Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Brief ReportHEAD & NECK

MR Imaging Characteristics of Intraocular Perfluoro-n-Octane

M.T. Williams, J.E. Williams, B.A. Winegar, R.F. Carmody and J.B. Christoforidis
American Journal of Neuroradiology December 2020, DOI: https://doi.org/10.3174/ajnr.A6901
M.T. Williams
aFrom the Department of Ophthalmology and Vision Science (M.T.W., J.B.C.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M.T. Williams
J.E. Williams
cIra A. Fulton Schools of Engineering (J.E.W.), Arizona State University, Tempe, Arizona
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.E. Williams
B.A. Winegar
dDepartment of Radiology & Imaging Sciences (B.A.W.), University of Utah School of Medicine, Salt Lake City, Utah
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for B.A. Winegar
R.F. Carmody
bMedical Imaging (R.F.C.) University of Arizona College of Medicine, Tucson, Arizona
eRetina Specialists of Southern Arizona (R.F.C.), Tucson, Arizona.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.F. Carmody
J.B. Christoforidis
aFrom the Department of Ophthalmology and Vision Science (M.T.W., J.B.C.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.B. Christoforidis
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

SUMMARY: We describe the unique MR imaging characteristics of intraocular perfluoro-n-octane, a liquid used for intraoperative and postoperative tamponade in the context of complex retinal detachment repair, and contrast it with other intraocular pathologies. Because trace amounts of perfluoro-n-octane may be left in the globe postoperatively, it may be confused for other abnormalities, such as foreign bodies or tumors.

ABBREVIATION:

PFO
perfluoro-n-octane

Perfluoro-n-octane (PFO) is a low-viscosity perfluorocarbon liquid used for intraoperative retinal tamponade in complex retinal detachments.1 Its high specific gravity makes it useful for stabilizing and flattening the retina intraoperatively.1 PFO is thought to exert a long-term toxic effect on the retina, depending on the amount left in the eye, and typically at the end of the surgical procedure, it is exchanged with a perfluorocarbon gas or silicone oil for postoperative tamponade.1 The fluid–air exchange process is not perfect, and trace amounts of PFO may be left in the eye without consequence, except in rare cases when trace amounts of the liquid may be trapped in the subretinal space.2 There have been reports, however, of trace amounts of PFO mimicking intraocular foreign bodies on CT, thus prompting further unnecessary work-up when its history of use was unrecognized.3,4 Although its CT characteristics have been reported, its MR imaging characteristics have not been described to our knowledge.

In some cases, PFO may be intentionally left in the globe short term postoperatively for tamponade in eyes at high risk of re-detachment because of proliferative vitreoretinopathy or in patients with giant retinal tears or multiple inferior breaks who cannot tolerate face-down positioning.5 We describe here the MR imaging characteristics of PFO in a patient with a history of recurrent retinal detachments of the left eye requiring postoperative PFO tamponade who subsequently underwent MR imaging for unrelated vision loss of the right eye.

A 64-year-old male patient with a history of repair 2 weeks earlier of a recurrent rhegmatogenous retinal detachment of the left eye, complicated by proliferative vitreoretinopathy requiring PFO for postoperative tamponade, underwent MR imaging of the orbits (Figure) after presenting with vision loss of unclear cause of the right eye.

FIGURE.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE.

Axial T1-weighted (A), axial fat-suppressed T2-weighted (B), axial STIR (C), and sagittal T1-weighted (D) MR imaging of the orbits demonstrate hypointense PFO layering dependently within the posterior segment of the left globe (arrowheads) with fluid–fluid level (arrows). Note that the attenuation of PFO is greater than that of water, causing it to layer dependently within the left globe in this supine patient.

FINDINGS

PFO liquid demonstrates signal void on conventional fast spin-echo MR imaging, appearing hypointense on T1-weighted sequences, fat-suppressed T2-weighted sequences, and STIR sequences. In large quantities, the signal void of PFO on MR imaging resembles air. However, the high specific gravity of PFO accounts for its dependent layering when placed in the posterior segment, which is opposite of the nondependent layering of air and gaseous compounds.

DISCUSSION

The appearance of PFO on MR imaging results from its high specific gravity and lack of proton spins within the substance, leading to dependent layering and signal void on all sequences. The lack of proton spins owes to its chemical composition, C8F18, consisting entirely of carbon and fluorine atoms without any hydrogen atoms. In clinical contexts, PFO is most likely to be encountered in trace quantities. In these trace amounts, PFO could be mistaken for subhyaloid or retinal hemorrhage, air bubbles, dystrophic calcification, intraocular masses, or foreign bodies. Of the 5 substances injected into the globe for retinal tamponade, including filtered air, sulfur hexafluoride gas, perfluoropropane gas, silicone oil, and PFO, PFO is the only substance with a specific gravity higher than water and would be the only substance of the 5 expected to settle in a dependent manner. Silicone oil has been described as appearing similar to hemorrhage, demonstrating hyperintensity to vitreous on T1-weighted imaging and hypointensity on T2-weighted imaging.6

Intraocular masses, including uveal melanoma, intraocular metastases, retinoblastoma, and retinal capillary hemangioma, all demonstrate hypointensity to vitreous on T2-weighted images but are distinguishable from PFO by hyperintensity to vitreous on T1-weighted sequences or isointensity to vitreous on T1-weighted images in the case of metastases.7 Calcifications, which may be seen in phthisis bulbi, retinoblastoma, and optic disc drusen, would not feature fluid–fluid levels and typically take on a more disorganized or scattered appearance in the case of phthisis bulbi and retinoblastoma.8

Depending on their physical properties, intraocular foreign bodies can demonstrate a wide range of signal characteristics on MR imaging. Nonmetallic foreign bodies typically demonstrate low T1-weighted and T2-weighted signal intensity and may appear similar to PFO, especially if they are small.9 However, nonmetallic intraocular foreign bodies of larger size typically demonstrate geometric shapes without the fluid–fluid level appearance of PFO.9 Most nonmetallic intraocular foreign bodies also typically demonstrate a thin high-intensity rim most notable on T1-weighted images, with some foreign bodies, particularly certain types of glass and wood, also demonstrating variable blooming artifacts not seen with PFO.9

CONCLUSIONS

PFO may be differentiated from other intraocular entities by its signal void on all sequences, fluid–fluid levels when present in sufficient quantity, and dependent layering in the globe, owing to its high specific gravity. Multiple cases have been reported of trace amounts being confused for intraocular foreign bodies on CT, and if unrecognized, it may prompt further unnecessary work-up.3,4 In cases of repair of ocular trauma, both silicone oil droplets and PFO droplets have been reported to migrate intracranially, potentially leading to further diagnostic confusion.10,11 Knowledge of its MR imaging characteristics compared with other intraocular entities is important to avoid incorrect diagnosis.

References

  1. 1.↵
    1. Chang S,
    2. Sparrow JR,
    3. Iwamoto T, et al
    . Experimental studies of tolerance to intravitreal perfluoro-n-octane liquid. Retina 1991;11:367–74 pmid:1813951
    PubMed
  2. 2.↵
    1. Garcia-Valenzuela E,
    2. Ito Y,
    3. Abrams GW
    . Risk factors for retention of subretinal perfluorocarbon liquid in vitreoretinal surgery. Retina 2004;24:746–52 doi:10.1097/00006982-200410000-00010 pmid:15492629
    CrossRefPubMed
  3. 3.↵
    1. Christoforidis JB,
    2. Caruso PA,
    3. Curtin HD, et al
    . CT characteristics of intraocular perfluoro-N-octane. AJNR Am J Neuroradiol 2003;24:1769–71 pmid:14561600
    Abstract/FREE Full Text
  4. 4.↵
    1. Baskaran P,
    2. Ganne P,
    3. Krishnappa NC
    . Perfluoro-n-octane mimicking an intraocular foreign body. GMS Ophthalmol Cases 2017;7:Doc30 doi:10.3205/oc000081 pmid:29326862
    CrossRefPubMed
  5. 5.↵
    1. Rush R,
    2. Sheth S,
    3. Surka S, et al
    . Postoperative perfluoro-N-octane tamponade for primary retinal detachment repair. Retina 2012;32:1114–20 doi:10.1097/IAE.0b013e31822f56f6 pmid:21968506
    CrossRefPubMed
  6. 6.↵
    1. Mathews VP,
    2. Elster AD,
    3. Barker PB, et al
    . Intraocular silicone oil: in vitro and in vivo MR and CT characteristics. AJNR Am J Neuroradiol 1994;15:343–47 pmid:8192083
    Abstract/FREE Full Text
  7. 7.↵
    1. Peyster RG,
    2. Augsburger JJ,
    3. Shields JA, et al
    . Intraocular tumors: evaluation with MR imaging. Radiology 1988;168:773–79 doi:10.1148/radiology.168.3.3406407 pmid:3406407
    CrossRefPubMed
  8. 8.↵
    1. Grech R,
    2. Cornish KS,
    3. Galvin PL, et al
    . Imaging of adult ocular and orbital pathology—a pictorial review. J Radiol Case Rep 2014;8:1–29 doi:10.3941/jrcr.v8i2.1525 pmid:24967016
    CrossRefPubMed
  9. 9.↵
    1. Modjtahedi BS,
    2. Rong A,
    3. Bobinski M, et al
    . Imaging characteristics of intraocular foreign bodies: a comparative study of plain film X-ray, computed tomography, ultrasound, and magnetic resonance imaging. Retina 2015;35:95–104 doi:10.1097/IAE.0000000000000271 pmid:25090044
    CrossRefPubMed
  10. 10.↵
    1. Malin DR,
    2. Aulino JM,
    3. Recchia FM
    . Intracranial hyperdense subarachnoid perfluorocarbon droplets after attempted retinal detachment treatment. Emerg Radiol 2007;14:261–63 doi:10.1007/s10140-007-0586-0 pmid:17318484
    CrossRefPubMed
  11. 11.↵
    1. Eller AW,
    2. Friberg TR,
    3. Mah F
    . Migration of silicone oil into the brain: a complication of intraocular silicone oil for retinal tamponade. Am J Ophthalmol 2000;129:685–88 doi:10.1016/s0002-9394(00)00368-8 pmid:10844074
    CrossRefPubMed
  • Received July 1, 2020.
  • Accepted after revision September 18, 2020.
  • © 2020 by American Journal of Neuroradiology
PreviousNext
Back to top
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MR Imaging Characteristics of Intraocular Perfluoro-n-Octane
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
M.T. Williams, J.E. Williams, B.A. Winegar, R.F. Carmody, J.B. Christoforidis
MR Imaging Characteristics of Intraocular Perfluoro-n-Octane
American Journal of Neuroradiology Dec 2020, DOI: 10.3174/ajnr.A6901

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
MR Imaging Characteristics of Intraocular Perfluoro-n-Octane
M.T. Williams, J.E. Williams, B.A. Winegar, R.F. Carmody, J.B. Christoforidis
American Journal of Neuroradiology Dec 2020, DOI: 10.3174/ajnr.A6901
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATION:
    • FINDINGS
    • DISCUSSION
    • CONCLUSIONS
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Chondrosarcoma vs Synovial Chondromatosis: Imaging
  • WHO Classification Update: Nasal&Skull Base Tumors
  • Peritumoral Signal in Vestibular Schwannomas
Show more HEAD & NECK

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire