteration with time. As the clot organizes and retracts, aneurysm shrinkage ensues.18⇓⇓–21 Moreover, the presence of the flow diverters in the aneurysm neck provides structural support of the “diseased” portion of the vessel, and with time as the device is incorporated into the vessel wall, it is covered by an endothelial layer that “seals” the neck.22,23

The high rate of complete angiographic occlusion at follow-up that we have observed is in line with that in other studies, though other studies did not have a control group. The PUFS study is the study that eventually led to FDA approval of the PED.10 In this multicenter prospective study, only giant and large aneurysms of the proximal ICA with wide necks were included. In PUFS, the rate of complete angiographic obliteration was 82% at 6 months and 86% at 1 year (T. Becske for the PUFS investigators, presented in Colorado Springs, July 2011, unpublished data). Lylyk et al,5 in a large single-center consecutive series of 54 patients, reported rates of complete angiographic obliteration of 56%, 93%, and 95% of aneurysms at 3, 6, and 12 months, respectively. Our data are similar to those in these prior reports, with high rates of complete occlusion; we have added important additional information in that we included similar types and sizes of aneurysm treated by other endovascular means so that practitioners can better assess the relative merits of flow diversion compared with coil embolization or parent artery sacrifice.

Treatment with flow diverters is particularly effective in aneurysms involving the proximal internal carotid artery. These aneurysms have a “sidewall” geometry, which makes them more suitable for these treatment paradigms. Proximal ICA aneurysms often have a fusiform shape with involvement of the entire circumference of the vessel, which makes them less suitable for effective treatment with other conventional endovascular techniques. In our study, 36.4% of the controls had been treated with parent artery sacrifice. While parent artery sacrifice is a well-established and effective treatment technique for aneurysms of the proximal internal carotid artery, several limitations of this approach exist. These are related to the risk of flow-related aneurysm formation along the collateral pathways and to the decrease in cerebrovascular reserve after 1 carotid artery has been sacrificed. Moreover, because proximal carotid aneurysms are often related to an “intrinsic” weakness of the vessel wall in this segment, patients with these aneurysms often have contralateral aneurysms or are at high risk of developing contralateral mirror aneurysms, which makes carotid artery sacrifice a less appealing option.

The effectiveness of flow diverters has to be weighed against their safety. In our study, complications with flow diverters were not significantly different from those in controls, and in the PED group, no patient had a permanent neurologic deterioration. Other studies have also confirmed the relative safety of these devices, despite the complexity of aneurysms treated. In the PUFS study, the rate of major ipsilateral stroke or neurologic death was 5.6%, while the intracranial hemorrhage rate was 4.7%.10 Midterm safety is also confirmed by our and other studies.3,5,8,9 We did not observe new permanent neurologic deficits after a mean follow-up of 13.4 ± 6.9 months, and only 1 patient had episodes possibly consistent with amaurosis fugax 22 months after treatment. These episodes resolved after reinstitution of antiplatelet therapy. The durability of the device is also confirmed in our study because only 1 patient had an asymptomatic internal carotid artery occlusion and no hemodynamically significant (>50%) stenosis was observed at 6 months in any of the patients or at 12 months in 13 patients who reached this follow-up milestone. In the PUFS study, stenosis of >50% occurred in 2 patients (1.9%) and 1 patient (1%) was found to have an asymptomatic ICA occlusion at the 6-month follow-up. Delayed aneurysm rupture (usually within the first 2 weeks of treatment) and distal hemorrhages have been reported after treatment with flow diverters and are one of the major concerns of this technology. No such events were observed in this series, and the causes leading to these feared and often devastating complications are still mostly unknown.

Our study has limitations. While the data for patients in the PED group were collected prospectively, data for the controls were retrospectively collected. Moreover, patients in the PED group were treated during the past 2 years, while controls had been treated across a longer and earlier interval and increased experience may have accounted for some of the better results seen with the PED. However, this effect would have been partially counteracted by the steep learning curve for the PED. While every patient in the PED group had at least 1 control DSA at follow-up, radiologic follow-up consisted of MRA in 14 (66.7%) patients in the control group, but this, if anything, should skew the results against the PED because MRA is not as sensitive as DSA in depicting persistent flow within the aneurysm. These limitations notwithstanding, our study is the only study comparing results of flow diversion with results of treating similar aneurysms with other endovascular techniques, to our knowledge.

Conclusions

Flow diverters achieve a much higher rate of complete angiographic obliteration compared with other standard endovascular techniques in the treatment of internal carotid artery aneurysms. In this series, this higher angiographic obliteration rate did not occur at the expense of an increased rate of complications. Flow diversion has largely supplanted advanced endovascular techniques such as balloon-assisted and stent-assisted coiling and has decreased significantly the need for parent artery sacrifice in the treatment of complex internal carotid artery aneurysms. Careful long-term follow-up is of utmost importance to definitively validate flow diversion as a superior therapeutic strategy for proximal internal carotid artery aneurysms.

Footnotes

  • Disclosures: Giuseppe Lanzino—UNRELATED: Educational Grants: ev3,* Synthes.* Harry J. Cloft—UNRELATED: Grants/Grants Pending: Cordis.* Ricardo Hanel—RELATED: Consultancy:Support for Travel to Meetings for the Study or Other Purposes: Codman, ev3, UNRELATED: Consultancy: NeuroVasx. David F. Kallmes—RELATED: Grant: ev3,* Comments: funding for clinical trials and preclinical research, Support for Travel to Meetings for the Study or Other Purposes: ev3,* Other: ev3,* Comments: preparation of education materials, UNRELATED: Grants/Grants Pending: Penumbra,* MircoVention,* Micrus,* Cordis,* Royalties: University of Virginia Patent Foundation, Comments: spine fusion; Payment for Development of Educational Presentations: ev3;* Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: MicroVention.* *Money paid to the institution

References

  1. 1.↵
    1. D'Urso PI,
    2. Lanzino G,
    3. Cloft HJ,
    4. at el
    . Flow diversion for intracranial aneurysms: a review. Stroke 2011;42:2363–68
    Abstract/FREE Full Text
  2. 2.↵
    1. Fiorella D,
    2. Lylyk P,
    3. Szikora I,
    4. et al
    . Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms. J Neurointerv Surg 2009;1:56–65
    Abstract/FREE Full Text
  3. 3.↵
    1. Aurboonyawat T,
    2. Schmidt PJ,
    3. Piotin M,
    4. et al
    . A study of the first-generation Pipeline embolization device morphology using intraoperative angiographic computed tomography (ACT). Neuroradiology 2011;53:23–30
    CrossRefPubMed
  4. 4.↵
    1. Cebral JR,
    2. Mut F,
    3. Raschi M,
    4. et al
    . Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 2011;32:27–33
    Abstract/FREE Full Text
  5. 5.↵
    1. Lylyk P,
    2. Miranda C,
    3. Ceratto R,
    4. et al
    . Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 2009;64:632–42, discussion 642–43
    CrossRefPubMed
  6. 6.↵
    1. Toni F,
    2. Cirillo L,
    3. Battaglia S,
    4. et al
    . 3T MRI in the evaluation of brain aneurysms treated with flow-diverting stents: preliminary experience. Neuroradiol J 2009;22:588–99
    Abstract/FREE Full Text
  7. 7.↵
    1. Briganti F,
    2. Napoli M,
    3. Tortora F,
    4. et al
    . Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications—a retrospective data analysis. Neuroradiology 2012;54:1145–52
    CrossRefPubMed
  8. 8.↵
    1. Byrne JV,
    2. Beltechi R,
    3. Yarnold JA,
    4. et al
    . Early experience in the treatment of intra-cranial aneurysms by endovascular flow diversion: a multicentre prospective study. PLoS One 2010;5:pii:e12492
    CrossRef
  9. 9.↵
    1. Lubicz B,
    2. Collignon L,
    3. Raphaeli G,
    4. et al
    . Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke 2010;41:2247–53
    Abstract/FREE Full Text
  10. 10.↵
    1. Nelson PK,
    2. Lylyk P,
    3. Szikora I,
    4. et al
    . The Pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol 2011;32:34–40
    Abstract/FREE Full Text
  11. 11.↵
    1. Szikora I,
    2. Berentei Z,
    3. Kulcsar Z,
    4. et al
    . Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the Pipeline embolization device. AJNR Am J Neuroradiol 2010;31:1139–47
    Abstract/FREE Full Text
  12. 12.↵
    1. Bouthillier A,
    2. van Loveren HR,
    3. Keller JT
    . Segments of the internal carotid artery: a new classification. Neurosurgery 1996;38:425–32, discussion 432–33
    CrossRefPubMed
  13. 13.↵
    1. Roy D,
    2. Milot G,
    3. Raymond J
    . Endovascular treatment of unruptured aneurysms. Stroke 2001;32:1998–2004
    Abstract/FREE Full Text
  14. 14.↵
    1. Crobeddu E,
    2. Lanzino G,
    3. Kallmes,
    4. et al
    . Review of 2 decades of aneurysm recurrence literature, Part 1: Reducing recurrence after endovascular coiling. AJNR Am J Neuroradiol 2012 Mar 29. [Epub ahead of print]
  15. 15.↵
    1. Crobeddu E,
    2. Lanzino G,
    3. Kallmes DF,
    4. et al
    . Review of 2 decades of aneurysm recurrence literature, Part 2: Managing recurrence after endovascular coiling. AJNR Am J Neuroradiol 2012 Mar 15. [Epub ahead of print]
  16. 16.↵
    1. Wakhloo AK,
    2. Lylyk P,
    3. Hartman M,
    4. et al
    . A new generation of flow-disruption device for endovascular treatment of intracranial aneurysms: preliminary clinical and angiographic results of a multicenter study. Stroke 2011;42:e100–e101
  17. 17.↵
    1. Wakhloo AK,
    2. Lanzino G,
    3. Lieber BB,
    4. et al
    . Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery 1998;43:377–79
    CrossRefPubMed
  18. 18.↵
    1. Aenis M,
    2. Stancampiano AP,
    3. Wakhloo AK,
    4. et al
    . Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 1997;119:206–12
    CrossRefPubMed
  19. 19.↵
    1. Kim M,
    2. Taulbee DB,
    3. Tremmel M,
    4. et al
    . Comparison of two stents in modifying cerebral aneurysm hemodynamics. Ann Biomed Eng 2008;36:726–41
    CrossRefPubMed
  20. 20.↵
    1. Kim YH,
    2. Xu X,
    3. Lee JS
    . The effect of stent porosity and strut shape on saccular aneurysm and its numerical analysis with lattice Boltzmann method. Ann Biomed Eng 2010;38:2274–92
    CrossRefPubMed
  21. 21.↵
    1. Sadasivan C,
    2. Cesar L,
    3. Seong J,
    4. et al
    . Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography. IEEE Trans Med Imaging 2009;28:1117–25
    CrossRefPubMed
  22. 22.↵
    1. Kallmes DF,
    2. Ding YH,
    3. Dai D,
    4. et al
    . A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 2007;38:2346–52
    Abstract/FREE Full Text
  23. 23.↵
    1. Kallmes DF,
    2. Ding YH,
    3. Dai D,
    4. et al
    . A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms. AJNR Am J Neuroradiol. 2009;30:1153–58
    Abstract/FREE Full Text
  • Received November 16, 2011.
  • Accepted after revision February 28, 2012.
  • © 2012 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 33 (11)
American Journal of Neuroradiology
Vol. 33, Issue 11
1 Dec 2012
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Efficacy and Safety of Flow Diversion for Paraclinoid Aneurysms: A Matched-Pair Analysis Compared with Standard Endovascular Approaches
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
G. Lanzino, E. Crobeddu, H.J. Cloft, R. Hanel, D.F. Kallmes
Efficacy and Safety of Flow Diversion for Paraclinoid Aneurysms: A Matched-Pair Analysis Compared with Standard Endovascular Approaches
American Journal of Neuroradiology Dec 2012, 33 (11) 2158-2161; DOI: 10.3174/ajnr.A3207

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Efficacy and Safety of Flow Diversion for Paraclinoid Aneurysms: A Matched-Pair Analysis Compared with Standard Endovascular Approaches
G. Lanzino, E. Crobeddu, H.J. Cloft, R. Hanel, D.F. Kallmes
American Journal of Neuroradiology Dec 2012, 33 (11) 2158-2161; DOI: 10.3174/ajnr.A3207
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Flow diversion for compressive unruptured internal carotid artery aneurysms with neuro-ophthalmological symptoms: a systematic review and meta-analysis
  • Flow diversion for compressive unruptured internal carotid artery aneurysms with neuro-ophthalmological symptoms: a systematic review and meta-analysis
  • The Safety and Efficacy of Flow Diversion versus Conventional Endovascular Treatment for Intracranial Aneurysms: A Meta-analysis of Real-world Cohort Studies from the Past 10 Years
  • Recovery from Cranial Nerve Symptoms after Flow Diversion without Coiling for Unruptured Very Large and Giant ICA Aneurysms
  • Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L)
  • Endovascular treatment of ophthalmic artery aneurysms: ophthalmic artery patency following flow diversion versus coil embolization
  • Current Trends and Results of Endovascular Treatment of Unruptured Intracranial Aneurysms at a Single Institution in the Flow-Diverter Era
  • Endovascular Treatment of Unruptured Paraclinoid Aneurysms: Single-Center Experience with 400 Cases and Literature Review
  • Therapeutic Internal Carotid Artery Occlusion for Large and Giant Aneurysms: A Single Center Cohort of 146 Patients
  • Flow Diversion versus Standard Endovascular Techniques for the Treatment of Unruptured Carotid-Ophthalmic Aneurysms
  • Endovascular coiling versus parent artery occlusion for treatment of cavernous carotid aneurysms: a meta-analysis
  • Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter Study
  • Flow Diversion Versus Conventional Treatment for Carotid Cavernous Aneurysms
  • A Single Pipeline Embolization Device is Sufficient for Treatment of Intracranial Aneurysms
  • Flow diversion versus traditional aneurysm embolization strategies: analysis of fluoroscopy and procedure times
  • Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
  • Extending the Indications of Flow Diversion to Small, Unruptured, Saccular Aneurysms of the Anterior Circulation
  • Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular Aneurysms
  • Crossref (90)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Comparison of Flow Diversion and Coiling in Large Unruptured Intracranial Saccular Aneurysms
    Nohra Chalouhi, Stavropoula Tjoumakaris, Robert M. Starke, L. Fernando Gonzalez, Ciro Randazzo, David Hasan, Jeffrey F. McMahon, Saurabh Singhal, Lea A. Moukarzel, Aaron S. Dumont, Robert Rosenwasser, Pascal Jabbour
    Stroke 2013 44 8
  • Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis
    Geng Zhou, Ming Su, Yan-Ling Yin, Ming-Hua Li
    Neurosurgical Focus 2017 42 6
  • Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter Study
    A. K. Wakhloo, P. Lylyk, J. de Vries, C. Taschner, J. Lundquist, A. Biondi, M. Hartmann, I. Szikora, L. Pierot, N. Sakai, H. Imamura, N. Sourour, I. Rennie, M. Skalej, O. Beuing, A. Bonafe, F. Mery, F. Turjman, P. Brouwer, E. Boccardi, L. Valvassori, S. Derakhshani, M. W. Litzenberg, M. J. Gounis
    American Journal of Neuroradiology 2015 36 1
  • Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
    N. Chalouhi, S. Tjoumakaris, L.F. Gonzalez, A.S. Dumont, R.M. Starke, D. Hasan, C. Wu, S. Singhal, L.A. Moukarzel, R. Rosenwasser, P. Jabbour
    American Journal of Neuroradiology 2014 35 3
  • Extending the Indications of Flow Diversion to Small, Unruptured, Saccular Aneurysms of the Anterior Circulation
    Nohra Chalouhi, Robert M. Starke, Steven Yang, Cory D. Bovenzi, Stavropoula Tjoumakaris, David Hasan, L. Fernando Gonzalez, Robert Rosenwasser, Pascal Jabbour
    Stroke 2014 45 1
  • Patency of the posterior communicating artery after flow diversion treatment of internal carotid artery aneurysms
    Waleed Brinjikji, Giuseppe Lanzino, Harry J. Cloft, David F. Kallmes
    Clinical Neurology and Neurosurgery 2014 120
  • Flow diversion in the treatment of aneurysms: a randomized care trial and registry
    Jean Raymond, Jean-Christophe Gentric, Tim E. Darsaut, Daniela Iancu, Miguel Chagnon, Alain Weill, Daniel Roy
    Journal of Neurosurgery 2017 127 3
  • Flow Diversion Versus Conventional Treatment for Carotid Cavernous Aneurysms
    Mario Zanaty, Nohra Chalouhi, Robert M. Starke, Guilherme Barros, Mark Philip Saigh, Eric Winthrop Schwartz, Norman Ajiboye, Stavropoula I. Tjoumakaris, David Hasan, Robert H. Rosenwasser, Pascal Jabbour
    Stroke 2014 45 9
  • A Single Pipeline Embolization Device is Sufficient for Treatment of Intracranial Aneurysms
    N. Chalouhi, S. Tjoumakaris, J. L. H. Phillips, R. M. Starke, D. Hasan, C. Wu, M. Zanaty, D. Kung, L. F. Gonzalez, R. Rosenwasser, P. Jabbour
    American Journal of Neuroradiology 2014 35 8
  • Endoscopic Endonasal Clipping of Intracranial Aneurysms: Surgical Technique and Results
    Paul A. Gardner, Francisco Vaz-Guimaraes, Brian Jankowitz, Maria Koutourousiou, Juan C. Fernandez-Miranda, Eric W. Wang, Carl H. Snyderman
    World Neurosurgery 2015 84 5

More in this TOC Section

  • SAVE vs. Solumbra Techniques for Thrombectomy
  • Contrast-Induced Encephalopathy after NeuroIR
  • CT Perfusion&Reperfusion in Acute Ischemic Stroke
Show more Interventional

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire