Research ArticleBRAIN
MR Imaging-Related Heating of Deep Brain Stimulation Electrodes: In Vitro Study
Daniel A. Finelli, Ali R. Rezai, Paul M. Ruggieri, Jean A. Tkach, John A. Nyenhuis, Greg Hrdlicka, Ashwini Sharan, Jorge Gonzalez-Martinez, Paul H. Stypulkowski and Frank G. Shellock
American Journal of Neuroradiology November 2002, 23 (10) 1795-1802;
Daniel A. Finelli
Ali R. Rezai
Paul M. Ruggieri
Jean A. Tkach
John A. Nyenhuis
Greg Hrdlicka
Ashwini Sharan
Jorge Gonzalez-Martinez
Paul H. Stypulkowski

Submit a Response to This Article
Jump to comment:
No eLetters have been published for this article.
In this issue
Advertisement
Daniel A. Finelli, Ali R. Rezai, Paul M. Ruggieri, Jean A. Tkach, John A. Nyenhuis, Greg Hrdlicka, Ashwini Sharan, Jorge Gonzalez-Martinez, Paul H. Stypulkowski, Frank G. Shellock
MR Imaging-Related Heating of Deep Brain Stimulation Electrodes: In Vitro Study
American Journal of Neuroradiology Nov 2002, 23 (10) 1795-1802;
MR Imaging-Related Heating of Deep Brain Stimulation Electrodes: In Vitro Study
Daniel A. Finelli, Ali R. Rezai, Paul M. Ruggieri, Jean A. Tkach, John A. Nyenhuis, Greg Hrdlicka, Ashwini Sharan, Jorge Gonzalez-Martinez, Paul H. Stypulkowski, Frank G. Shellock
American Journal of Neuroradiology Nov 2002, 23 (10) 1795-1802;
Jump to section
Related Articles
- No related articles found.
Cited By...
- Brain-implanted conductors amplify radiofrequency fields in rodents: advantages and risks
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants
- Low-Power Inversion Recovery MRI Preserves Brain Tissue Contrast for Patients with Parkinson Disease with Deep Brain Stimulators
- Safety of retained microcatheters: an evaluation of radiofrequency heating in endovascular microcatheters with nitinol, tungsten, and polyetheretherketone braiding at 1.5 T and 3 T
- Mapping and Ablation of the Pulmonary Veins and Cavo-Tricuspid Isthmus With a Magnetic Resonance Imaging-Compatible Externally Irrigated Ablation Catheter and Integrated Electrophysiology System
- Modern Pacemaker and Implantable Cardioverter/Defibrillator Systems Can Be Magnetic Resonance Imaging Safe: In Vitro and In Vivo Assessment of Safety and Function at 1.5 T
- Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement