Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticleHead & Neck

Improved Assessment of Middle Ear Recurrent Cholesteatomas Using a Fusion of Conventional CT and Non-EPI-DWI MRI

F. Felici, U. Scemama, D. Bendahan, J.-P. Lavieille, G. Moulin, C. Chagnaud, M. Montava and A. Varoquaux
American Journal of Neuroradiology September 2019, 40 (9) 1546-1551; DOI: https://doi.org/10.3174/ajnr.A6141
F. Felici
aFrom the Department of Medical Imaging (F.F., U.S., G.M., C.C., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for F. Felici
U. Scemama
aFrom the Department of Medical Imaging (F.F., U.S., G.M., C.C., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for U. Scemama
D. Bendahan
cNorth Hospital, and CNRS, CRMBM-CEMEREM UMR 7339, 13385 (D.B., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for D. Bendahan
J.-P. Lavieille
bLa Conception University Hospital, Department of Otorhinolaryngology–Head and Neck Surgery (J.-P.L., M.M.)
dUMRT 24 IFSTTAR (J.-P.L., M.M.), Aix-Marseille University, Marseille, France.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.-P. Lavieille
G. Moulin
aFrom the Department of Medical Imaging (F.F., U.S., G.M., C.C., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for G. Moulin
C. Chagnaud
aFrom the Department of Medical Imaging (F.F., U.S., G.M., C.C., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C. Chagnaud
M. Montava
bLa Conception University Hospital, Department of Otorhinolaryngology–Head and Neck Surgery (J.-P.L., M.M.)
dUMRT 24 IFSTTAR (J.-P.L., M.M.), Aix-Marseille University, Marseille, France.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M. Montava
A. Varoquaux
aFrom the Department of Medical Imaging (F.F., U.S., G.M., C.C., A.V.)
cNorth Hospital, and CNRS, CRMBM-CEMEREM UMR 7339, 13385 (D.B., A.V.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Varoquaux
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Recurrent middle ear cholesteatomas are commonly preoperatively assessed using MR imaging (non-EPI-DWI) and CT. Both modalities are used with the aim of distinguishing scar tissue from cholesteatoma and determining the extent of bone erosions. Inflammation and scar tissue associated with the lesions might hamper a proper delineation of the corresponding extensions on CT images. Using surgical findings as the criterion standard, we assessed the recurrent middle ear cholesteatoma extent using either uncoregistered or fused CT–MR imaging datasets and determined the corresponding accuracy and repeatability.

MATERIALS AND METHODS: Twenty consecutive patients with suspected recurrent middle ear cholesteatoma and preoperative CT–MR imaging datasets were prospectively included. A double-blind assessment and coregistration of the recurrent middle ear cholesteatoma extent and manual delineation of 18 presumed recurrent middle ear cholesteatomas were performed by 2 radiologists and compared with the criterion standard. “Reliability score” was defined to qualify radiologists' confidence. For each volume, segmentation repeatability was assessed on the basis of intraclass correlation coefficient and overlap indices.

RESULTS: For the whole set of patients, recurrent middle ear cholesteatoma was further supported by surgical results. Two lesions were excluded from the analysis, given that MR imaging did not show a restricted diffusion. Lesions were accurately localized using the fused datasets, whereas significantly fewer lesions (85%) were correctly localized using uncoregistered images. Reliability scores were larger for fused datasets. Segmentation repeatability showed an almost perfect intraclass correlation coefficient regarding volumes, while overlaps were significantly lower in uncoregistered (52%) compared with fused (60%, P < .001) datasets.

CONCLUSIONS: The use of coregistered CT–MR images significantly improved the assessment of recurrent middle ear cholesteatoma with a greater accuracy and better reliability and repeatability.

ABBREVIATIONS:

FD
fused dataset
ICC
intraclass correlation coefficient
JI
Jaccard index
MEC
middle ear cholesteatoma
rMEC
recurrent MEC
ROC
receiver operating characteristic
UD
uncoregistered dataset
VIBE
volumetric interpolated brain examination

Recurrent middle ear cholesteatoma (rMEC) is a destructive and expanding lesion1 that can recur after a seemingly complete surgical resection. The frequency of rMEC ranges from 5% to 15% and can reach up to 61%2 after an initial operation, particularly with canal wall up techniques. Potential clinical consequences are similar to those resulting from a primary lesion—that is, hearing loss, meningitis, brain abscess, and labyrinthitis. However, the clinical presentation of rMEC differs from that of middle ear cholesteatoma (MEC) regarding otoscopic assessments. A high rate of false-negative results has been reported, so an additional surgical procedure has often been performed as a diagnostic confirmation.3,4 CT is commonly used to assess rMEC, plan revision surgery, and choose middle ear repair strategies.5 Endoscopic (transmastoid or transcanal) or microscopic (canal wall up/down) procedures have been used.6

In the past decade, MR imaging and, more particularly, DWI have been proposed as an alternative to the additional surgical procedure.7 Restricted diffusion in lesions of the middle ear cavity has been reported as a sensitive index of rMEC and false-negative results—that is, missed lesions have been related to small volume or mural cholesteatomas and susceptibility artifacts. Assessment of rMEC using non-EPI-DWI would be more accurate with the ability to detect 3-mm rMEC lesions.7,8

High-resolution CT has been considered so far as the imaging technique of choice for the evaluation of bone tissue changes occurring in rMEC. Erosions of ossicles and the facial nerve canal, labyrinthine system, or tympanic tegmen have been described.9 However, high-resolution CT assessment of rMEC can be challenged by multiple factors such as postoperative scarring and fluid and cholesterol granulomas around the lesion.

Most interesting, it has been recently suggested that surgical planning of rMEC could be improved when using information from coregistered MR and CT images.10 The corresponding usefulness has not been assessed for rMEC. The main aim of the present study was to assess the added value of DWI–CT fusion for the local assessment of rMEC in a clinical workflow. Volumes of lesions were quantified on fused and unfused datasets and compared using intraclass coefficients and similarity indices.

Materials and Methods

Research Design

This monocentric prospective study was approved by the institutional ethics committee (2015–27/RCAPHM15_0223), performed with Commission Nationale de l'informatique et des Libertés (CNIL) authorization (1879159-v0), and identified under ClinicalTrials.gov as NCT02903550.

Patients

Between August 2015 and August 2016, twenty consecutive patients (7 women and 13 men; mean age, 41.2 years) were prospectively enrolled before an rMEC operation. Each patient had a history of histologically proved MEC and had an initial operation at least a year before the inclusion. Each patient had a presumed rMEC based on the combined analysis of otoscopy, CT, and MR imaging. Patients were included once they provided written informed consent. Exclusion criteria were middle ear infection, gadolinium allergy, pregnancy, non-MR imaging–compatible implants or devices, surgical contraindications, or refusal to participate.

Imaging Protocol

MR imaging acquisitions were performed at 1.5T (Magnetom Amira; Siemens, Erlangen, Germany). Patients lay supine while their head was placed in a standard 16-channel head and neck phased array coil. High-resolution T1WI, T2WI, and non-EPI-DWI were acquired in the coronal and axial planes (Table 1). A 3D volumetric interpolated brain examination (VIBE) T1WI dataset was acquired after gadoterate meglumine injection (0.1 mmol/kg, Dotarem; Guerbet, Aulnay-sous-Bois, France).

View this table:
  • View inline
  • View popup
Table 1:

MR acquisition data

CT was performed using an 80-channel × 0.5 mm multidetector scanner (Aquilion PRIME; Canon Medical, Tokyo, Japan). A single acquisition was performed using routine temporal bone protocols (collimation = 0.5 × 4 mm, 135 kV[peak], 200 mAs, resolution time = 0.75 ms, pitch = 0.75 [detail], acquisition FOV= 150 mm [super small], reconstruction FOV = 80 mm). Images were reconstructed in axial, coronal, and sagittal planes (0.5 × 0.5 mm).

Image Analysis

Both MR and CT images were analyzed using OsiriX Imaging Software (http://www.osirix-viewer.com) by 2 experts (A.V. with 16 years' experience and F.F. with 4 years' experience) who were blinded to the patient's clinical status. Observers performed the image assessment and coregistration independently. rMEC lesions were assessed in 18 middle ear areas using a 5-point Likert scale as follows: 1 = no invasion, 2 = unlikely invasion, 3 = unclear invasion, 4 = highly probable invasion, and 5 = obvious invasion; 22 anatomic locations (Table 2) were predefined by the surgical team.

View this table:
  • View inline
  • View popup
Table 2:

rMEC surgical location findings and MR imaging correspondence

To assess the reproducibility of the manual delineation of the lesions, each expert manually segmented each lesion twice at different times on CT images. The corresponding volumes (vol 1 and vol 2) were quantified using the OsiriX “ROI volume” tool. Lesion segmentation was initially performed on the unfused datasets (uncoregistered dataset [UD]). Then, a rigid coregistration was performed between the 3D-VIBE-T1WI and CT datasets using the OsiriX plugin “Fusion tool.” The ipsi- and contralateral geniculate ganglion and ipsilateral stylomastoid foramen were used as specific landmarks. Fusion quality was defined on the basis of a 4-point quality scale using the distance between the corresponding landmarks with 1, 2, 3, and 4 referring to a distance of 0, <1 mm, between 1 and 2 mm, and >2 mm, respectively. The b=1000 non-EPI-DWI was resliced to the coregistered 3D-VIBE-T2WI and then fused to the CT dataset.

The fused dataset (FD) was analyzed 6 weeks later using the same paradigm and the same predefined anatomic locations. The corresponding volumes were referred as vol 3 and vol 4 for observer 1 and 2, respectively.

Surgical Criterion Standard

Surgical findings were considered as the criterion standard for lesion assessment. Using a Likert scale, we defined findings as negative for scores 1 and 2 and as positive for scores 4 and 5 (Table 2, “UD Exact,” “FD Exact”). In addition, a reliability score was computed as follows: 100% for Likert scores 1 and five; 50% for Likert scores 2 and four; 0% for Likert score 3.

Test–Retest Repeatability

To assess the coregistration process and segmentation repeatability, we performed test-retest for volume measurement. The corresponding intraclass coefficients (ICC) for paired measurements (vol 1 to vol 4) and the overlap between manually segmented volumes of interest were computed. Overlap was quantitatively assessed on a voxel basis using the Jaccard index (JI)11:

  • . JI = (VOIa∩VOIb) / (VOIa∪VOIb),

with VOIa and VOIb being volumes manually segmented in fused datasets.

ICC values were qualified according to Landis and Koch.15 The ICC precision of estimates was defined as previously described using the relative 95% confidence interval.16

Statistical Analyses

The whole set of tests was performed with R statistical and computing software, Version 3.2.0 (http://www.r-project.org/), and a P value < .05 was considered statistically significant.

Quantitative variables are presented as means ± SDs, while categoric variables are presented as frequencies. Paired Mann-Whitney U tests were used to compare exact finding rates, reliability scores, volumes, and segmentation overlap indices computed in UD and FD.

Areas under the receiver operating characteristic (ROC) curve measurements were used to quantify the ability to locate rMEC. The DeLong test12 was used to compare the areas under the curve of the paired ROC curves with the package pROC version 1.14.0 for R. For quantitative variables, the Youden method13 was used to determine the thresholds of the ROC curves.

Single-measure ICCs were calculated using the 2-way random ANOVA on average measures (ICC ranges, 0.00–1.00, with values closer to 1.00 representing better reproducibility).14 Interpretation of the ICC was categorized according to Landis and Koch.15 The precision of ICC estimates was defined as previously described using the 95% CI.16

Results

rMEC Assessment

Among the 20 rMECs, in the 20 patients included in the study, 2 rMEC lesions (11 and 12 mm, respectively) were excluded (Table 3). The corresponding absence of a b=1000 signal on DWI was considered a false-negative finding. A total of 18 lesions were analyzed (Table 2) with respect to 22 anatomic locations (n = 396). Fusion was qualified as “perfect” in 9 lesions (50%) and as “good” (<1 mm) for the remainder. The anatomic distribution of lesions is detailed in Table 2. The epitympanic recess was the usual rMEC site. The frequency of exact findings amounted to 84.8% ± 11.2% using UD and was significantly larger (99.7% ± 11.8%, P < 0.01) using FD. Similarly, the reliability score significantly rose from 84.5% ± 10.3% to 96.2% ± 4.3% (P < 0.01) using UD and FD, respectively (Table 2). The area under the curve value was 0.93 using UD and significantly increased to 0.99 (P < 0.01) using FD (Table 4).

View this table:
  • View inline
  • View popup
Table 3:

Patient data

View this table:
  • View inline
  • View popup
Table 4:

Clinical performance of rMEC local assessment

Segmentation Reproducibility

Mean lesion volume was 0.36 ± 0.42 mL and ranged from 0.01 to 1.73 mL. Inter- and intraobserver volume calculation variability was almost perfect, with the ICC ranging from 0.86 to 0.95 (P < .001, Table 5). The highest ICC (95%) and the best precision (6%) were obtained for the interobserver measurements performed on FD. Intraobserver segmentation overlap (JI) was different between observer 1 (55% ± 23%) and observer 2 (45% ± 27%; P < 0.01). A larger interobserver segmentation overlap (60% ± 28%) was measured for FD compared with UD (52% ± 22%, P < 0.01).

View this table:
  • View inline
  • View popup
Table 5:

Segmentation reproducibility on volume measurements

Discussion

The present results suggest that a better rMEC assessment could be achieved when CT and MR imaging datasets are coregistered and fused. On that basis, both imaging modalities should be considered before an operation.

These results further support and extend those from previous reports that demonstrated the usefulness of FD in the local evaluation of MEC.10,17⇓–19 Accordingly, from a comparative analysis between CT alone and FD, a few studies have suggested that MEC would be better assessed using FD.10,17,19 This result has been further confirmed from a comparative analysis between DWI alone and FD.17⇓–19 The superiority of the FD-based rMEC assessment that we describe in the present study could partly be due to a careful patient selection based on the DWI results, the number of patients, and the number of locations. DWI is an imaging technique that can clearly distinguish cholesteatoma from postsurgical abnormalities such as scars.

In our study, only patients with rMEC were included, and untreated patients were excluded so that the postoperative scar tissue could be addressed. On the contrary, in studies in which untreated patients have been included, this issue could not be addressed,10,17,18 and the advantage of the FD-based assessment could not have been properly investigated. The number of patients with rMEC included in the present study (n = 20) was larger compared with other studies in which 2–16 patients were included.10,17⇓–19 The number of locations could have also been a central methodologic factor. While 4–6 locations have been assessed in previous studies, the 22 locations assessed in the present study likely led to a reduced α risk. In addition, given that each location has been analyzed in each patient, no missing data had to be considered, and cluster analysis was not considered. The increase of exact location findings was most striking in the tegmen antri, anterior epitympanic recess, tympanic segment of the facial nerve, and mesotympanum. These locations have been reported as frequently occurring.19

As previously described, the 5-point Likert scale was used to count exact findings, calculate the reliability score, and compare ROC curves.20 Such a scale has been used in a large number of radiologic studies.21 As an example of the clinical added value of the FD-based rMEC assessment, the carotid canal was affected in one of the patients, and this was missed using the UD, whereas it was identified using FD (Figure). In this particular case, the proper location had an impact on the surgical procedure and the middle ear repair strategy.

FIGURE.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE.

Example of rMEC leading to a carotid canal erosion. Recurrent middle ear cholesteatoma (axial b=1000 non-EPI MR imaging, B, arrow) probably located (rated Likert 4) in the hypotympanum, on uncoregistered dataset (A, B, C, E, arrows). The hypotympanum location is clear (rated Likert 5), considering that the fused dataset (b=1000/CT in axial plane, D, arrow) and the vertical carotid canal lysis (A and D, arrowheads) can be seen. The perioperative surgical findings (F) confirmed the hypotympanum rMEC location (arrows) and the carotid canal lysis (arrowhead). In that case, the presurgical image fusion allowed the surgeon to adapt his approach, thus lowering the surgical risks.

The improved segmentation reproducibility using FD is further supportive of this added value. Scarce data are available in previous studies regarding this particular issue. ICC values regarding computed volumes illustrated an almost perfect agreement for each segmentation. Although no criterion standard measurements were available for volumes, our analysis disclosed reproducible volume measurements based on CT and b=1000 findings. The superior reproducibility of the FD-based assessment was statistically demonstrated using the JI, which has been largely used for volume delineation.11 The JI ranged between 31% and 74%, thereby indicating a poor-to-high overlap between volumes of interest. One has to keep in mind that the JI assessed both segmentation and coregistration processes, given that each observer performed his own fusion process.

During the past decade, non-EPI-DWI has significantly improved the handling of MEC both in terms of diagnosis and postoperative survey strategy.17,22 As recently reported, non-EPI-DWI is less sensitive to susceptibility artifacts and can provide a high signal-to-noise ratio so that high sensitivity (90%) and specificity (94%) can be achieved.7 In the present study, 2 lesions of 20 were freely diffusive, leading to a sensitivity of 90%, in agreement with a recent meta-analysis report.7 The 100% specificity reported in the present study is likely due to particular attention paid to excluding patients with middle ear infection. False-positive findings can be found due to water restriction in infected areas as described in mastoid abscess.23

The choice of the non-EPI-DWI technique in the field of rMEC investigations is still a matter of debate. We chose to use TSE-DWI, considering the recognized low artifacts on the skull base and signal homogeneity.24 HASTE-DWI has been noted for the shorter acquisition time,7 but information regarding artifacts and contrast-to-noise ratio are missing. The usual slice thickness used for non-EPI-DWI sequences ranges from 2 to 4 mm. The recently developed isotropic 1.5-mm slice thickness non-EPI-DWI at 3T can be considered a major advantage offering 3.4-mm3 voxel volumes.10 Such a turbo-field echo with diffusion-sensitized driven-equilibrium recall should be considered in the future for high-resolution MR imaging–CT fusion.10

Registration Process

Registration and fusion processes were performed in a 10-minute clinical workflow using freeware as previously suggested.10,17⇓–19 Because the skull base is a nondeformable structure, a rigid coregistration was used for the merging process of high-resolution cross-sectional imaging datasets. To limit observer subjectivity, we did not directly merge DWI and CT scans using a manual fine-tuning. We chose a multistep process involving the selection of 3 invariable landmarks on the 3D-T1 VIBE MR imaging and CT datasets and a reslicing of the b=1000 stack on the 3D-T1 VIBE MR imaging dataset. On that basis, 50% of the fusions were qualified as perfect and the remainder as good (< 1 mm), which can still be considered clinically valuable. Imperfect fusion quality could be accounted for by patient motion between the 2 acquisitions. Another accounting factor could be related to the variation between the CT scan isomorphism and the MR imaging matrix diffeomorphism, which depends on magnetic susceptibility. Diffeomorphic artifacts are expected to be larger using ultrafast gradient-echo sequences such as VIBE compared with spin-echo (b=1000) sequences. Theses artifacts could lead to minor voxel mismatch between MR imaging and CT datasets. The use of the recently developed spin-echo 3D sequence (sampling perfection with application-optimized contrasts using different flip angle evolution, SPACE; Siemens) might be an interesting alternative to reduce these artifacts.25 In the present cohort, although 2 patients exhibited rMEC lesions as round pearls in an aerated mastoidectomy cavity, the fusion process was qualified as perfect. Other postprocessing techniques could be used in the future with the aim of a fully automatic fusion, which should reduce processing time and manual registration bias.26

Clinical Implications for Patients

The present results disclose and further support the idea that fusion of coregistered images can improve rMEC assessment and help in guiding the surgical procedure. Preoperative surgical approaches and specific surgical risks can be expected to be better evaluated, so new developments in endoscopic ear surgery could be expected as part of a safe surgical approach.27 The exact location of rMEC extensions is of high interest because it should allow minimally invasive surgical procedures without any transmastoid surgery conversion during MEC removal.6

Conclusions

Image fusion between coregistered conventional non-EPI-DWI and temporal bone CT significantly improved the local assessment of recurrent cholesteatoma. Further supportive of this additional value, lesion segmentation between and within observer was improved. The impact on operation duration and postoperative complications should be evaluated in future studies.

Acknowledgments

We acknowledge Yasmina Chaibi (Olea Medical, La Ciotat, France) for her help in data analysis, Professor Richard Nicollas and Dr Brigitte Bourliere for their involvement in patient inclusion, and Professor Jean Gaudard for a thorough review of the statistical section.

REFERENCES

  1. 1.↵
    1. Olszewska E,
    2. Wagner M,
    3. Bernal-Sprekelsen M, et al
    . Etiopathogenesis of cholesteatoma. Eur Arch Otorhinolaryngol 2004;261:6–24 doi:10.1007/s00405-003-0623-x pmid:12835944
    CrossRefPubMed
  2. 2.↵
    1. Kerckhoffs KG,
    2. Kommer MB,
    3. van Strien TH, et al
    . The disease recurrence rate after the canal wall up or canal wall down technique in adults. Laryngoscope 2016;126:980–87 doi:10.1002/lary.25591 pmid:26404516
    CrossRefPubMed
  3. 3.↵
    1. Crowson MG,
    2. Ramprasad VH,
    3. Chapurin N, et al
    . Cost analysis and outcomes of a second-look tympanoplasty-mastoidectomy strategy for cholesteatoma. Laryngoscope 2016;126:2574–79 doi:10.1002/lary.25941 pmid:26928951
    CrossRefPubMed
  4. 4.↵
    1. Vanden Abeele D,
    2. Coen E,
    3. Parizel PM, et al
    . Can MRI replace a second look operation in cholesteatoma surgery? Acta Otolaryngol 1999;119:555–61 doi:10.1080/00016489950180784 pmid:10478595
    CrossRefPubMed
  5. 5.↵
    1. Bennett M,
    2. Wanna G,
    3. Francis D, et al
    . Clinical and cost utility of an intraoperative endoscopic second look in cholesteatoma surgery. Laryngoscope 2018;128:2867–71 doi:10.1002/lary.27258 pmid:30325024
    CrossRefPubMed
  6. 6.↵
    1. Abdul-Aziz D,
    2. Kozin ED,
    3. Lin BM, et al
    . Temporal bone computed tomography findings associated with feasibility of endoscopic ear surgery. Am J Otolaryngol 2017;38:698–703 doi:10.1016/j.amjoto.2017.06.007 pmid:28711236
    CrossRefPubMed
  7. 7.↵
    1. Muzaffar J,
    2. Metcalfe C,
    3. Colley S, et al
    . Diffusion-weighted magnetic resonance imaging for residual and recurrent cholesteatoma: a systematic review and meta-analysis. Clin Otolaryngol 2017;42:536–43 doi:10.1111/coa.12762 pmid:27701821
    CrossRefPubMed
  8. 8.↵
    1. De Foer B,
    2. Vercruysse JP,
    3. Bernaerts A, et al
    . Middle ear cholesteatoma: non–echo-planar diffusion-weighted MR imaging versus delayed gadolinium-enhanced T1-weighted MR imaging—value in detection. Radiology 2010;255:866–72 doi:10.1148/radiol.10091140 pmid:20501723
    CrossRefPubMed
  9. 9.↵
    1. Baráth K,
    2. Huber AM,
    3. Stämpfli P, et al
    . Neuroradiology of cholesteatomas. AJNR Am J Neuroradiol 2011;32:221–29 doi:10.3174/ajnr.A2052 pmid:20360335
    Abstract/FREE Full Text
  10. 10.↵
    1. Yamashita K,
    2. Hiwatashi A,
    3. Togao O, et al
    . High-resolution three-dimensional diffusion-weighted MRI/CT image data fusion for cholesteatoma surgical planning: a feasibility study. Eur Arch Otorhinolaryngol 2015;272:3821–24 doi:10.1007/s00405-014-3467-7 pmid:25543305
    CrossRefPubMed
  11. 11.↵
    1. Hanna GG,
    2. Hounsell AR,
    3. O'Sullivan JM
    . Geometrical analysis of radiotherapy target volume delineation: a systematic review of reported comparison methods. Clin Oncol (R Coll Radiol) 2010;22:515–25 doi:10.1016/j.clon.2010.05.006 pmid:20554168
    CrossRefPubMed
  12. 12.↵
    1. DeLong ER,
    2. DeLong DM,
    3. Clarke-Pearson DL
    . Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988;44:837–45 doi:10.2307/2531595 pmid:3203132
    CrossRefPubMed
  13. 13.↵
    1. Fluss R,
    2. Faraggi D,
    3. Reiser B
    . Estimation of the Youden Index and its associated cutoff point. Biom J 2005;47:458–72 doi:10.1002/bimj.200410135 pmid:16161804
    CrossRefPubMed
  14. 14.↵
    1. Donner A,
    2. Koval JJ
    . The estimation of intraclass correlation in the analysis of family data. Biometrics 1980;36:19–25 pmid:7370372
    CrossRefPubMed
  15. 15.↵
    1. Landis JR,
    2. Koch GG
    . The measurement of observer agreement for categorical data. Biometrics 1977;33:159–74 doi:10.2307/2529310 pmid:843571
    CrossRefPubMed
  16. 16.↵
    1. Varoquaux A,
    2. Rager O,
    3. Lovblad K-O, et al
    . Functional imaging of head and neck squamous cell carcinoma with diffusion-weighted MRI and FDG PET/CT: quantitative analysis of ADC and SUV. Eur J Nucl Med Mol Imaging 2013;40:842–52 doi:10.1007/s00259-013-2351-9 pmid:23436068
    CrossRefPubMed
  17. 17.↵
    1. Locketz GD,
    2. Li PM,
    3. Fischbein NJ, et al
    . Fusion of computed tomography and PROPELLER diffusion-weighted magnetic resonance imaging for the detection and localization of middle ear cholesteatoma. JAMA Otolaryngol Neck Surg 2016;142:947–53 doi:10.1001/jamaoto.2016.1663 pmid:27414044
    CrossRefPubMed
  18. 18.↵
    1. Campos A,
    2. Mata F,
    3. Reboll R, et al
    . Computed tomography and magnetic resonance fusion imaging in cholesteatoma preoperative assessment. Eur Arch Otorhinolaryngol 2017;274:1405–11 doi:10.1007/s00405-016-4415-5 pmid:27921171
    CrossRefPubMed
  19. 19.↵
    1. Plouin-Gaudon I,
    2. Bossard D,
    3. Ayari-Khalfallah S, et al
    . Fusion of MRIs and CT scans for surgical treatment of cholesteatoma of the middle ear in children. Arch Otolaryngol Neck Surg 2010;136:878–83 doi:10.1001/archoto.2010.151 pmid:20855680
    CrossRefPubMed
  20. 20.↵
    1. Desmots F,
    2. Fakhry N,
    3. Mancini J, et al
    . Shear wave elastography in head and neck lymph node assessment: image quality and diagnostic impact compared with B-mode and Doppler ultrasonography. Ultrasound Med Biol 2016;42:387–98 doi:10.1016/j.ultrasmedbio.2015.10.019 pmid:26617244
    CrossRefPubMed
  21. 21.↵
    1. Rosenkrantz AB,
    2. Kim S,
    3. Lim RP, et al
    . Prostate cancer localization using multiparametric MR imaging: comparison of Prostate Imaging Reporting and Data System (PI-RADS) and Likert scales. Radiology 2013;269:482–92 doi:10.1148/radiol.13122233 pmid:23788719
    CrossRefPubMed
  22. 22.↵
    1. Migirov L,
    2. Greenberg G,
    3. Eyal A, et al
    . Imaging prior to endoscopic ear surgery: clinical note. Isr Med Assoc J 2014;16:191–93 pmid:24761713
    PubMed
  23. 23.↵
    1. Thiriat S,
    2. Riehm S,
    3. Kremer S, et al
    . Apparent diffusion coefficient values of middle ear cholesteatoma differ from abscess and cholesteatoma admixed infection. AJNR Am J Neuroradiol 2009;30:1123–26 doi:10.3174/ajnr.A1473 pmid:19246529
    Abstract/FREE Full Text
  24. 24.↵
    1. Dubrulle F,
    2. Souillard R,
    3. Chechin D, et al
    . Diffusion-weighted MR imaging sequence in the detection of postoperative recurrent cholesteatoma. Radiology 2006;238:604–10 doi:10.1148/radiol.2381041649 pmid:16304085
    CrossRefPubMed
  25. 25.↵
    1. Lichy MP,
    2. Wietek BM,
    3. Mugler JP, et al
    . Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences. Invest Radiol 2005;40:754–60 doi:10.1097/01.rli.0000185880.92346.9e pmid:16304477
    CrossRefPubMed
  26. 26.↵
    1. Casselman JW,
    2. Gieraerts K,
    3. Volders D, et al
    . Cone beam CT: non-dental applications. JBR-BTR 2013;96:333–53 pmid:24617175
    PubMed
  27. 27.↵
    1. Bernardeschi D,
    2. Lahlou G,
    3. De Seta D, et al
    . 3D endoscopic ear surgery: a clinical pilot study. Eur Arch Otorhinolaryngol 2018;275:379–84 doi:10.1007/s00405-017-4839-6 pmid:29209853
    CrossRefPubMed
  • Received February 27, 2019.
  • Accepted after revision June 17, 2019.
  • © 2019 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 40 (9)
American Journal of Neuroradiology
Vol. 40, Issue 9
1 Sep 2019
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Improved Assessment of Middle Ear Recurrent Cholesteatomas Using a Fusion of Conventional CT and Non-EPI-DWI MRI
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
F. Felici, U. Scemama, D. Bendahan, J.-P. Lavieille, G. Moulin, C. Chagnaud, M. Montava, A. Varoquaux
Improved Assessment of Middle Ear Recurrent Cholesteatomas Using a Fusion of Conventional CT and Non-EPI-DWI MRI
American Journal of Neuroradiology Sep 2019, 40 (9) 1546-1551; DOI: 10.3174/ajnr.A6141

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Improved Assessment of Middle Ear Recurrent Cholesteatomas Using a Fusion of Conventional CT and Non-EPI-DWI MRI
F. Felici, U. Scemama, D. Bendahan, J.-P. Lavieille, G. Moulin, C. Chagnaud, M. Montava, A. Varoquaux
American Journal of Neuroradiology Sep 2019, 40 (9) 1546-1551; DOI: 10.3174/ajnr.A6141
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Acknowledgments
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Diffusion Analysis of Intracranial Epidermoid, Head and Neck Epidermal Inclusion Cyst, and Temporal Bone Cholesteatoma
  • Fusion of middle ear optical coherence tomography and computed tomography in three ears
  • Comparison of the Utility of High-Resolution CT-DWI and T2WI-DWI Fusion Images for the Localization of Cholesteatoma
  • Crossref (4)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Combination of CT and MRT in the diagnostic of middle ear cholesteatoma. Fusion technology is precise localization tool
    S.Ya. Kosyakov, E.V. Pchelenok, E.A. Stepanova, O.Yu. Tarasova
    Vestnik otorinolaringologii 2021 86 5
  • Comparison of the Utility of High-Resolution CT-DWI and T2WI-DWI Fusion Images for the Localization of Cholesteatoma
    X. Fan, C. Ding, Z. Liu
    American Journal of Neuroradiology 2022 43 7
  • Diffusion Analysis of Intracranial Epidermoid, Head and Neck Epidermal Inclusion Cyst, and Temporal Bone Cholesteatoma
    Fabrício Guimarães Gonçalves, Amirreza Manteghinejad, Zekordavar Rimba, Dmitry Khrichenko, Angela N. Viaene, Arastoo Vossough
    American Journal of Neuroradiology 2024 45 11
  • Fusion of Middle Ear Optical Coherence Tomography and Computed Tomography
    Junzhe Wang, Floor Couvreur, Joshua D. Farrell, Reshma Ghedia, Nael Shoman, David P. Morris, Robert B. A. Adamson
    JAMA Otolaryngology–Head & Neck Surgery 2025 151 5

More in this TOC Section

  • Chondrosarcoma vs Synovial Chondromatosis: Imaging
  • WHO Classification Update: Nasal&Skull Base Tumors
  • Peritumoral Signal in Vestibular Schwannomas
Show more HEAD & NECK

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire