Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticleAdult Brain

Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions

J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer and O. Rapalino
American Journal of Neuroradiology September 2017, 38 (9) 1689-1694; DOI: https://doi.org/10.3174/ajnr.A5293
J. Fagundes
aFrom the Clínica de Diagnóstico por Imagem (J.F.), Rio de Janeiro, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J. Fagundes
M.G. Longo
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M.G. Longo
S.Y. Huang
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.Y. Huang
B.R. Rosen
cAthinoula A. Martinos Center for Biomedical Imaging (B.R.R., T.W.), Charlestown, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for B.R. Rosen
T. Witzel
cAthinoula A. Martinos Center for Biomedical Imaging (B.R.R., T.W.), Charlestown, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for T. Witzel
K. Heberlein
dSiemens Medical Solutions (K.H.), Malvern, Pennsylvania.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for K. Heberlein
R.G. Gonzalez
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.G. Gonzalez
P. Schaefer
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. Schaefer
O. Rapalino
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for O. Rapalino
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: The development of new MR imaging scanners with stronger gradients and improvement in coil technology, allied with emerging fast imaging techniques, has allowed a substantial reduction in MR imaging scan times. Our goal was to develop a 10-minute gadolinium-enhanced brain MR imaging protocol with accelerated sequences and to evaluate its diagnostic performance compared with the standard clinical protocol.

MATERIALS AND METHODS: Fifty-three patients referred for brain MR imaging with contrast were scanned with a 3T scanner. Each MR image consisted of 5 basic fast precontrast sequences plus standard and accelerated versions of the same postcontrast T1WI sequences. Two neuroradiologists assessed the image quality and the final diagnosis for each set of postcontrast sequences and compared their performances.

RESULTS: The acquisition time of the combined accelerated pre- and postcontrast sequences was 10 minutes and 15 seconds; and of the fast postcontrast sequences, 3 minutes and 36 seconds, 46% of the standard sequences. The 10-minute postcontrast axial T1WI had fewer image artifacts (P < .001) and better overall diagnostic quality (P < .001). Although the 10-minute MPRAGE sequence showed a tendency to have more artifacts than the standard sequence (P = .08), the overall diagnostic quality was similar (P = .66). Moreover, there was no statistically significant difference in the diagnostic performance between the protocols. The sensitivity, specificity, and accuracy values for the 10-minute protocol were 100.0%, 88.9%, and 98.1%.

CONCLUSIONS: The 10-minute brain MR imaging protocol with contrast is comparable in diagnostic performance with the standard protocol in an inpatient motion-prone population, with the additional benefits of reducing acquisition times and image artifacts.

ABBREVIATIONS:

GRAPPA
generalized autocalibrating partially parallel acquisition
GRE
gradient-echo
SE
spin-echo

The prolonged acquisition time of MR imaging is uncomfortable for patients, introduces the potential for motion-related artifacts (especially in critically ill patients), limits clinical availability, and increases cost. Consequently, in the past decade, there has been a concerted effort to develop fast and ultrafast MR imaging protocols.1⇓⇓⇓⇓⇓–7

For many years, continual development of new scanners with stronger gradients and the improvement of coil technology,8⇓–10 allied with a number of emerging fast imaging techniques, has allowed substantial reduction in MR imaging scan times.1,11⇓–13 More recently, the development of parallel imaging, a robust method for accelerating MR imaging data acquisitions based on obtaining simultaneous information from arrays of coils, allowing decreased filling of k-space lines, has been the preferred method for decreasing acquisition times.14⇓–16

This study is in accord with recent effort within the neuroradiology research community to accelerate the clinical MR imaging studies and expands on a 5-minute noncontrast brain MR imaging protocol previously validated by our group.11 We previously demonstrated similar image quality and diagnostic accuracy of a 5-minute brain MR imaging protocol compared with the conventional protocol in a motion-prone clinical population. The aim of this study was to develop a 10-minute gadolinium-enhanced brain MR imaging protocol with accelerated sequences and to evaluate its diagnostic performance compared with a standard clinical protocol in a similar clinical population.

Materials and Methods

Study Design

A prospective comparative study was performed in 69 consecutive neurologic/neurosurgical patients in the intensive care unit who underwent brain MR imaging with contrast, from February through June 2016. None of the patients were sedated. Sixteen patients were excluded because of incomplete datasets due to technical or compliance issues. The remaining 53 patients (25 men; mean age, 53.4 ± 16.1 years) were included. Demographic information, including age, sex, and clinical indication for undergoing MR imaging, is described in Table 1. This study was Health Insurance Portability and Accountability Act–compliant and was approved by the Massachusetts General Hospital institutional review board. Because all brain MR imaging studies included were acquired for clinical purposes and no significant time was added to the study, informed consent was waived by the institutional review board.

View this table:
  • View inline
  • View popup
Table 1:

Clinical characteristics of patients

MR Imaging Protocol

All studies included 5 basic fast sequences that have been previously validated (5-minute brain)11 and standard and fast versions of 2 common clinically used postcontrast sequences: axial 5-mm T1-weighted and 3D MPRAGE. Because the acquisition time of the precontrast sequences in addition to the fast postcontrast sequences was close to 10 minutes, we decided to call this novel protocol the “10-minute brain MR imaging protocol.” All MR imaging studies were performed with a clinical 3T MR imaging scanner (Magnetom Skyra; Siemens, Erlangen, Germany) with maximum gradient strength of 45 mT/m, a slew rate of 200 T/m/s, and a 32-channel multiarray receiver head coil. All scans began with 4 sequences from the 5-minute brain protocol (fast sagittal T1-weighted, axial FLAIR, axial T2*-weighted, and axial diffusion-weighted images),11 followed by a fast gradient-echo (GRE) T1-weighted sequence. Following the intravenous injection of gadolinium, an axial T2-weighted sequence, also developed for the 5-minute protocol, was performed to allow a minimum time required for the contrast to properly enhance brain lesions.17 The standard axial TSE T1-weighted, 10-minute protocol fast axial GRE T1-weighted, and standard and accelerated MPRAGE sequences were then acquired in a randomized order. The fast axial GRE T1 and fast MPRAGE sequences were shortened with generalized autocalibrating partially parallel acquisition (GRAPPA).18 In addition, manual intersequence adjustments were eliminated with the automatic section positioning technique. This technique was developed by van der Kouwe et al,19 with a probabilistic method to align a 3D localizer to a statistical atlas, which contains the probability of a given tissue type occurring at a given location based on the MR imaging intensity values.

A detailed summary of sequence parameters is found in the On-line Table. The elapsed times before the beginning of each sequence were measured and compared between both protocols (standard and 10-minute). Elapsed time was defined as a time from the start of the MR imaging study (localizer scan) to the start of each sequence in each protocol.11

Qualitative Image Evaluation

The DICOM datasets were transferred to a predetermined workstation and anonymized before randomization. Blinded to patient information and protocol type, 2 neuroradiologists (O.R., S.Y.H.) with 16 and 6 years of experience independently reviewed all DICOM datasets with a DICOM viewer (OsiriX Imaging Software; http://www.osirix-viewer.com). To obtain optimal visualization, we allowed adjustments of window widths and levels. A research team member not involved in the data assessment was responsible for maintaining anonymization and randomization keys.

Individual Analysis

Regarding the individual analysis, each patient had 2 DICOM datasets: 1 containing the 10-minute postcontrast protocol and 1 containing the standard protocol images (both shared the same 5 basic sequences from the 5-minute brain protocol already mentioned and a standard precontrast 5-mm axial T1-weighted sequence). Both datasets were distributed in a randomized fashion throughout the reading sessions so that no patient had his or her standard and 10-minute protocols read at the same session.

Individual datasets for each protocol were assessed for diagnostic performance, and accuracy was calculated with the standard protocol as the criterion standard. The readers were asked to determine the number of lesions, the degree of enhancement, and the presumed diagnosis (without knowledge of clinical information) after they analyzed the entire protocol. Only pathological enhancing lesions were included. The degree of enhancement was determined on the basis of a predefined 4-point scale: 0 (none), not visualized on 1 (or both) of the postcontrast sequences; 1 (subtle), faintly visualized on 3D sequences but better visualized on axial images (or vice versa); 2 (adequate), moderate degree of enhancement, equally seen in both 3D and axial sequences; and 3 (excellent), strong and sharply demarcated enhancement on both sequences.20 Disagreements between readers were resolved by consensus review for presumed diagnoses and adjudicated by a third reader (P.S.) with 20 years of experience for the remaining variables.

Head-to-Head Analysis

A separate review session was performed to compare the presence of image artifacts, visualization of normal anatomic structures, and overall diagnostic quality. Each case had side-by-side comparison of the standard and 10-minute versions of the T1-weighted axial postcontrast sequences and side-by-side comparison of the standard and 10-minute versions of the MPRAGE postcontrast sequences. Both datasets (10-minute and standard) were presented simultaneously in a random left-right order and in a blinded fashion to the observers. The observers documented which sequence was superior (left or right) or whether they were equivalent. A different member of the research team, who was not blinded to the assignments, used these scores and rearranged them following a previously described scoring method.21 A third reader (P.S.) resolved any disagreements. Image quality was defined as image degradation by artifacts and was assessed by using a 5-point scale: −2, artifacts are seen only on the left sequence; −1, artifacts are worse on the left sequence; 0, comparable artifacts are seen in both protocols; +1, artifacts are worse on the right sequence; +2, artifacts are seen only on the right sequence. The overall diagnostic quality was defined as the ability to identify findings despite the presence of artifacts and was assessed by a similar comparative 5-point scale: −2, left sequences are nondiagnostic; −1, right sequences are superior to the left sequences, but both are diagnostic; 0, both protocols are diagnostic and equal in terms of overall quality; +1, left sequences are superior to the 10-minute sequences, but both are diagnostic; +2, right sequences are nondiagnostic.21

Statistical Analysis

The descriptive data were presented by means and SDs or medians and ranges for parametric and nonparametric variables, respectively. Fisher exact and Wilcoxon signed rank tests were used to analyze the results of elapsed time, head-to-head, and individual analyses, considering categoric and continuous variables, respectively, on the basis of the data from the described scores after the adjudication. The comparison of individual analyses regarding the diagnostic performance was evaluated with the McNemar test.

Proportions of agreement between readers regarding the individual analysis were reported with the Cohen κ coefficient. This coefficient was interpreted as follows: 0.00–0.20, slight agreement; 0.21–0.40, fair agreement; 0.41–0.60, moderate agreement; 0.61–0.80, substantial agreement; and >0.80, almost perfect agreement.22

P values < .05 were considered statistically significant. All statistical calculations were performed with STATA, Version 14.0 (StataCorp, College Station, Texas).

Results

Elapsed-Time Comparison

There was no statistically significant difference between the elapsed time of the standard and 10-minute sequences (P > .05). These results reinforce the order of the scanning being truly randomized, and they did not influence image quality.

Individual Analysis

The observers decided by consensus a presumed diagnosis based on the MR imaging features (Table 2). These diagnoses were concordant between the 10-minute and standard protocol groups in 52 cases (98.1%). The only case in which they disagreed was diagnosed as a vascular pathology in the standard protocol sequences, but it was considered normal vascular enhancement in the 10-minute protocol. Retrospectively, this lesion was present in the 10-minute protocol sequences and was compatible with a small capillary telangiectasia. The sensitivity, specificity, and accuracy of the 10-minute protocol were 100.0% (95% CI, 92%–100%), 88.9% (95% CI, 51.8%–99.7%), and 98.1% (95% CI, 89.9%–99.9%), respectively.

View this table:
  • View inline
  • View popup
Table 2:

Presumed diagnosis based on imaging findings without clinical information

Regarding the enhancing lesions, the median number and statistical distribution of the lesions for each group were similar. The observers identified the same number of lesions in both protocols (162 lesions in 45 patients). From these 45 patients in whom the presence of at least 1 enhancing lesion was described, 18 (40%) underwent the standard protocol first, and 27 (60%), the 10-minute protocol first. Just 1 lesion was more conspicuous in the standard protocol but was also identified on the 10-minute protocol sequences. In this particular case, the standard postcontrast sequences were acquired after the 10-minute postcontrast sequences, and the increased leakage of gadolinium within the lesion may explain this difference. The κ for the interobserver agreement was 0.96 for the standard sequences and 1.0 for the 10-minute sequences. The observers classified slightly more lesions with a higher degree of enhancement in the 10-minute sequences; 97 lesions were classified as degree 3 in the standard protocol, while 111 lesions were classified as degree 3 in the 10-minute protocol (P < .001). The κ for the interobserver agreement for this variable was 0.71 for the standard sequences and 0.70 for the 10-minute sequences.

Head-to-Head Analysis

The 10-minute axial GRE T1-weighted postcontrast sequence was considered superior (in terms of the presence of artifacts and overall diagnostic quality) compared with the standard postcontrast spin-echo (SE) T1-weighted sequence. For most cases (51/53) (96.2%), the 10-minute GRE T1-weighted sequence had fewer artifacts compared with the standard SE T1-weighted sequence (P < .001) (Table 3 and Fig 1).

View this table:
  • View inline
  • View popup
Table 3:

Head-to-head evaluation

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Postcontrast T1-weighted axial images obtained from a 66-year-old woman with a history of non-small cell lung cancer showing a metastatic cystic lesion with peripheral enhancement in the right cerebellar hemisphere. Precontrast axial GRE T1-weighted (A), postcontrast axial GRE T1-weighted (B), and postcontrast axial SE T1-weighted (C) images. The 10-minute axial GRE T1WI shows fewer artifacts compared with the standard axial TSE T1WI. The conspicuity of the lesion is comparable on both postcontrast sequences.

Most of the MPRAGE postcontrast evaluations reported that the sequences were equivalent. However, there was a trend among the observers to find more artifacts on the 10-minute sequence, though the difference was not statistically significant (P = .08). The presence of these artifacts did not influence the overall diagnostic quality (P = .66) (Fig 2).

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Sagittal postcontrast MPRAGE images from a 53-year-old woman with history of breast cancer showing postoperative findings after resection of a brain metastasis. Ten-minute sagittal 3D MPRAGE (A) and standard sagittal 3D MPRAGE (B) images both show comparable diagnostic quality.

Discussion

Our results suggest that the proposed 10-minute contrast-enhanced protocol may improve imaging of motion-prone patients in an inpatient setting. We demonstrated that an optimized 10-minute protocol with contrast (sagittal T1-weighted, axial T2-weighted, axial FLAIR, axial T2*WI, axial DWI, axial T1-weighted pre- and postcontrast, and 3D-MPRAGE postcontrast) has similar diagnostic accuracy and diagnostic image quality compared with a conventional postcontrast MR imaging protocol.

In fact, the 10-minute GRE T1-weighted axial postcontrast sequence performed better in terms of artifacts and diagnostic image quality compared with the standard SE T1-weighted postcontrast sequence. One reason for this difference in performance could be due to intrinsic differences in these pulse sequences, resulting in faster acquisition times and less motion artifacts with GRE sequences. However, even the initial studies >2 decades ago reported that SE sequences showed more contrast compared with GRE.23 The improvements in scanner hardware and the higher field strengths of the 3T scanners might have helped to reduce this difference in contrast. Another contribution of our findings is that the TE of the GRE sequence is almost 3 times shorter than the TE of the SE sequence, which could also reduce pulsation artifacts.24

The 10-minute-protocol MPRAGE sequence had similar diagnostic performance compared with the standard sequence, though it had a non-statistically significant trend to present more artifacts. The likely cause is the reduction in the signal-to-noise ratio, typical of parallel imaging, which is more evident in 3D sequences.25,26 Nevertheless, having no influence on the diagnostic performance and the decrease in the acquisition time may justify the use of this sequence.

The shortened acquisition time is one of the most significant benefits of the 10-minute protocol, especially in a group of unstable and motion-prone patients as seen in our cohort. The scan time of our 10-minute protocol was 10 minutes and 15 seconds compared with at least 19 minutes and 3 seconds for a typical conventional protocol (without using acceleration techniques, even for the precontrast sequences), which represents an acquisition time reduction of almost 50%. The acquisition time of the combined postcontrast sequences (GRE T1-weighted axial and 3D MPRAGE) in the 10-minute protocol was 3 minutes and 36 seconds compared with 7 minutes and 49 seconds for the standard postcontrast sequences. This reduction was possible without compromising diagnostic performance and maintaining an accuracy of almost 100%.

We decided to maintain both sequences, 2D T1-weighted axial and 3D MPRAGE, to increase our sensitivity for the detection of enhancing lesions and to be in agreement with the standard protocol in our department, which includes 2 different T1-weighted sequences after contrast administration. Considering the clinical importance of the postcontrast sequences in this population, we believe that maintaining both sequences is useful in case of patient movement during the MR imaging acquisition. While the 3D MPRAGE is known to have higher spatial resolution compared with 2D sequences, it may have decreased the conspicuity of enhancement for small lesions in some cases, supporting the complementary use of both sequences.27,28

Parallel imaging relies on a more efficient scan technique, which uses a higher percentage of the scan time for data acquisition (instead of image reconstruction). More specifically, multiple independent receiver coils are used, and the spatial information provided by these independent coils is exploited to encode multiple MR imaging echoes simultaneously.15,18 Although parallel imaging has many advantages, it has an SNR penalty. Our protocol is optimized for 3T MR imaging with a 32-channel head coil to compensate and mitigate these constraints16 and should be adapted if 1.5T scanners or head coils with fewer channels are used.

In accordance with our results, previous studies demonstrated the benefits of using parallel imaging sequences in ischemic stroke and pediatric central nervous system disorders,3,29,30 with consistently reduced acquisition times and comparable image quality. In the study of Nael et al,29 postcontrast sequences, MR angiography and dynamic susceptibility contrast perfusion, were tested in an acute stroke setting. This study used echo-planar imaging as an acceleration factor for most sequences and yet reached a similar accuracy between the fast and conventional protocols. Our previous study demonstrated the feasibility of fast sequences without contrast in an inpatient setting, with comparable diagnostic accuracy with standard sequences for multiple CNS pathologies in an adult population.11 Our current results with postcontrast sequences reinforced and expanded on those findings.

Our study has several limitations. First, it included a relatively small sample size. Although we enrolled only 53 patients, we were able to compare the enhancement pattern of >160 lesions. Second, we decided to use our standard protocol as the criterion standard, which may overestimate the accuracy of the protocols. Third, the time lag between the reading sections was imprecise, increasing the risk of reader-order bias. To address this issue, we performed assessments separated by at least 1 week from each other in a random order.31 Fourth, our analysis was predominantly qualitative and subjective rather than with quantitative and automated measures. Nevertheless, our κ coefficients for interobserver agreement for enhancement characteristics and the number of lesions were in the range of substantial-to-near-complete agreement, and the diagnostic concordant rate between the standard and 10-minute protocols was very high (98.1%).

Conclusions

The 10-minute brain MR imaging protocol with contrast is at least comparable with the standard protocol in an inpatient motion-prone clinical setting, with the substantial benefit of reducing the acquisition time (by nearly 50%). Further use of this protocol in larger and different patient populations is warranted to determine the extent of its clinical utility.

Footnotes

  • Disclosures: Joana Fagundes—RELATED: Consulting Fee or Honorarium: Siemens Medical Solutions USA, Comments: scholarship to conduct the research. Maria Gabriela Longo—RELATED: Consulting Fee or Honorarium: Siemens Medical Solution USA, Comments: scholarship to conduct the research. Keith Heberlein—UNRELATED: Employment: Siemens Medical Solution USA, Comments: I am a full-time employee. Ramon G. Gonzalez—UNRELATED: Expert Testimony: For the US Attorney in Florida.

  • J. Fagundes, M.G. Longo, and K. Heberlein received financial support from Siemens Medical Solutions.

  • This work was conducted with support from Harvard Catalyst and The Harvard Clinical and Translational Science Center (National Center for Research Resources and the National Center for Advancing Translational Sciences, National Institutes of Health Award UL1 TR001102) and financial contributions from Harvard University and its affiliated academic health care centers.

  • The content is solely the responsibility of the authors and does not necessarily represent the official views of Harvard Catalyst, Harvard University and its affiliated academic health care centers, or the National Institutes of Health.

References

  1. 1.↵
    1. Tsao J
    . Ultrafast imaging: principles, pitfalls, solutions, and applications. J Magn Reson Imaging 2010;32:252–66 doi:10.1002/jmri.22239 pmid:20677249
    CrossRefPubMed
  2. 2.↵
    1. Heidemann RM,
    2. Ozsarlak O,
    3. Parizel PM, et al
    . A brief review of parallel magnetic resonance imaging. Eur Radiol 2003;13:2323–37 doi:10.1007/s00330-003-1992-7 pmid:12942278
    CrossRefPubMed
  3. 3.↵
    1. Woodfield J,
    2. Kealey S
    . Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review. Pediatr Radiol 2015;45:1271–81 doi:10.1007/s00247-015-3333-9 pmid:25820342
    CrossRefPubMed
  4. 4.↵
    1. Bilgic B,
    2. Gagoski BA,
    3. Cauley SF, et al
    . Wave-CAIPI for highly accelerated 3D imaging. Magn Reson Med 2015;73:2152–62 doi:10.1002/mrm.25347 pmid:24986223
    CrossRefPubMed
  5. 5.↵
    1. Jacobs J,
    2. Stich J,
    3. Zahneisen B, et al
    . Fast fMRI provides high statistical power in the analysis of epileptic networks. Neuroimage 2014;88:282–94 doi:10.1016/j.neuroimage.2013.10.018 pmid:24140936
    CrossRefPubMed
  6. 6.↵
    1. Geethanath S,
    2. Reddy R,
    3. Konar AS, et al
    . Compressed sensing MRI: a review. Crit Rev Biomed Eng 2013;41:183–204 doi:10.1615/CritRevBiomedEng.2014008058 pmid:24579643
    CrossRefPubMed
  7. 7.↵
    1. Ma D,
    2. Gulani V,
    3. Seiberlich N, et al
    . Magnetic resonance fingerprinting. Nature 2013;495:187–92 doi:10.1038/nature11971 pmid:23486058
    CrossRefPubMed
  8. 8.↵
    1. Wiggins GC,
    2. Polimeni JR,
    3. Potthast A, et al
    . 96-channel receive-only head coil for 3 Tesla: design optimization and evaluation. Magn Reson Med 2009;62:754–62 doi:10.1002/mrm.22028 pmid:19623621
    CrossRefPubMed
  9. 9.↵
    1. Wiggins GC,
    2. Triantafyllou C,
    3. Potthast A, et al
    . 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006;56:216–23 doi:10.1002/mrm.20925 pmid:16767762
    CrossRefPubMed
  10. 10.↵
    1. Keil B,
    2. Blau JN,
    3. Biber S, et al
    . A 64-channel 3T array coil for accelerated brain MRI. Magn Reson Med 2013;70:248–58 doi:10.1002/mrm.24427 pmid:22851312
    CrossRefPubMed
  11. 11.↵
    1. Prakkamakul S,
    2. Witzel T,
    3. Huang S, et al
    . Ultrafast brain MRI: clinical deployment and comparison to conventional brain MRI at 3T. J Neuroimaging 2016;26:503–10 doi:10.1111/jon.12365 pmid:27273370
    CrossRefPubMed
  12. 12.↵
    1. Feinberg DA,
    2. Moeller S,
    3. Smith SM, et al
    . Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging. PLoS One 2010;5:e15710 doi:10.1371/journal.pone.0015710 pmid:21187930
    CrossRefPubMed
  13. 13.↵
    1. Feinberg DA,
    2. Setsompop K
    . Ultra-fast MRI of the human brain with simultaneous multi-slice imaging. J Magn Reson 2013;229:90–100 doi:10.1016/j.jmr.2013.02.002 pmid:23473893
    CrossRefPubMed
  14. 14.↵
    1. Deshmane A,
    2. Gulani V,
    3. Griswold MA, et al
    . Parallel MR imaging. J Magn Reson Imaging 2012;36:55–72 doi:10.1002/jmri.23639 pmid:22696125
    CrossRefPubMed
  15. 15.↵
    1. Yanasak NE,
    2. Kelly MJ
    . MR imaging artifacts and parallel imaging techniques with calibration scanning: a new twist on old problems. Radiographics 2014;34:532–48 doi:10.1148/rg.342135051 pmid:24617696
    CrossRefPubMed
  16. 16.↵
    1. Zhu Y,
    2. Hardy CJ,
    3. Sodickson DK, et al
    . Highly parallel volumetric imaging with a 32-element RF coil array. Magn Reson Med 2004;52:869–77 doi:10.1002/mrm.20209 pmid:15389961
    CrossRefPubMed
  17. 17.↵
    1. Akeson P,
    2. Nordström C,
    3. Holtås S
    . Time-dependency in brain lesion enhancement with gadodiamide injection. Acta Radiol 1997;38:19–24 pmid:9059396
    CrossRefPubMed
  18. 18.↵
    1. Griswold MA,
    2. Jakob PM,
    3. Heidemann RM, et al
    . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202–10 doi:10.1002/mrm.10171 pmid:12111967
    CrossRefPubMed
  19. 19.↵
    1. van der Kouwe AJ,
    2. Benner T,
    3. Fischl B, et al
    . On-line automatic slice positioning for brain MR imaging. Neuroimage 2005;27:222–30 doi:10.1016/j.neuroimage.2005.03.035 pmid:15886023
    CrossRefPubMed
  20. 20.↵
    1. Gutierrez JE,
    2. Rosenberg M,
    3. Seemann J, et al
    . Safety and efficacy of gadobutrol for contrast-enhanced magnetic resonance imaging of the central nervous system: results from a multicenter, double-blind, randomized, comparator study. Magn Reson Insights 2015;8:1–10 doi:10.4137/MRI.S19794 pmid:25922578
    CrossRefPubMed
  21. 21.↵
    1. Soman S,
    2. Holdsworth SJ,
    3. Barnes PD, et al
    . Improved T2* imaging without increase in scan time: SWI processing of 2D gradient echo. AJNR Am J Neuroradiol 2013;34:2092–97 doi:10.3174/ajnr.A3595 pmid:23744690
    Abstract/FREE Full Text
  22. 22.↵
    1. Viera AJ,
    2. Garrett JM
    . Understanding interobserver agreement: the kappa statistic. Fam Med 2005;37:360–63 pmid:15883903
    PubMed
  23. 23.↵
    1. Chappell PM,
    2. Pelc NJ,
    3. Foo TK, et al
    . Comparison of lesion enhancement on spin-echo and gradient-echo images. AJNR Am J Neuroradiol 1994;15:37–44 pmid:8141064
    Abstract/FREE Full Text
  24. 24.↵
    1. Crombé A,
    2. Saranathan M,
    3. Ruet A, et al
    . MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T. AJNR Am J Neuroradiol 2015;36:501–07 doi:10.3174/ajnr.A4152 pmid:25376810
    Abstract/FREE Full Text
  25. 25.↵
    1. Li T,
    2. Mirowitz SA
    . Comparative study of fast MR imaging: quantitative analysis on image quality and efficiency among various time frames and contrast behaviors. Magn Reson Imaging 2002;20:471–78 doi:10.1016/S0730-725X(02)00527-1 pmid:12361794
    CrossRefPubMed
  26. 26.↵
    1. Li T,
    2. Mirowitz SA
    . Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts. Magn Reson Imaging 2003;21:745–53 doi:10.1016/S0730-725X(03)00173-5 pmid:14559339
    CrossRefPubMed
  27. 27.↵
    1. Rand S,
    2. Maravilla KR,
    3. Schmiedl U
    . Lesion enhancement in radio-frequency spoiled gradient-echo imaging: theory, experimental evaluation, and clinical implications. AJNR Am J Neuroradiol 1994;15:27–35 pmid:8141062
    Abstract/FREE Full Text
  28. 28.↵
    1. Mugler JP 3rd.,
    2. Brookeman JR
    . Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences. J Magn Reson Imaging 1993;3:761–69 doi:10.1002/jmri.1880030512 pmid:8400563
    CrossRefPubMed
  29. 29.↵
    1. Nael K,
    2. Khan R,
    3. Choudhary G, et al
    . Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries. Stroke 2014;45:1985–91 doi:10.1161/STROKEAHA.114.005305 pmid:24916906
    Abstract/FREE Full Text
  30. 30.↵
    1. Meshksar A,
    2. Villablanca JP,
    3. Khan R, et al
    . Role of EPI-FLAIR in patients with acute stroke: a comparative analysis with FLAIR. AJNR Am J Neuroradiol 2014;39:878–83 doi:10.3174/ajnr.A3786 pmid:24335543
    CrossRefPubMed
  31. 31.↵
    1. Sica GT
    . Bias in research studies. Radiology 2006;238:780–89 doi:10.1148/radiol.2383041109 pmid:16505391
    CrossRefPubMed
  • Received March 6, 2017.
  • Accepted after revision May 12, 2017.
  • © 2017 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 38 (9)
American Journal of Neuroradiology
Vol. 38, Issue 9
1 Sep 2017
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer, O. Rapalino
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
American Journal of Neuroradiology Sep 2017, 38 (9) 1689-1694; DOI: 10.3174/ajnr.A5293

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer, O. Rapalino
American Journal of Neuroradiology Sep 2017, 38 (9) 1689-1694; DOI: 10.3174/ajnr.A5293
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings
  • Usefulness of Wave-CAIPI for Postcontrast 3D T1-SPACE in the Evaluation of Brain Metastases
  • Crossref (17)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Highly‐accelerated volumetric brain examination using optimized wave‐CAIPI encoding
    Daniel Polak, Stephen Cauley, Susie Y. Huang, Maria Gabriela Longo, John Conklin, Berkin Bilgic, Ned Ohringer, Esther Raithel, Peter Bachert, Lawrence L. Wald, Kawin Setsompop
    Journal of Magnetic Resonance Imaging 2019 50 3
  • Practical Considerations for Radiologists in Implementing a Patient-friendly MRI Experience
    Murat Alp Oztek, Christina L. Brunnquell, Michael N. Hoff, Daniel J. Boulter, Mahmud Mossa-Basha, Luke H. Beauchamp, David L. Haynor, Xuan V. Nguyen
    Topics in Magnetic Resonance Imaging 2020 29 4
  • Contrast-to-Dose Relationship of Gadopiclenol, an MRI Macrocyclic Gadolinium-based Contrast Agent, Compared with Gadoterate, Gadobenate, and Gadobutrol in a Rat Brain Tumor Model
    Philippe Robert, Véronique Vives, Anne-Laure Grindel, Stéphane Kremer, Guillaume Bierry, Gaelle Louin, Sébastien Ballet, Claire Corot
    Radiology 2020 294 1
  • Artificial intelligence in multiparametric magnetic resonance imaging: A review
    Cheng Li, Wen Li, Chenyang Liu, Hairong Zheng, Jing Cai, Shanshan Wang
    Medical Physics 2022 49 10
  • Diagnostic performance of a new multicontrast one‐minute full brain exam (EPIMix) in neuroradiology: A prospective study
    Anna F. Delgado, Annika Kits, Jessica Bystam, Magnus Kaijser, Mikael Skorpil, Tim Sprenger, Stefan Skare
    Journal of Magnetic Resonance Imaging 2019 50 6
  • Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study
    Kyeong Hwa Ryu, Dae Seob Choi, Hye Jin Baek, Soo Buem Cho, Ji Young Ha, Tae Byeong Kim, Moon Jung Hwang
    Journal of Neurology 2019 266 2
  • Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Thomas Sartoretti, Elisabeth Sartoretti, Luuk van Smoorenburg, Árpád Schwenk, Manoj Mannil, Nicole Graf, Christoph A. Binkert, Michael Wyss, Sabine Sartoretti-Schefer
    Investigative Radiology 2020 55 12
  • Diagnostic equivalency of fast T2 and FLAIR sequences for pediatric brain MRI: a pilot study
    Camilo Jaimes, Edward Yang, Pauline Connaughton, Caroline D. Robson, Richard L. Robertson
    Pediatric Radiology 2020 50 4
  • Modern acceleration in musculoskeletal MRI: applications, implications, and challenges
    Jan Vosshenrich, Gregor Koerzdoerfer, Jan Fritz
    Skeletal Radiology 2024 53 9
  • Evaluation of the Aggregated Time Savings in Adopting Fast Brain MRI Techniques for Outpatient Brain MRI
    Min Lang, Samuel Cartmell, Azadeh Tabari, Daniel Briggs, Oleg Pianykh, John Kirsch, Stephen Cauley, Wei-Ching Lo, Seretha Risacher, Augusto Goncalves Filho, Marc D Succi, Otto Rapalino, Pamela Schaefer, John Conklin, Susie Y Huang
    Academic Radiology 2023 30 2

More in this TOC Section

  • Diagnostic Neuroradiology of Monoclonal Antibodies
  • Clinical Outcomes After Chiari I Decompression
  • Segmentation of Brain Metastases with BLAST
Show more Adult Brain

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire