Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticleSpine

Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas

A.A. Madhavan, L. Yu, W. Brinjikji, J.K. Cutsforth-Gregory, F.R. Schwartz, I.T. Mark, J.C. Benson and T.J. Amrhein
American Journal of Neuroradiology June 2023, 44 (6) 740-744; DOI: https://doi.org/10.3174/ajnr.A7887
A.A. Madhavan
aFrom the Division of Neuroradiology (A.A.M., L.Y., W.B., I.T.M., J.C.B.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A.A. Madhavan
L. Yu
aFrom the Division of Neuroradiology (A.A.M., L.Y., W.B., I.T.M., J.C.B.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W. Brinjikji
aFrom the Division of Neuroradiology (A.A.M., L.Y., W.B., I.T.M., J.C.B.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for W. Brinjikji
J.K. Cutsforth-Gregory
bDepartment of Radiology and Department of Neurology (J.K.C.-G.), Mayo Clinic, Rochester, Minnesota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.K. Cutsforth-Gregory
F.R. Schwartz
cDivision of Neuroradiology (F.R.S., T.J.A.), Department of Radiology, Duke University Medical Center, Durham, North Carolina
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for F.R. Schwartz
I.T. Mark
aFrom the Division of Neuroradiology (A.A.M., L.Y., W.B., I.T.M., J.C.B.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for I.T. Mark
J.C. Benson
aFrom the Division of Neuroradiology (A.A.M., L.Y., W.B., I.T.M., J.C.B.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.C. Benson
T.J. Amrhein
cDivision of Neuroradiology (F.R.S., T.J.A.), Department of Radiology, Duke University Medical Center, Durham, North Carolina
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for T.J. Amrhein
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

References

  1. 1.↵
    1. Schievink WI,
    2. Maya MM,
    3. Jean-Pierre S, et al
    . A classification system of spontaneous spinal CSF leaks. Neurology 2016;87:673–79 doi:10.1212/WNL.0000000000002986 pmid:27440149
    Abstract/FREE Full Text
  2. 2.↵
    1. Kranz PG,
    2. Gray L,
    3. Amrhein TJ
    . Decubitus CT myelography for detecting subtle CSF leaks in spontaneous intracranial hypotension. AJNR Am J Neuroradiol 2019;40:754–56 doi:10.3174/ajnr.A5995 pmid:30819772
    Abstract/FREE Full Text
  3. 3.↵
    1. Mamlouk MD,
    2. Ochi RP,
    3. Jun P, et al
    . Decubitus CT myelography for CSF-venous fistulas: a procedural approach. AJNR Am J Neuroradiol 2021;42:32–36 doi:10.3174/ajnr.A6844 pmid:33122215
    Abstract/FREE Full Text
  4. 4.↵
    1. Mark IT,
    2. Amans MR,
    3. Shah VN, et al
    . Resisted inspiration: a new technique to aid in the detection of CSF-venous fistulas. AJNR Am J Neuroradiol 2022;43:1544–47 doi:10.3174/ajnr.A7636 pmid:36137659
    Abstract/FREE Full Text
  5. 5.↵
    1. Amrhein TJ,
    2. Gray L,
    3. Malinzak MD, et al
    . Respiratory phase affects the conspicuity of CSF-venous fistulas in spontaneous intracranial hypotension. AJNR Am J Neuroradiol 2020;41:1754–56 doi:10.3174/ajnr.A6663 pmid:32675336
    Abstract/FREE Full Text
  6. 6.↵
    1. Madhavan AA,
    2. Cutsforth-Gregory JK,
    3. Benson JC, et al
    . Conebeam CT as an adjunct to digital subtraction myelography for detection of CSF-venous fistulas. AJNR Am J Neuroradiol 2023;44:347–50 doi:10.3174/ajnr.A7794 pmid:36759140
    Abstract/FREE Full Text
  7. 7.↵
    1. Leng S,
    2. Bruesewitz M,
    3. Tao S, et al
    . Photon-counting detector CT: system design and clinical applications of an emerging technology. Radiographics 2019;39:729–43 doi:10.1148/rg.2019180115 pmid:31059394
    CrossRefPubMed
  8. 8.↵
    1. Rajendran K,
    2. Petersilka M,
    3. Henning A, et al
    . First clinical photon-counting detector CT system: technical evaluation. Radiology 2022;303:130–38 doi:10.1148/radiol.212579 pmid:34904876
    CrossRefPubMed
  9. 9.↵
    1. Schwartz FR,
    2. Malinzak MD,
    3. Amrhein TJ
    . Photon-counting computed tomography scan of a cerebrospinal fluid venous fistula. JAMA Neurol 2022;79:628–29 doi:10.1001/jamaneurol.2022.0687 pmid:35435944
    CrossRefPubMed
  10. 10.↵
    1. Kim DK,
    2. Brinjikji W,
    3. Morris PP, et al
    . Lateral decubitus digital subtraction myelography: tips, tricks, and pitfalls. AJNR Am J Neuroradiol 2020;41:21–28 doi:10.3174/ajnr.A6368 pmid:31857327
    Abstract/FREE Full Text
  11. 11.↵
    1. Carlton Jones L,
    2. Goadsby PJ
    . Same-day bilateral decubitus CT myelography for detecting CSF-venous fistulas in spontaneous intracranial hypotension. AJNR Am J Neuroradiol 2022;43:645–48 doi:10.3174/ajnr.A7476 pmid:35332017
    Abstract/FREE Full Text
  12. 12.↵
    1. Kranz PG,
    2. Gray L,
    3. Malinzak MD, et al
    . CSF-venous fistulas: anatomy and diagnostic imaging. AJR Am J Roentgenol 2021;217:1418–29 doi:10.2214/AJR.21.26182 pmid:34191547
    CrossRefPubMed
  13. 13.↵
    1. Albrecht MH,
    2. Vogl TJ,
    3. Martin SS, et al
    . Review of clinical applications for virtual monoenergetic dual-energy CT. Radiology 2019;293:260–71 doi:10.1148/radiol.2019182297 pmid:31502938
    CrossRefPubMed
  14. 14.↵
    1. Mark I,
    2. Madhavan A,
    3. Oien M, et al
    . Temporal characteristics of CSF-venous fistulas on digital subtraction myelography. AJNR Am J Neuroradiol 2023;44:492–95 doi:10.3174/ajnr.A7809 pmid:36894299
    Abstract/FREE Full Text
  15. 15.↵
    1. Mamlouk MD,
    2. Shen PY,
    3. Dahlin BC
    . Modified dynamic CT myelography for type 1 and 2 CSF leaks: a procedural approach. AJNR Am J Neuroradiol 2023;44:341–46 doi:10.3174/ajnr.A7784 pmid:36732032
    Abstract/FREE Full Text
  16. 16.↵
    1. Nicholson PJ,
    2. Guest WC,
    3. van Prooijen M, et al
    . Digital subtraction myelography is associated with less radiation dose than CT-based techniques. Clin Neuroradiol 2021;31:627–31 doi:10.1007/s00062-020-00942-x pmid:32804244
    CrossRefPubMed
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 44 (6)
American Journal of Neuroradiology
Vol. 44, Issue 6
1 Jun 2023
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
A.A. Madhavan, L. Yu, W. Brinjikji, J.K. Cutsforth-Gregory, F.R. Schwartz, I.T. Mark, J.C. Benson, T.J. Amrhein
Utility of Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas
American Journal of Neuroradiology Jun 2023, 44 (6) 740-744; DOI: 10.3174/ajnr.A7887

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Photon-Counting CT Myelography for CSF-Fistulas
A.A. Madhavan, L. Yu, W. Brinjikji, J.K. Cutsforth-Gregory, F.R. Schwartz, I.T. Mark, J.C. Benson, T.J. Amrhein
American Journal of Neuroradiology Jun 2023, 44 (6) 740-744; DOI: 10.3174/ajnr.A7887
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • Acknowledgment
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Additional Diagnostic Value of Conebeam CT Myelography Performed after Digital Subtraction Myelography for Detecting CSF-Venous Fistulas
  • Photon-Counting CT Myelography for the Detection of Spinal CSF Leaks
  • CSF-Venous Fistulas Arising Intraosseously within Bone Remodeled by Meningeal Diverticula
  • Spontaneous Intracranial Hypotension in Children: A Multi-Institutional Review of Spinal CSF Leaks Localized on Advanced Myelography
  • Spinal CSF Leaks: The Neuroradiologist Transforming Care
  • Myelographic Techniques for the Localization of CSF-Venous Fistulas: Updates in 2024
  • Direct comparison of digital subtraction myelography versus CT myelography in lateral decubitus position: evaluation of diagnostic yield for cerebrospinal fluid-venous fistulas
  • Diagnostic Yield of Decubitus CT Myelography for Detection of CSF-Venous Fistulas
  • Photon-Counting CT in the Head and Neck: Current Applications and Future Prospects
  • Back to the Future: Dynamic Contrast-Enhanced Photon-Counting Detector CT for the Detection of Pituitary Adenoma in Cushing Disease
  • Benefits of Photon-Counting CT Myelography for Localization of Dural Tears in Spontaneous Intracranial Hypotension
  • Application of a Denoising High-Resolution Deep Convolutional Neural Network to Improve Conspicuity of CSF-Venous Fistulas on Photon-Counting CT Myelography
  • Diagnostic Performance of Decubitus Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas
  • Crossref (27)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Diagnostic Performance of Decubitus Photon-Counting Detector CT Myelography for the Detection of CSF-Venous Fistulas
    Ajay A. Madhavan, Jeremy K. Cutsforth-Gregory, Waleed Brinjikji, Girish Bathla, John C. Benson, Felix E. Diehn, Laurence J. Eckel, Ian T. Mark, Pearse P. Morris, Melissa A. Payne, Jared T. Verdoorn, Nikkole M. Weber, Lifeng Yu, Francis Baffour, Joel G. Fletcher, Cynthia H. McCollough
    American Journal of Neuroradiology 2023 44 12
  • Direct comparison of digital subtraction myelography versus CT myelography in lateral decubitus position: evaluation of diagnostic yield for cerebrospinal fluid-venous fistulas
    Niklas Lützen, Theo Demerath, Urs Würtemberger, Nebiyat Filate Belachew, Enrique Barvulsky Aleman, Katharina Wolf, Amir El Rahal, Florian Volz, Christian Fung, Jürgen Beck, Horst Urbach
    Journal of NeuroInterventional Surgery 2024 16 10
  • Myelography Using Energy-Integrating Detector CT Versus Photon-Counting Detector CT for Detection of CSF-Venous Fistulas in Patients With Spontaneous Intracranial Hypotension
    Fides R. Schwartz, Peter G. Kranz, Michael D. Malinzak, David N. Cox, Francesco Ria, Cindy McCabe, Brian Harrawood, Linda G. Leithe, Ehsan Samei, Timothy J. Amrhein
    American Journal of Roentgenology 2024 222 4
  • Diagnostic Yield of Decubitus CT Myelography for Detection of CSF-Venous Fistulas
    Jacob T. Gibby, Timothy J. Amrhein, Derek S. Young, Jessica L. Houk, Peter G. Kranz
    American Journal of Neuroradiology 2024 45 10
  • Myelographic Techniques for the Localization of CSF-Venous Fistulas: Updates in 2024
    Ajay A. Madhavan, Waleed Brinjikji, Jeremy K. Cutsforth-Gregory, Timothy J. Amrhein, Peter G. Kranz, John C. Benson, Felix E. Diehn, Ben A. Johnson-Tesch, Greta B. Liebo, Vance T. Lehman, Ian T. Mark, Pearse P. Morris, Michael P. Oien, Darya P. Shlapak, Jared T. Verdoorn
    American Journal of Neuroradiology 2024 45 10
  • Photon counting CT clinical adoption, integration, and workflow
    Bari Dane, Adam Froemming, Fides R. Schwartz, Aran Toshav, Juan Carlos Ramirez-Giraldo, Lakshmi Ananthakrishnan
    Abdominal Radiology 2024 49 12
  • Application of a Denoising High-Resolution Deep Convolutional Neural Network to Improve Conspicuity of CSF-Venous Fistulas on Photon-Counting CT Myelography
    Ajay A. Madhavan, Jeremy K. Cutsforth-Gregory, Waleed Brinjikji, John C. Benson, Felix E. Diehn, Ian T. Mark, Jared T. Verdoorn, Zhongxing Zhou, Lifeng Yu
    American Journal of Neuroradiology 2024 45 1
  • Photon-Counting CT in the Head and Neck: Current Applications and Future Prospects
    John C. Benson, Norbert G. Campeau, Felix E. Diehn, John I. Lane, Shuai Leng, Gul Moonis
    American Journal of Neuroradiology 2024 45 8
  • Benefits of Photon-Counting CT Myelography for Localization of Dural Tears in Spontaneous Intracranial Hypotension
    Ajay A. Madhavan, Jeremy K. Cutsforth-Gregory, Waleed Brinjikji, John C. Benson, Ben A. Johnson-Tesch, Greta B. Liebo, Ian T. Mark, Michael P. Oien, Darya P. Shlapak, Lifeng Yu, Jared T. Verdoorn
    American Journal of Neuroradiology 2024 45 5
  • High yield clinical applications for photon counting CT in neurovascular imaging
    Ajay A Madhavan, Girish Bathla, John C Benson, Felix E Diehn, Alex A Nagelschneider, Vance T Lehman
    British Journal of Radiology 2024 97 1157

More in this TOC Section

  • Bern Score Validity for SIH
  • MP2RAGE 7T in MS Lesions of the Cervical Spine
  • Deep Learning for STIR Spine MRI Quality
Show more Spine

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire