Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Other Publications
    • ajnr

User menu

  • Subscribe
  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

  • Subscribe
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Publication Preview--Ahead of Print
    • Past Issue Archive
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
    • COVID-19 Content and Resources
  • For Authors
  • About Us
    • About AJNR
    • Editors
    • American Society of Neuroradiology
  • Submit a Manuscript
  • Podcasts
    • Subscribe on iTunes
    • Subscribe on Stitcher
  • More
    • Subscribers
    • Permissions
    • Advertisers
    • Alerts
    • Feedback
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds
Letter

Increasing the Accuracy of Optic Nerve Measurement Using 3D Volumetry

A. Lecler, J. Savatovsky and C. Lamirel
American Journal of Neuroradiology June 2018, 39 (6) E80; DOI: https://doi.org/10.3174/ajnr.A5625
A. Lecler
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Lecler
J. Savatovsky
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J. Savatovsky
C. Lamirel
bDepartment of Ophthalmology Fondation Ophtalmologique Adolphe de Rothschild Paris, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C. Lamirel
  • Article
  • Info & Metrics
  • References
  • PDF
Loading

We read with much interest the article by Hoffmann et al in the February 2018 issue of the American Journal of Neuroradiology regarding the measurement of the optic nerve using MR imaging on pediatric patients. The authors provided values for optic nerve sizes correlated with the ages of enrolled children.

However, despite stating in their introduction that the use of new volumetric methods with thin-cut images could help obtain accurate measurements, they provided only 2D measurements of the optic nerve using 2D sequences, which are less accurate and reproducible than volumetric data.1 Volumetry is dependent on neither orbital morphology nor volume nor on the disposition and course of the optic nerve. Optic nerves are flexible structures with a unique orbital fixed anchor point at the apex. Thus, they easily stretch or become lax in their orbital portion, especially in the case of orbital diseases such as optic neuropathy or optic nerve tumors. Intraorbital portion length varies among individuals. Optic nerves may have a tortuous or stretched path in the case of intracranial hyper- or hypotension, respectively. Therefore, 2D measurements obtained from 2 fixed distances at 3 and 7 mm posterior to the lamina cribrosa in the axial plane as performed in this article vary so much among individuals that the authors' conclusions could be questioned.

Moreover, the measurements of the optic nerve in the coronal plane are inaccurate due to the oblique course of the nerve. The use of coronal acquisitions orthogonal to the nerve is mandatory to provide accurate measurements. Thus, coronal diameters are probably overestimated in this article. Some authors suggest measuring the mean cross-sectional area of the intraorbital portion of each optic nerve,2 but volumetric measurements are better and more accurate.3

The use of STIR sequences is also questionable because this sequence has the disadvantage of producing a high signal from CSF, obscuring the edge of the optic nerve and, consequently, blocking a clear image of the optic nerve sheath. The optic nerves were reported to be about 20% greater than with a FLAIR sequence.2

Thus, the measurements of the optic nerve provided in this article should be used with caution.

To correct these weaknesses and provide the most accurate measurements of the optic nerve, we advise developing a prospective study with the same MR imaging acquisitions on the same MR imaging device for all patients, preferably using high-field MR imaging (3T or more), including 3D high-spatial-resolution sequences with inframillimetric slices without gaps. Fat- and CSF-saturated sequences with high signal and contrast-to-noise ratio should be used. Acquisition time should remain short to avoid kinetic artifacts. Patients should be advised to look at a fixed point in the MR imaging to avoid eye movement, which may modify the course of the optic nerve.

Automatic or semiautomatic volumetry can be easily performed on many posttreatment software packages. In a routine radiologic setting, image postprocessing with quantitative analysis can be achieved rapidly (10 minutes) by experienced radiologists.1,3 Volumetry has been widely validated in neurologic and orbital studies and is reproducible.1,4

Finally, we agree with the authors that there is a need to establish a standardized method for the measurement of the optic nerve on MR imaging, but we believe that volumetric measurements should be made including the entire volume of the optic nerve starting from the papilla and ending at the point of convergence of the extraocular muscles at the tendinous ring of the orbital apex,1 or ending at the chiasma, to provide accurate and reproducible measurements.

REFERENCES

  1. 1.↵
    1. Hoffmann J,
    2. Schmidt C,
    3. Kunte H, et al
    . Volumetric assessment of optic nerve sheath and hypophysis in idiopathic intracranial hypertension. AJNR Am J Neuroradiol 2014;35:513–18 doi:10.3174/ajnr.A3694 pmid:24029390
    Abstract/FREE Full Text
  2. 2.↵
    1. Hickman SJ,
    2. Brex PA,
    3. Brierley CM, et al
    . Detection of optic nerve atrophy following a single episode of unilateral optic neuritis by MRI using a fat-saturated short-echo fast FLAIR sequence. Neuroradiology 2001;43:123–28 doi:10.1007/s002340000450 pmid:11326556
    CrossRefPubMed
  3. 3.↵
    1. Agid R,
    2. Farb RI,
    3. Willinsky RA, et al
    . Idiopathic intracranial hypertension: the validity of cross-sectional neuroimaging signs. Neuroradiology 2006;48:521–27 doi:10.1007/s00234-006-0095-y pmid:16703359
    CrossRefPubMed
  4. 4.↵
    1. Maresky HS,
    2. Ben Ely A,
    3. Bartischovsky T, et al
    . MRI measurements of the normal pediatric optic nerve pathway. J Clin Neurosci 2018;48:209–13 doi:10.1016/j.jocn.2017.11.015 pmid:29198418
    CrossRefPubMed
  • © 2018 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 39 (6)
American Journal of Neuroradiology
Vol. 39, Issue 6
1 Jun 2018
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Increasing the Accuracy of Optic Nerve Measurement Using 3D Volumetry
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Increasing the Accuracy of Optic Nerve Measurement Using 3D Volumetry
A. Lecler, J. Savatovsky, C. Lamirel
American Journal of Neuroradiology Jun 2018, 39 (6) E80; DOI: 10.3174/ajnr.A5625

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Increasing the Accuracy of Optic Nerve Measurement Using 3D Volumetry
A. Lecler, J. Savatovsky, C. Lamirel
American Journal of Neuroradiology Jun 2018, 39 (6) E80; DOI: 10.3174/ajnr.A5625
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • References
  • PDF

Related Articles

  • REPLY:
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref (1)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Stratégies diagnostiques devant une baisse d’acuité visuelle
    A. Lecler, O. Bergès, F. Héran, L. Duron, J. Savatovsky
    Journal d'imagerie diagnostique et interventionnelle 2020 3 4

Similar Articles

Advertisement

News and Updates

  • Lucien Levy Best Research Article Award
  • Thanks to our 2022 Distinguished Reviewers
  • Press Releases

Resources

  • Evidence-Based Medicine Level Guide
  • How to Participate in a Tweet Chat
  • AJNR Podcast Archive
  • Ideas for Publicizing Your Research
  • Librarian Resources
  • Terms and Conditions

Opportunities

  • Share Your Art in Perspectives
  • Get Peer Review Credit from Publons
  • Moderate a Tweet Chat

American Society of Neuroradiology

  • Neurographics
  • ASNR Annual Meeting
  • Fellowship Portal
  • Position Statements

© 2023 by the American Society of Neuroradiology | Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire