Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticlePatient Safety

Lens Exposure during Brain Scans Using Multidetector Row CT Scanners: Methods for Estimation of Lens Dose

S. Suzuki, S. Furui, T. Ishitake, T. Abe, H. Machida, R. Takei, K. Ibukuro, A. Watanabe, T. Kidouchi and Y. Nakano
American Journal of Neuroradiology May 2010, 31 (5) 822-826; DOI: https://doi.org/10.3174/ajnr.A1946
S. Suzuki
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Furui
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Ishitake
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Abe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Machida
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Takei
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K. Ibukuro
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Watanabe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Kidouchi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y. Nakano
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

References

  1. 1.↵
    1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP 1991;21:1–201
    FREE Full Text
  2. 2.↵
    1. Nakashima E,
    2. Neriishi K,
    3. Minamoto A
    . A reanalysis of atomic-bomb cataract data, 2000–2002: a threshold analysis. Health Phys 2006;90:154–60
    CrossRefPubMedWeb of Science
  3. 3.↵
    1. Neriishi K,
    2. Nakashima E,
    3. Minamoto A,
    4. et al
    . Postoperative cataract cases among atomic bomb survivors: radiation dose response and threshold. Radiat Res 2007;168:404–08
    CrossRefPubMedWeb of Science
  4. 4.↵
    1. Minamoto A,
    2. Taniguchi H,
    3. Yoshitani N,
    4. et al
    . Cataract in atomic bomb survivors. Int J Radiat Biol 2004;80:339–45
    CrossRefPubMedWeb of Science
  5. 5.↵
    1. Otake M,
    2. Neriishi K,
    3. Schull WJ
    . Cataract in atomic bomb survivors based on a threshold model and the occurrence of severe epilation. Radiat Res 1996;146:339–48
    CrossRefPubMedWeb of Science
  6. 6.↵
    1. Worgul BV,
    2. Kundiyev YI,
    3. Sergiyenko NM,
    4. et al
    . Cataracts among Chernobyl clean-up workers: implications regarding permissible eye exposures. Radiat Res 2007;167:233–43
    CrossRefPubMedWeb of Science
  7. 7.↵
    The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann ICRP 2007; 159– 171
  8. 8.↵
    1. Jones TR,
    2. Kaplan RT,
    3. Lane B,
    4. et al
    . Single- versus multi-detector row CT of the brain: quality assessment. Radiology 2001;219:750–55
    PubMed
  9. 9.↵
    1. Yeoman LJ,
    2. Howarth L,
    3. Britten A,
    4. et al
    . Gantry angulation in brain CT: dosage implications, effect on posterior fossa artifacts, and current international practice. Radiology 1992;184:113–16
    PubMed
  10. 10.↵
    1. Bauhs JA,
    2. Vrieze TJ,
    3. Primak AN,
    4. et al
    . CT dosimetry: comparison of measurement techniques and devices. Radiographics 2008;28:245–53
    CrossRefPubMedWeb of Science
  11. 11.↵
    1. Avilés Lucas P,
    2. Castellano IA,
    3. Dance DR,
    4. et al
    . Analysis of surface dose variation in CT procedures. Br J Radiol 2001;74:1128–36
    Abstract/FREE Full Text
  12. 12.↵
    1. Rafnsson V,
    2. Olafsdottir E,
    3. Hrafnkelsson J,
    4. et al
    . Cosmic radiation increases the risk of nuclear cataract in airline pilots: a population-based case-control study. Arch Ophthalmol 2005;123:1102–05
    CrossRefPubMedWeb of Science
  13. 13.↵
    1. Cucinotta FA,
    2. Manuel FK,
    3. Jones J,
    4. et al
    . Space radiation and cataracts in astronauts. Radiat Res 2001;156:460–66
    CrossRefPubMedWeb of Science
  14. 14.↵
    1. Wilde G,
    2. Sjöstrand J
    . A clinical study of radiation cataract formation in adult life following gamma irradiation of the lens in early childhood. J Ophthalmol 1997;81:261–66
  15. 15.↵
    1. Chen WL,
    2. Hwang JS,
    3. Hu TH,
    4. et al
    . Lenticular opacities in populations exposed to chronic low-dose-rate gamma radiation from radiocontaminated buildings in Taiwan. Radiat Res 2001;156:71–77
    CrossRefPubMedWeb of Science
  16. 16.↵
    1. Klein BE,
    2. Klein R,
    3. Linton KL,
    4. et al
    . Diagnostic x-ray exposure and lens opacities: the Beaver Dam Eye Study. Am J Public Health 1993;83:588–90
    CrossRefPubMedWeb of Science
  17. 17.↵
    1. Chodick G,
    2. Bekiroglu N,
    3. Hauptmann M,
    4. et al
    . Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists. Am J Epidemiol 2008;168:620–31
    Abstract/FREE Full Text
  18. 18.↵
    1. McNitt-Gray MF
    . AAPM/RSNA physics tutorial for residents: topics in CT—radiation dose in CT. Radiographics 2002;22:1541–53
    CrossRefPubMedWeb of Science
  19. 19.↵
    1. Smith A,
    2. Shah GA,
    3. Kron T
    . Variation of patient dose in head CT. Br J Radiol 1998;71:1296–301
    Abstract
  20. 20.↵
    Task Group on Control of Radiation Dose in Computed Tomography. Managing patient dose in computed tomography: a report of the International Commission on Radiological Protection. Ann ICRP 2000; 30: 7– 45
    PubMed
  21. 21.↵
    1. Lai KF,
    2. Cheung YK,
    3. Tan CB,
    4. et al
    . Lens exclusion in computed tomography scans of the brain: the local practice. J HK Coll Radiol 2001;4:181–84
  22. 22.↵
    1. Perisinakis K,
    2. Raissaki M,
    3. Theocharopoulos N,
    4. et al
    . Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head: a Monte Carlo study. Med Phys 2005;32:1024–30
    CrossRefPubMedWeb of Science
  23. 23.↵
    1. Hopper KD,
    2. Neuman JD,
    3. King SH,
    4. et al
    . Radioprotection to the eye during CT scanning. AJNR Am J Neuroradiol. 2001;22:1194–98
    Abstract/FREE Full Text
  24. 24.↵
    1. Demura S,
    2. Yamaji S,
    3. Nakada M,
    4. et al
    . Prediction equation for head volume of Japanese young adults. J Sports Sci 2005;23:541–48
    CrossRefPubMed
  25. 25.↵
    1. Shrimpton PC,
    2. Jones DG,
    3. Hillier MC,
    4. et al
    . Survey of CT practice in the UK. Part 2. Dosimetric aspects. In: National Radiological Protection Board, Report NRPB-R 249. London, UK: HMSO; 1991
  26. 26.↵
    1. Moss M,
    2. McLean D
    . Paediatric and adult computed tomography practice and patient dose in Australia. Australas Radiol 2006;50:33–40
    CrossRefPubMed
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 31 (5)
American Journal of Neuroradiology
Vol. 31, Issue 5
1 May 2010
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Lens Exposure during Brain Scans Using Multidetector Row CT Scanners: Methods for Estimation of Lens Dose
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S. Suzuki, S. Furui, T. Ishitake, T. Abe, H. Machida, R. Takei, K. Ibukuro, A. Watanabe, T. Kidouchi, Y. Nakano
Lens Exposure during Brain Scans Using Multidetector Row CT Scanners: Methods for Estimation of Lens Dose
American Journal of Neuroradiology May 2010, 31 (5) 822-826; DOI: 10.3174/ajnr.A1946

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Lens Exposure during Brain Scans Using Multidetector Row CT Scanners: Methods for Estimation of Lens Dose
S. Suzuki, S. Furui, T. Ishitake, T. Abe, H. Machida, R. Takei, K. Ibukuro, A. Watanabe, T. Kidouchi, Y. Nakano
American Journal of Neuroradiology May 2010, 31 (5) 822-826; DOI: 10.3174/ajnr.A1946
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref (28)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Imaging Evidence and Recommendations for Traumatic Brain Injury: Conventional Neuroimaging Techniques
    Max Wintermark, Pina C. Sanelli, Yoshimi Anzai, A. John Tsiouris, Christopher T. Whitlow, T. Jason Druzgal, Alisa D. Gean, Yvonne W. Lui, Alexander M. Norbash, Cyrus Raji, David W. Wright, Michael Zeineh
    Journal of the American College of Radiology 2015 12 2
  • Bismuth Shielding, Organ-based Tube Current Modulation, and Global Reduction of Tube Current for Dose Reduction to the Eye at Head CT
    Jia Wang, Xinhui Duan, Jodie A. Christner, Shuai Leng, Katharine L. Grant, Cynthia H. McCollough
    Radiology 2012 262 1
  • Ocular Anatomy and Cross-Sectional Imaging of the Eye
    Ajay Malhotra, Frank J. Minja, Alison Crum, Delilah Burrowes
    Seminars in Ultrasound, CT and MRI 2011 32 1
  • Lens Dose in Routine Head CT: Comparison of Different Optimization Methods With Anthropomorphic Phantoms
    Ulla Nikupaavo, Touko Kaasalainen, Vappu Reijonen, Sanna-Mari Ahonen, Mika Kortesniemi
    American Journal of Roentgenology 2015 204 1
  • Patient radiation biological risk in computed tomography angiography procedure
    M. Alkhorayef, E. Babikir, A. Alrushoud, H. Al-Mohammed, A. Sulieman
    Saudi Journal of Biological Sciences 2017 24 2
  • Radiation dose and risk to the lens of the eye during CT examinations of the brain
    Rebekah Poon, Mohamed K Badawy
    Journal of Medical Imaging and Radiation Oncology 2019 63 6
  • Estimation of radiation-induced cataract and cancer risks during routine CT head procedures
    M. Alkhorayef, A. Sulieman, B. Alonazi, M. Alnaaimi, M. Alduaij, D. Bradley
    Radiation Physics and Chemistry 2019 155
  • Cataract Formation and Low-Dose Radiation Exposure from Head Computed Tomography (CT) Scans in Ontario, Canada, 1994–2015
    Katherine Gaudreau, Christopher Thome, Bruce Weaver, Douglas R. Boreham
    Radiation Research 2020 193 4
  • Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings
    K Imai, M Ikeda, C Kawaura, T Aoyama, Y Enchi, M Yamauchi
    The British Journal of Radiology 2012 85 1017
  • Radioprotection of eye lens using protective material in neuro cone-beam computed tomography: Estimation of dose reduction rate and image quality
    Satoru Kawauchi, Koichi Chida, Takashi Moritake, Yusuke Hamada, Wataro Tsuruta
    Physica Medica 2021 82

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more PATIENT SAFETY

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire