Research ArticleINTERVENTIONAL
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm: Evaluation of Potential Treatment Regimens
Steven G. Imbesi and Charles W. Kerber
American Journal of Neuroradiology April 2001, 22 (4) 721-724;

References
- ↵Kerber CW, Heilman CB. Flow dynamics in the human carotid artery. AJNR Am J Neuroradiol 1992;13:173-180
- Burleson AC, Strother CM, Turitto VT. Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. Neurosurgery 1995;37:774-782
- ↵Imbesi SG, Kerber CW. Analysis of slipstream flow in two ruptured intracranial cerebral aneurysms. AJNR Am J Neuroradiol 1999;20:1703-1705
- ↵Kerber CW, Heilman CB, Zanetti PH. Transparent elastic arterial models, I: a brief technical note. Biorheology 1989;26:1041-1049
- ↵Mann DE, Tarbell JM. Flow of non-Newtonian blood analog fluids in rigid curved and straight artery models. Biorheology 1990;27:711-733
- ↵Keller HM, Merer WE, Anliker M, et al. Non-invasive measurement of velocity profiles and blood flow in the common carotid artery by pulsed Doppler ultrasound. Stroke 1976;7:370-377
- ↵Giglielmi G, Vinuela F, Briganti F, Duckwiler G. Carotid-cavernous fistula caused by a ruptured intracavernous aneurysm: endovascular treatment by electrothrombosis with detachable coils. Neurosurgery 1992;31:591-597
- ↵Moret J, Cognard C, Weil A, Castaings L, Rey A. Reconstruction technic in the treatment of wide-necked intracranial aneurysms: long-term angiographic and clinical results: apropos of 56 cases. J Neuroradiol 1997;24:30-44
- ↵Wilms G, van Calenbergh F, Stockx L, Demaerel P, van Loon J, Goffin J. Endovascular treatment of a ruptured paraclinoid aneurysm of the carotid siphon achieved using endovascular stent and endosaccular coil placement. AJNR Am J Neuroradiol 2000;21:753-756
- Sekhon LHS, Morgan MK, Sorby W, Grinnell V. Combined endovascular stent implantation and endosaccular coil placement for the treatment of a wide-necked vertebral artery aneurysm: technical case report. Neurosurgery 1998;43:385-388
- ↵Aenis M, Stancampiano AP, Wakhloo AK, Lieber BB. Modeling of flow in a straight stented and non-stented side wall aneurysm model. J Biomech Eng 1997;119:206-212
- Lanzino G, Wakhloo AK, Fessler RD, Hartney ML, Guterman LR, Hopkins LN. Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms. J Neurosurg 1999;91:539-547
In this issue
Advertisement
Steven G. Imbesi, Charles W. Kerber
Analysis of Slipstream Flow in a Wide-necked Basilar Artery Aneurysm: Evaluation of Potential Treatment Regimens
American Journal of Neuroradiology Apr 2001, 22 (4) 721-724;
0 Responses
Jump to section
Related Articles
- No related articles found.
Cited By...
- Identification of the Inflow Zone of Unruptured Cerebral Aneurysms: Comparison of 4D Flow MRI and 3D TOF MRA Data
- Using Leo Plus stent as flow diverter and endoluminal remodeling in endovascular treatment of intracranial fusiform aneurysms
- In Vitro Study of Near-Wall Flow in a Cerebral Aneurysm Model with and without Coils
- Image-Based Computational Simulation of Flow Dynamics in a Giant Intracranial Aneurysm
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement