Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticleInterventional

Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents

M.D. Joshi, C.J. O'Kelly, T. Krings, D. Fiorella and T.R. Marotta
American Journal of Neuroradiology August 2013, 34 (8) 1589-1592; DOI: https://doi.org/10.3174/ajnr.A3431
M.D. Joshi
aFrom the Department of Medical Imaging (M.D.J., T.K., T.R.M.), University of Toronto, Toronto, Ontario, Canada
bDivision of Neuroradiology (M.D.J., T.K.), Toronto Western Hospital, Toronto, Ontario, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.J. O'Kelly
cDivision of Neurosurgery (C.J.O.), Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Krings
aFrom the Department of Medical Imaging (M.D.J., T.K., T.R.M.), University of Toronto, Toronto, Ontario, Canada
bDivision of Neuroradiology (M.D.J., T.K.), Toronto Western Hospital, Toronto, Ontario, Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Fiorella
dDepartment of Neurological Surgery (D.F.), Stony Brook University Medical Centre, Stony Brook, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.R. Marotta
aFrom the Department of Medical Imaging (M.D.J., T.K., T.R.M.), University of Toronto, Toronto, Ontario, Canada
eDivision of Diagnostic and Therapeutic Neuroradiology (T.R.M.), St. Michael's Hospital, Toronto, Ontario, Canada.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Novel angiographic grading scales for the assessment of intracranial aneurysms treated with flow-diverting stents have been recently developed because previous angiographic grading scales cannot be applied to these aneurysms. The purpose of this study was to evaluate the inter- and intraobserver variability of the novel O'Kelly Marotta grading scale, which was developed specifically for the angiographic assessment of aneurysms treated with flow-diverting stents.

MATERIALS AND METHODS: Multiple raters (n = 31) from the disciplines of neuroradiology and neurosurgery were presented with pre- and posttreatment angiographic images of 14 aneurysms treated with intraluminal flow diverters. Raters were asked to classify pre- and posttreatment angiograms by using the OKM grading scale. Statistical analyses were subsequently performed with calculation of a generalized multirater κ statistic for assessment of inter- and intraobserver variability and by performing a Wilcoxon signed rank sum test for assessment of group differences.

RESULTS: Variability analysis of the OKM grading scale yielded substantial (κ = 0.74) and almost perfect (κ = 0.99) inter- and intraobserver agreement, respectively, with no statistically significant differences between raters with a background of neuroradiology versus neurosurgery or attending physician versus trainee.

CONCLUSIONS: The OKM grading scale for the assessment of intracranial aneurysms treated with flow-diverting stents is a reliable grading scale that can be used equally well by users of varying backgrounds and levels of training. Comparison with interobserver variability of pre-existing angiographic grading scales shows equal or better performance.

ABBREVIATIONS:

OKM
O'Kelly Marotta

The development of flow-diverting stents has ushered in an era of new paradigms and possibilities for the endovascular treatment of intracranial aneurysms. These devices are garnering momentum for difficult intracranial aneurysms that are wide-neck, have fusiform configuration, are located in perforator territories, or have complex geometry. Their mechanism of action relies on a reduction of filling of the aneurysmal sac with flow diversion toward the parent vessel, leading to stasis and subsequent thrombosis within the aneurysm. This process usually occurs with time, and angiographic evidence of aneurysm protection is usually not seen in immediate posttreatment angiograms. Rather, the process of stasis and thrombosis may not be complete for months after initial flow-diverting stent placement. While residual filling is a suboptimal or unacceptable posttreatment angiographic result for an aneurysm treated with endosacular coiling, this can be optimal and acceptable for an aneurysm treated by using flow-diverting devices. Traditional grading scales, such as the 3-point grading scale of Roy and Raymond used for aneurysms treated with coiling or clipping,1 do not apply to aneurysms treated with flow-diverting stents. For example, after treatment, filling within the aneurysm body would be classified as residual aneurysm and would not be considered a desirable result according to the Roy and Raymond classification, but in the case of flow-diverting stent placement, this would be an expected immediate posttreatment result.

A new grading scale specifically tailored to the angiographic assessment of aneurysms treated with flow-diverting stents was published by O'Kelly et al,2 termed the O'Kelly Marotta grading scale. This novel grading scale incorporates 2 dimensions as parameters, which reflect the mechanism by which flow-diverting devices accomplish aneurysm protection: reduction in aneurysm sac filling (filling grade), which reflects an anatomic aspect, and promotion of stasis within the aneurysm sac (stasis grade), which reflects a more dynamic or physiologic parameter (Fig 1).

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

OKM angiographic grading scale for assessment of aneurysms treated with flow-diverting stents. Aneurysms are assigned grades on the basis of the amount of contrast filling of the aneurysm lumen (filling grades, A, B, C, D) and how long contrast persists in the aneurysm lumen with respect to angiographic phase (stasis grades 1, 2, 3). A grade consisting of a letter and a number is assigned to an aneurysm (eg, an aneurysm that fills its lumen completely with contrast persisting within the lumen into the venous phase of the angiogram is assigned grade A3).2 Modified from O'Kelly CJ, Krings T, Fiorella D, et al. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 2010;16:133–37 and reproduced with permission from Centauro srl Publishing.

With any novel grading scale, an evaluation of performance in the hands of the evaluating end user is necessary for an assessment of reliability. We present here an analysis of the inter- and intraobserver variability of the OKM grading scale based on evaluation of conventional angiographic images of aneurysms pre- and posttreatment with flow-diverting stents by 31 evaluators with a background in neurointervention from the disciplines of neuroradiology and neurosurgery.

Materials and Methods

Fourteen cases of aneurysms, pre- and posttreatment with flow-diverting stents (28 conventional cerebral angiograms), were presented to 31 evaluators from the backgrounds of neuroradiology and neurosurgery. Angiograms were shown in the form of a high-resolution, scalable, multimedia-enabled, interactive document in Adobe Portable Document Format (Adobe Systems, San Jose, California). Two cases (4 angiograms) were duplicates placed randomly within the set for assessment of intraobserver variability. No patient-identifying, demographic, or flow-diversion device information was provided to any of the evaluators, and none of the evaluators had previous exposure or were involved in the treatment or follow-up of any of the cases presented. Evaluators were presented with a brief written introduction to the OKM grading scale and 2 case examples with answers. There was no personal coaching or verbal introduction given. Evaluators were asked to classify each of the angiograms of the aneurysms according to the OKM grading scale by selecting the appropriate filling grade and stasis grade from a drop-down menu.

Statistical analysis was performed by using statistical software (Statistical Package for the Social Sciences, Version 20; SPSS, Chicago, Illinois). A generalized nonweighted multirater κ statistic was calculated according to the method described by Siegal and Castellan.3 Categorization of κ values was based on Landis and Koch4 and reviewed in Fleiss et al.5 Differences between groups or raters were analyzed for statistical significance by using a Wilcoxon signed rank sum test.

Results

Thirty-one evaluators, predominantly neurointerventionalists, with backgrounds in neuroradiology (n = 24) and neurosurgery (n = 7) participated in the study. Evaluators were either fellows or attending physicians. Interobserver variability was assessed by using a generalized multirater κ statistic, which showed substantial agreement across all evaluators with κ = 0.74, a very low standard error, and a highly favorable P value (Table 1). Intraobserver variability, as determined by random insertion of 4 duplicate angiograms, was also excellent with κ = 0.99, indicating almost perfect agreement (Table 1).

View this table:
  • View inline
  • View popup
Table 1:

Individual and group variability for the OKM grading scale

To determine whether there were any differences in grading based on specialty background or level of training, we performed a Wilcoxon rank sum test. While the number of neuroradiologists participating in the study exceeded the number of neurosurgeons by greater than 3:1, no statistically significant difference existed between the responses provided by either group (Table 1). There was also no statistically significant difference in responses based on level of training (ie, fellow in training versus attending physician), again, with a greater number of attending physicians compared with fellows.

We were also interested in assessing the accuracy of responses with respect to each filling grade and stasis grade category. The percentage of correct responses is tabulated in Table 2. (The correct answer is based on consensus agreement in grading for a given angiogram based on evaluation by publication authors [M.D.J. and T.R.M.]) In general, accuracy was greater than 80% in all but one category, which was filling grade C, which corresponds to the category of entry remnant. According to the OKM grading scale, aneurysms that are pretreatment are graded as filling grade A, total filling, by definition (ie, >95%) even if they are partially thrombosed. This concept appears to have been well-grasped by raters, given the 93% accuracy achieved overall for pre- and posttreatment angiograms and 100% accuracy for grade A when pretreatment subgroup scores were tabulated. Accuracy for filling grades corresponding to 5%–95% aneurysm filling, grade B, and 0% aneurysm filling, grade D, showed 84% and 80% accuracy, respectively.

View this table:
  • View inline
  • View popup
Table 2:

Accuracy of rater response by grading category for the OKM grading scale

Evaluators were much less accurate in choosing filling grade C, or entry remnant category, which was reflected by an accuracy rate of 45%, which is substantially less than that in any of the other filling grade categories.

The accuracy of stasis grade scores (ie, grading the degree of contrast stasis within the aneurysm) ranged from 80% to 90%. Much of the variability in determining stasis grade was seen in cases in which filling of an overlapping venous plexus was mistaken for aneurysm filling or vice versa or where subtle stasis and a very small amount of filling persisted into the venous phase but was not detected by the evaluator.

Discussion

The mechanism by which flow-diverting stents divert flow from the aneurysm into the parent vessel leading to progressive stasis, thrombosis, and obliteration of the aneurysm has necessitated the development of new grading scales to assess treatment and predict effect. Widely used and validated scales for grading of coiled aneurysms such as the Roy and Raymond simplified scale6 do not apply to those treated with flow-diverting stents for which residual filling on the immediate posttreatment angiograms is acceptable and is the norm. Since the development of the OKM grading scale, the first published for aneurysms treated by using flow-diverting stents, other grading scales have also been developed. The grading scale by Kamran et al7 incorporates 2 main axes: axis I, assessing the degree of aneurysm occlusion, and axis II, assessing parent artery patency. This grading scale has favorable interobserver agreement for both axes (based on assessment by 2 expert raters) for anatomic parameters but does not address gradation of dynamic or physiologic parameters such as contrast stasis in the aneurysm lumen.

This study shows that the OKM grading scale has good inter- and intraobserver variability across many raters (n = 31) from varied backgrounds of neuroradiology and neurosurgery with different levels of experience. Our study does have some limitations in that the number of cases that each reader evaluated was limited to the grading of 28 angiograms. However, a high number of raters were recruited to more robustly address interobserver variability. Interobserver κ values may have been higher by selecting raters who were more experienced and coached on use of the grading scale; however, in reality, end-user populations normally comprise those without personal coaching as well as those with variable levels of expertise and the study was designed to capture this aspect. Personal coaching of raters may have also led to a higher degree of accuracy for the entry remnant category, defined as filling of <5%. Part of this is based on the difficulty of visually differentiating such a narrow range of aneurysm filling (ie, >0% to <5%) accurately. From a practical standpoint, the best angiographic view to assess and identify the entry remnant category is one in which the stent and the residual filling segment of the aneurysm are both in maximal profile. This view accomplishes visualization of what would be the aneurysm neck, by conventional nomenclature, and is where subtle residual contrast filling of the aneurysm of <5% would be best visualized.

The entry remnant would appear more like a sessile entity compared with one that is pedunculated or shows layering of contrast appearing like a fluid-fluid level or parfait. The entry remnant also has a propensity to occur in instances in which a small vessel arises from the aneurysm, functioning as a sump, keeping this small portion of the aneurysm persistently filling. However, with increasing and longer cumulative experience with flow-diversion devices, we are seeing that the entry remnant category could also be seen as a separate entity with its own prognostic significance and not only a continuum variable for filling grade. Some of our initial experiences suggest that aneurysms treated with flow-diversion stents that show angiographic appearances consistent with the entry remnant category have a propensity to fail to achieve complete exclusion from circulation. The details of the pathomechanism of this phenomenon are currently being explored (J.P. Cruz, personal communication, June 2011).

The interobserver variability of the OKM grading scale is comparable with well-established angiographic grading schemes for treated aneurysms (Table 3). Cloft et al8 evaluated various well-known aneurysm treatment grading schemes for observer variability with 2, 3, and 4 possibilities for grading based on the angiographic appearance, and reported κ values of 0.63, 0.54, and 0.50, respectively. Better agreement was observed in grading schemes with fewer assignment possibilities. In the OKM scale, there are 12 possibilities for grade assignment from 4 filling grades and 3 stasis grades, with an overall interobserver κ value of 0.74. Moreover, the OKM scale is also comparable with or better than, with respect to interobserver variability, other grading scales that also encompass >1 dimension of observation such as the Spetzler-Martin grading scale for AVM assessment, in which κ values of 0.479 and 0.7010 have been observed.

View this table:
  • View inline
  • View popup
Table 3:

Comparison of interobserver variability (κ) of the OKM grading scale and other angiographic grading scales

Conclusions

The OKM grading scale for assessment of intracranial aneurysms treated with flow-diverting stents demonstrates good inter- and intraobserver variability across a spectrum of raters of different backgrounds and experience. The scale shows comparable or better interobserver variability as judged by κ values compared with well-established angiographic grading scales. The OKM grading scale has not been formally validated in terms of its ability to predict treatment effect or aid in prognostic stratification; however, this will likely come to fruition as more collective long-term assessments for aneurysms treated with flow-diverting stents become available.

Acknowledgments

We thank all of the study participants for taking time out of their hectic schedules to participate in our study as well as Dr Hadas Moshonov, JDMI, statistician for discussions and advice regarding statistical analyses.

Footnotes

  • Disclosures: Cian O'Kelly—UNRELATED: Other: ev3 Endovascular, Comments: I have worked for ev3 as a proctor for Pipeline cases. David Fiorella—RELATED: Consulting Fee or Honorarium: Covidien/ev3, UNRELATED: Board Membership: Vascular Simulations, Computer Vision Systems Laboratories (CVSL), Consultancy: Codman/Johnson & Johnson, NFocus, WL Gore, Scientia, Grants/Grants Pending: National Institutes of Health (SAMMPRIS),* MicroVention (Low-profile Visualized Intraluminal Support Humanitarian Device Exemption Trial; preclinical device evaluation),* Siemens Healthcare, Patents (planned, pending, or issued): ReVasc Inc (acquired by Codman/Johnson and Johnson), Royalties: ReVasc Inc (acquired by Codman/Johnson & Johnson), Stock/Stock Options: Vascular Simulations, CVSL, Travel/Accommodations/Meeting Expenses Unrelated to Activities Listed: ev3/Covidien, Codman/Johnson & Johnson. Thomas R. Marotta—RELATED: Consulting Fee or Honorarium: for proctoring the Pipeline Embolization Device, UNRELATED: Patents (planned, pending, or issued): I have patents for the Endovascular Clip System (no money paid). *Money paid to the institution.

REFERENCES

  1. 1.↵
    1. Raymond J,
    2. Guilbert F,
    3. Weill A,
    4. et al
    . Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 2003;34:1398–403
    Abstract/FREE Full Text
  2. 2.↵
    1. O'Kelly CJ,
    2. Krings T,
    3. Fiorella D,
    4. et al
    . A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 2010;16:133–37
    Abstract/FREE Full Text
  3. 3.↵
    1. Siegal S,
    2. Castellan NJ
    . Nonparametric Statistics for the Behavioral Sciences. 2nd ed. New York: McGraw-Hill; 1988
  4. 4.↵
    1. Landis JR,
    2. Koch GG
    . The measurement of observer agreement for categorical data. Biometrics 1977;33:159–74
    CrossRefPubMed
  5. 5.↵
    1. Fleiss JL,
    2. Levin BA,
    3. Paik MC
    . Statistical Methods for Rates and Proportions. 3rd ed. Hoboken, New Jersey: J Wiley; 2003
  6. 6.↵
    1. Roy D,
    2. Milot G,
    3. Raymond J
    . Endovascular treatment of unruptured aneurysms. Stroke 2001;32:1998–2004
    Abstract/FREE Full Text
  7. 7.↵
    1. Kamran M,
    2. Yarnold J,
    3. Grunwald IQ,
    4. et al
    . Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schema. Neuroradiology 2011;53:501–08
    CrossRefPubMed
  8. 8.↵
    1. Cloft HJ,
    2. Kaufmann T,
    3. Kallmes DF
    . Observer agreement in the assessment of endovascular aneurysm therapy and aneurysm recurrence. AJNR Am J Neuroradiol 2007;28:497–500
    Abstract/FREE Full Text
  9. 9.↵
    1. Al-Shahi R,
    2. Pal N,
    3. Lewis SC,
    4. et al
    . Observer agreement in the angiographic assessment of arteriovenous malformations of the brain. Stroke 2002;33:1501–08
    Abstract/FREE Full Text
  10. 10.↵
    1. Iancu-Gontard D,
    2. Weill A,
    3. Guilbert F,
    4. et al
    . Inter- and intraobserver variability in the assessment of brain arteriovenous malformation angioarchitecture and endovascular treatment results. AJNR Am J Neuroradiol 2007;28:524–27
    Abstract/FREE Full Text
  • Received June 6, 2012.
  • Accepted after revision October 5, 2012.
  • © 2013 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 34 (8)
American Journal of Neuroradiology
Vol. 34, Issue 8
1 Aug 2013
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
M.D. Joshi, C.J. O'Kelly, T. Krings, D. Fiorella, T.R. Marotta
Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
American Journal of Neuroradiology Aug 2013, 34 (8) 1589-1592; DOI: 10.3174/ajnr.A3431

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
M.D. Joshi, C.J. O'Kelly, T. Krings, D. Fiorella, T.R. Marotta
American Journal of Neuroradiology Aug 2013, 34 (8) 1589-1592; DOI: 10.3174/ajnr.A3431
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Comparison of a covered stent and pipeline embolization device in intracranial aneurysm: a propensity score matching analysis
  • Comparison of the Pipeline embolisation device alone or combined with coiling for treatment of different sizes of intracranial aneurysms
  • Efficacy and safety of the dual-layer flow-diverting stent (FRED) for the treatment of intracranial aneurysms
  • Treatment of Intra- and Extracranial Aneurysms Using the Flow-Redirection Endoluminal Device: Multicenter Experience and Follow-Up Results
  • Inter-rater reliability of published flow diversion occlusion scales
  • Crossref (26)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Hemodynamics of Flow Diverters
    Ronak Dholakia, Chander Sadasivan, David J. Fiorella, Henry H. Woo, Baruch B. Lieber
    Journal of Biomechanical Engineering 2017 139 2
  • Treatment of Intra- and Extracranial Aneurysms Using the Flow-Redirection Endoluminal Device: Multicenter Experience and Follow-Up Results
    F. Drescher, W. Weber, A. Berlis, S. Rohde, A. Carolus, S. Fischer
    American Journal of Neuroradiology 2017 38 1
  • Efficacy and safety of the dual-layer flow-diverting stent (FRED) for the treatment of intracranial aneurysms
    Leopoldo Guimaraens, Elio Vivas, Jesus Saldaña, Juan Carlos Llibre, Alberto Gil, Ernest Balaguer, Ana Rodríguez-Campello, Elisa Cuadrado-Godia, Angel Ois
    Journal of NeuroInterventional Surgery 2020 12 5
  • Flow Diversion for Reconstruction of Intradural Vertebral Artery Dissecting Aneurysms Causing Subarachnoid Hemorrhage—A Retrospective Study From Four Neurovascular Centers
    Jens Maybaum, Hans Henkes, Marta Aguilar-Pérez, Victoria Hellstern, Georg Alexander Gihr, Wolfgang Härtig, André Reisberg, Dirk Mucha, Marie-Sophie Schüngel, Richard Brill, Ulf Quäschling, Karl-Titus Hoffmann, Stefan Schob
    Frontiers in Neurology 2021 12
  • Comparison of the Pipeline embolisation device alone or combined with coiling for treatment of different sizes of intracranial aneurysms
    Chao Wang, Bin Luo, Tianxiao Li, Aisha Maimaitili, Guohua Mao, Donglei Song, Yunyan Wang, Wenfeng Feng, Yang Wang, Huaizhang Shi, Jieqing Wan, Jianmin Liu, Sheng Guan, Yuanli Zhao, Hongqi Zhang
    Stroke and Vascular Neurology 2022 7 4
  • Flow Diverter in Unruptured Intracranial Vertebral Artery Dissecting Aneurysm
    Han San Oh, Jin Woo Bae, Chang-eui Hong, Kang Min Kim, Dong Hyun Yoo, Hyun-Seung Kang, Young Dae Cho
    Frontiers in Neurology 2022 13
  • Treatment of Intracranial Aneurysms with Flow Re-direction Endoluminal Device - A Single Centre Experience with Short-term Follow-up Results
    Neeraj Ramesh Mahboobani, Wing Ho Chong, Samuel Siu Kei Lam, Jimmy Chi Wai Siu, Chong Boon Tan, Yiu Chung Wong
    Neurointervention 2017 12 1
  • Flow diversion for aneurysms beyond the circle of Willis: A preliminary experience
    Sisi Li, Zhiwen Lu, Haishuang Tang, Chenghao Shang, Rui Zhao, Dongwei Dai, Qiang Li, Bo Hong, Qinghai Huang, Yu Zhou, Jianmin Liu
    Journal of Clinical Neuroscience 2022 95
  • Flow diversion treatment of anterior communicating artery region aneurysms
    Krishna Amuluru, Fawaz Al-Mufti, Charles Edward Romero
    Journal of Neuroradiology 2021 48 5
  • Inter-rater reliability of published flow diversion occlusion scales
    Marcus D Mazur, Philipp Taussky, Lubdha M Shah, Blair Winegar, Min S Park
    Journal of NeuroInterventional Surgery 2016 8 12

More in this TOC Section

  • SAVE vs. Solumbra Techniques for Thrombectomy
  • Contrast-Induced Encephalopathy after NeuroIR
  • CT Perfusion&Reperfusion in Acute Ischemic Stroke
Show more Interventional

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire