Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • ASNR Foundation Special Collection
    • Most Impactful AJNR Articles
    • Photon-Counting CT
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR is seeking candidates for the AJNR Podcast Editor. Read the position description.

Research ArticlePEDIATRICS

Reduction of Oxygen-Induced CSF Hyperintensity on FLAIR MR Images in Sedated Children: Usefulness of Magnetization-Prepared FLAIR Imaging

H.-K. Jeong, S.W. Oh, J. Kim, S.-K. Lee and S.J. Ahn
American Journal of Neuroradiology August 2016, 37 (8) 1549-1555; DOI: https://doi.org/10.3174/ajnr.A4723
H.-K. Jeong
aFrom Philips Korea (H.-K.J.), Seoul, Republic of Korea
bKorea Basic Science Institute (H.-K.J.), Chungcheongbuk-do, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for H.-K. Jeong
S.W. Oh
cDepartment of Radiology (S.W.O), Soonchunhyang University Cheonan Hospital, Cheonan, Chungnam, Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.W. Oh
J. Kim
dDepartment of Radiology (J.K., S.-K.L., S.J.A.), Yonsei University College of Medicine, Seoul, Korea.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J. Kim
S.-K. Lee
dDepartment of Radiology (J.K., S.-K.L., S.J.A.), Yonsei University College of Medicine, Seoul, Korea.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.-K. Lee
S.J. Ahn
dDepartment of Radiology (J.K., S.-K.L., S.J.A.), Yonsei University College of Medicine, Seoul, Korea.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.J. Ahn
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Oxygen-induced CSF hyperintensity on FLAIR MR imaging is often observed in sedated children. This phenomenon can mimic leptomeningeal pathology and lead to a misdiagnosis. The purpose of this study was to investigate whether magnetization-prepared FLAIR MR imaging can reduce oxygen-induced CSF hyperintensity and improve image quality compared with conventional (non-magnetization-prepared) FLAIR MR imaging.

MATERIALS AND METHODS: Bloch simulation for magnetization-prepared and non-magnetization-prepared FLAIR sequences was performed for tissue contrast. We retrospectively reviewed 85 children with epilepsy who underwent MR imaging under general anesthesia with supplemental oxygen (41 with non-magnetization-prepared FLAIR and 44 with magnetization-prepared FLAIR). CSF hyperintensity was scored from 0 to 3 points according to the degree of CSF signal intensity and was compared between the 2 sequences. The contrast-to-noise ratios among GM, WM, and CSF were evaluated to assess general image quality from both sequences. To assess the diagnostic accuracy for hemorrhage, we reviewed an additional 25 patients with hemorrhage.

RESULTS: Bloch simulation demonstrated that CSF hyperintensity can be reduced on magnetization-prepared FLAIR compared with non-magnetization-prepared FLAIR. CSF hyperintensity scores were significantly lower in magnetization-prepared FLAIR than in non-magnetization-prepared FLAIR (P < .01). The contrast-to-noise ratios for GM-WM, GM-CSF, and WM-CSF were significantly higher in magnetization-prepared FLAIR than in non-magnetization-prepared FLAIR (P < .05). Hemorrhage was clearly demarcated from CSF hyperintensity in the magnetization-prepared group (100%, 12/12) and non-magnetization-prepared group (38%, 5/13).

CONCLUSIONS: Magnetization-prepared 3D-FLAIR MR imaging can significantly reduce oxygen-induced CSF artifacts and increase the tissue contrast-to-noise ratio beyond the levels achieved with conventional non-magnetization-prepared 3D-FLAIR MR imaging.

ABBREVIATIONS:

MP
magnetization-prepared
oxy-CSF
oxygenated CSF

MR imaging is the diagnostic tool of choice in pediatric neurologic diseases because it has no ionizing radiation and is noninvasive. However, sedation is unavoidable if suitable MR images are sought because pediatric patients usually do not cooperate during long-duration scans.

CSF hyperintensity on FLAIR MR images is frequently encountered in sedated children.1⇓⇓⇓–5 These artifacts cause a diagnostic dilemma because they can mimic hemorrhage, infection, and leptomeningeal seeding metastasis, which are all known to generate hyperintense CSF signals on FLAIR MR images.6⇓⇓–9 Initially, CSF hyperintensity was attributed to anesthetic-induced T1-shortening, protein redistribution due to changes in the intravascular membrane permeability, hyperdynamic CSF pulsation due to altered vascular tone, and supplemental oxygen during anesthesia.2⇓–4,10 However, several studies have revealed that the most plausible cause of hyperintense CSF artifacts in FLAIR imaging is the administration of supplemental oxygen during anesthesia.1,2,4,5,10

Oxygen is a weak paramagnetic substance, which has 2 unpaired electrons that can cause a moderate increase in the T1 relaxation rate.11,12 Studies have shown that the diffusional transfer of oxygen from blood to CSF and a consequent FLAIR MR signal increase depend on the inhaled oxygen concentration1,2,4,13 and oxygen delivery methods.3,10

3D-FLAIR imaging is based on the 3D TSE imaging technique that modulates a refocusing flip angle at the TSE echo-train to maintain relatively steady signal levels during a long train of echo signals, which can provide improved image sharpness, helpful in detecting small structures. Consequently, the relaxation-induced image blurring, partial volume effect, and specific absorption rate can be reduced allowing high-resolution 3D data acquisition at isotropic voxels during clinically feasible scan durations.14 3D-FLAIR also provides increased SNR and reduces CSF pulsation artifacts compared with 2D FLAIR.5,15⇓⇓–18 In magnetization-prepared (MP) 3D-FLAIR imaging, a dedicated magnetization preparation is implemented before typical inversion recovery, followed by TSE imaging, which is known to reduce unwanted T1-weighting and image TR.19,20 Therefore, the purpose of this study was to compare magnetization-prepared 3D-FLAIR imaging with conventional (non-MP) 3D-FLAIR imaging in terms of the ability to reduce oxygen-induced CSF hyperintensity and improve image quality in sedated pediatric patients.

Materials and Methods

Study Population

We retrospectively screened consecutive children with epilepsy who were referred to our pediatric neurology outpatient clinic from June 2014 to June 2015. This retrospective study was approved by the institutional review board of Severance hospital. We included patients who underwent MR imaging by using a routine seizure protocol in the hospital and excluded patients with a history of brain operations due to the possibility of metal artifacts. We identified 85 pediatric patients (51 boys and 34 girls; age range, 0–12 years; mean age, 6 years). Detailed demographic characteristics and MR imaging findings are described in Table 1.

View this table:
  • View inline
  • View popup
Table 1:

Demographic characteristics and MRI findings

To assess the diagnostic accuracy for hemorrhage, we additionally included in the study 25 patients (17 boys and 8 girls; age range, 0–10 years; mean age, 5 years) who underwent neurosurgery due to epilepsy in our hospital from June 2014 to June 2015. These patients underwent immediate postoperative brain CT and MR imaging sequentially within 3 days after the operation. Hemorrhage was detected on their brain CTs. Patients were excluded if hemorrhage was not detected on the brain CT scan. In most cases, the preoperative MR imaging findings were normal (11/25, 44%); however, cortical malformation (9/25, 36%), ischemia (3/25, 12%), tumor (6/25, 24%), and hippocampal sclerosis (1/25, 4%) were also observed. The most frequent type of operation performed was callosotomy (13/25, 52%), followed by lesionectomy (6/25, 24%), lobectomy (4/25, 16%), and hemispherectomy (2/25, 8%).

MR Imaging

All pediatric patients were examined with 1 of 2 3T MR imaging scanners (Achieva; Philips Medical System, Best, the Netherlands). One MR imaging scanner was operated with the conventional (non-MP) 3D-FLAIR imaging protocol, and the other MR imaging scanner was operated with the MP 3D-FLAIR imaging protocol due to the difference in the MR imaging scanner software versions. Patients were randomly assigned to 1 of the 2 MR imaging scanners according to a patient schedule and the availability of the scanners. The scan parameters for FLAIR imaging were optimal for suppression of CSF signals and are used for nonsedated adult patients in our institution. Detailed imaging and sequence timing parameters are shown in Table 2.

View this table:
  • View inline
  • View popup
Table 2:

Imaging and sequence timing parameters for non-MP and MP 3D-FLAIR

In our pediatric neurology clinic, general anesthesia was recommended to achieve a suitable diagnostic quality in the acquired MR images. Parent consent was obtained by the anesthesiologist before each procedure. Anesthesia was induced at an infusion rate of 125–250 μg of propofol per kilogram of body weight per minute, and all patients breathed spontaneously with supplemental 70%–80% oxygen via a nasal cannula during anesthesia.

Simulation

The magnetization behavior was simulated by using Bloch equations for the current MR imaging sequence and parameters as shown in Fig 1 and Table 2, respectively. The magnetization preparation used in 3D-FLAIR included nonselective radiofrequency pulses that consisted of a 90° block pulse for excitation, followed by 4 hyperbolic secant adiabatic refocusing pulses and a −90° flip-up pulse (FU). This was followed by inversion recovery, fat-saturation, and TSE readout with a variable refocusing flip angle scheme available in the scanner.19 The longitudinal magnetization after magnetization preparation and inversion recovery before TSE readout can be represented as follows: Embedded Image where M0 is the equilibrium magnetization, Mz is the longitudinal magnetization, and τ1, τ2, τ3, and τ4 are the sequence timing parameters, as shown in Fig 1 and Table 2. The superscript “minus sign” represents the time before radiofrequency irradiation. When τ3 is negligible, Equation 1 can be reduced to Embedded Image and Equation 2 becomes Mz.19,20 When magnetization preparation is not used, longitudinal magnetization can be represented as follows: Embedded Image and Equation 3 becomes Mz for inversion recovery.13,19 The evolution of magnetization with and without magnetization preparation was simulated to determine T1-weighting and signal contrast among brain tissues. In the simulation, the imaging and sequence timing parameters used are shown in Table 2, and the tissue relaxation parameters are demonstrated in Table 3.13,21⇓⇓–24 Because there was no significant difference in the T2 relaxation constant between CSF and oxygenated CSF (oxy-CSF),10,13 the T2 relaxation constant for oxy-CSF was assumed to be equal to that of the CSF. The simulation was performed with effective TE, where the T2 contrast in the pure T2-weighting sequence was equivalent to the T2 contrast in a sequence with a long refocusing train of radiofrequency with a variable flip angle.19,25

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Pulse sequence diagram for MP 3D-FLAIR imaging. Magnetization preparation is implemented during τ2 with radiofrequency pulses for 90° excitation (EX), followed by T2-preparation and −90° flip-up (FU). FLAIR inversion recovery is achieved during τ1 with radiofrequency pulses for inversion (INV), followed by spectral fat saturation (FS) and TSE readout with 90° excitation (EX), followed by a train of refocusing pulses during τ5. τ3 and τ4 are the times for gradient spoiling and to the end of the current TR period, respectively. Black shaded trapezoids represent spoiling gradients to eliminate transverse magnetization.

View this table:
  • View inline
  • View popup
Table 3:

Tissue relaxation parameters

Image Analysis

Two experienced neuroradiologists (S.J.A. with 4 years of experience in neuroimaging and J.K. with 10 years of experience in neuroimaging) were blinded to the patient information and imaging sequences. In the first session, the investigators independently evaluated CSF hyperintensity on non-MP 3D-FLAIR and MP 3D-FLAIR images, modifying a previous method.5 Imaging data were randomly assigned to each reader. CSF hyperintensity artifacts were scored from 0 to 3 according to the degree of the CSF signal intensity: 0, no visual CSF signal; 1, homogeneous diffuse minimal CSF signal; 2, CSF signal similar to that of the pons; 3, CSF signal higher than that of the pons (On-line Fig). The premedullary, prepontine, suprasellar, basal, ambient, quadrigeminal cistern, and sulci regions of the cerebral convex were evaluated. The averaged values of CSF hyperintensity from each neuroradiologist were used for further analysis.

To assess tissue contrast on 2 sequences, a third neuroradiologist (S.W.O. with 2 years of experience in neuroimaging) independently drew 4 circular ROIs (area = 10 mm2) in the caudate nucleus of the right basal ganglia and averaged the values representing GM. He was blinded to the patient information and sequences. Averaged values for the ROIs from the right frontal subcortical WM and adjacent lateral ventricle at the same plane represent WM and CSF, respectively. To ensure identical placement of the ROIs on both sequences, he carefully positioned the ROIs by hand in the same region of both images. Contrast-to-noise ratios were calculated among the GM, WM, and CSF. A contrast-to-noise ratio was defined on the basis of the signal intensity (SI) and SD in the ROI as follows: Embedded Image where the subscripts i and j for SI and SD represent tissue types, such as GM, WM, or CSF.

Three weeks later, in the second session, the first 2 radiologists assessed whether the intracranial hemorrhage that occurred after neurosurgery could be clearly demarcated from CSF hyperintensity in the second study population. The decision for discrepant cases was established by consensus between the 2 neurologists. The flow chart for image analysis is summarized in Fig 2.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

Flow chart for image analysis. CNR indicates contrast-to-noise ratio.

Statistical Analysis

CSF hyperintensity artifact scores for the premedullary, prepontine, suprasellar, basal, ambient, quadrigeminal cistern, and sulci regions of the cerebral convex were compared between non-MP 3D-FLAIR and MP 3D-FLAIR images by using the Student t test. Interobserver agreement for CSF hyperintensity was analyzed by using κ statistics. The contrast-to-noise ratios (GM/WM, GM/CSF, and WM/CSF) were compared between the 2 FLAIR MR imaging sequences. Statistical analyses were performed by using commercial software (MedCalc for Windows, Version 10.1.2.0; MedCalc Software, Mariakerke, Belgium). A P value < .05 was statistically significant.

Results

Figure 3 shows the simulation results for the evolution of steady-state magnetization for the non-MP and MP sequences by using imaging and sequence timing parameters and tissue relaxation constants. Magnetization preparation (τ2) induced lower T1-weighting than the non-MP sequences. Finally, oxygen-induced CSF hyperintensities were markedly reduced, and the contrast between GM and WM was enhanced at the TE on MP FLAIR images compared with non-MP FLAIR images (see magnified view in Fig 3).

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

Simulation results for the evolution of steady-state magnetization for each type of tissue (WM, GM, CSF, and oxy-CSF) are presented for non-MP (A) and MP (B) FLAIR sequences. Imaging and sequence timing parameters (Table 2) and tissue relaxation constants (Table 3) were used in simulation. Sequence timing parameters (τ1 ∼ τ5) are presented along with the time axis at each figure. An inset within each figure presents a magnified segment of the evolution of magnetization around the TE (dotted black vertical line). A.U. indicates arbitrary unit.

CSF hyperintensity artifact scores for the premedullary, prepontine, suprasellar, basal, ambient, quadrigeminal cistern, and sulci regions of the cerebral convex were significantly lower in MP 3D-FLAIR than in non-MP 3D-FLAIR (Fig 4 and Table 4). The interobserver agreement between the 2 readers was excellent for CSF hyperintensity artifact scores (κ > 0.85).

Fig 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 4.

The non-MP 3D-FLAIR sequences of a 3-year-old boy with epilepsy (upper row). CSF hyperintensity artifact scores totaled 17 (premedullary cistern, 2; prepontine cistern, 2; suprasellar cistern, 3; basal cistern, 3; ambient cistern, 3; quadrigeminal cistern, 3; sulci of cerebral convex, 1). MP 3D-FLAIR sequences of a 4-year-old boy with epilepsy (lower row). CSF hyperintensity artifact scores totaled 4 (premedullary cistern, 0; prepontine cistern, 0; suprasellar cistern, 1; basal cistern, 1; ambient cistern, 1; quadrigeminal cistern, 1; sulci of the cerebral convex, 0).

View this table:
  • View inline
  • View popup
Table 4:

Hyperintense CSF artifact scores and CNR between GM and WM

The contrast-to-noise ratio values for GM-WM, GM-CSF, and WM-CSF were significantly higher on MP 3D-FLAIR than on non-MP 3D-FLAIR (Table 4).

Hemorrhage was clearly demarcated from CSF hyperintensity in all 12 patients who underwent the MP sequence but in only 5 of 13 patients (38%) who underwent the non-MP sequence (Fig 5). There were no instances of discrepancy between the investigators.

Fig 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 5.

The subdural hemorrhage (solid arrow) is suspected in the non-MP 3D-FLAIR (upper row) of a 5-year-old girl after a callosotomy, which is also observed in the immediate postoperative CT scan. However, it is not clearly demarcated from CSF hyperintensity artifacts (dotted arrow). Hemorrhage (solid arrow) is clearly demarcated in the MP 3D-FLAIR (lower row) of an 8-month-old boy after lesionectomy, which is also observed in the immediate postoperative CT scan because CSF hyperintensity artifacts are suppressed.

Discussion

In this study, we found that oxygen-induced CSF hyperintensity was significantly reduced in MP 3D-FLAIR compared with non-MP 3D-FLAIR. Moreover, MP 3D-FLAIR provided higher contrast-to-noise ratios among GM, WM, and CSF than non-MP 3D-FLAIR. The clinical implications of this observation are important because supplemental oxygen-induced hyperintense CSF artifacts can reduce the diagnostic accuracy of CSF pathology in sedated pediatric patients.1,10 Therefore, MP 3D-FLAIR can improve the diagnosis rate of CSF abnormalities and provide enhanced contrast among GM, WM, and CSF.

Previous studies hypothesized that CSF hyperintensity is associated with anesthetic-induced T1 shortening or redistribution of proteins due to changes in intravascular membrane permeability. However, subsequent studies have revealed that this hypothesis might not be valid. For example, Deliganis et al2 investigated the impact of the T1 relaxation constant on different anesthetic solutions with varying anesthetic concentrations that ranged from low-to-high clinical dose levels. They found no major differences in T1 over diverse anesthetic concentrations. Anzai et al10 showed, in a phantom study, that no noticeable FLAIR signal changes were observed over various albumin concentrations, except at a very high concentration (>1250 mg/dL). The normal CSF protein content is 22–52 mg/dL26: 15–45 mg/dL in adults and 20–120 mg/dL in children.3 Vascular pulsation might partially explain CSF hyperintensity, but these effects can be reduced further by using 3D-FLAIR imaging in place of 2D FLAIR imaging.15⇓⇓–18 Additionally, pulsation artifacts can be easily distinguished by analyzing the signal-intensity pattern distributions throughout the brain.2

Studies claim that the most reliable explanation for CSF hyperintensity in sedated pediatric patients is attributable to the T1-shortening effect caused by the high concentration of paramagnetic supplemental oxygen administered during anesthesia. Moreover, various experimental factors (eg, inhaled oxygen concentrations and oxygen delivery methods) during supplemental oxygen administration are known to influence CSF hyperintensity. Deliganis et al2 found that a patient who received 50% supplemental oxygen did not demonstrate any CSF hyperintensity, whereas patients with 100% supplemental oxygen showed noticeable signal increases in FLAIR images. This finding was confirmed in the study by Frigon et al,4 in which CSF hyperintensity was observed in patients with 100% supplemental oxygen but only partial or no CSF hyperintensity was observed in patients with 30% oxygen inhalation. In a study with healthy volunteers, Anzai et al10 observed CSF hyperintensity with 100% supplemental oxygen but no visible CSF hyperintensity in room air conditions (21% oxygen inhalation). The oxygen delivery method affects the efficiency of oxygen transport from the blood to the CSF. Oxygen delivery methods (eg, loose oxygen mask, nonrebreathing oxygen mask, or nasal cannula) were also reported to be important factors that influence CSF hyperintensity.3,10

Oxygen distribution within the CSF is facilitated by diffusion of dissolved free oxygen from the blood into the CSF because there are no oxygen-carrying molecules such as hemoglobin or myoglobin in the CSF. Although dissolved free oxygen occupies only a small fraction of blood (<0.3%), a relatively large amount of inhaled oxygen can increase the concentration and facilitate oxygen transport into the CSF.2,10 The primary locations of oxygen entry into the CSF have been reported to be regions where large arterial vessels are lined with abundant pia-arachnoid surface areas.2,10 According to our results, CSF hyperintensity was more prominent in the suprasellar, basal, ambient, and quadrigeminal cistern than in the premedullary, prepontine cistern, and sulci regions of the cerebral convex on both MP and non-MP FLAIR sequences. These regional differences in the appearance of CSF hyperintensity can be explained by the following factors: First, the amount of CSF that surrounds the suprasellar, basal, ambient, and quadrigeminal cisterns is relatively small; therefore, there would be relatively less dilution of dissolved oxygen than in the premedullary and prepontine cisterns, which contain larger CSF pools.10 Second, the pituitary and pineal glands are circumventricular organs that have leaky blood-brain barriers, and they might facilitate the transport of dissolved oxygen into the CSF in the basal, suprasellar, ambient, and quadrigeminal cisterns.27 However, this regional differential appearance of CSF hyperintensity requires further investigation.

In this study, Bloch simulations were used to compare MP and non-MP FLAIR sequences with previously reported tissue relaxation properties and sequence timing parameters. The behavior of the simulated FLAIR signals was compatible with that in our in vivo observations, in which the magnitude of MR signals was oxy-CSF > GM > WM in non-MP FLAIR and GM > WM > oxy-CSF in MP FLAIR. The tissue magnetizations experienced inversion recovery in non-MP FLAIR, while they behaved more like saturation recovery in MP FLAIR,19 providing an oxy-CSF MP FLAIR longitudinal magnetization of only 67% to the non-MP FLAIR longitudinal magnetization before excitation (τ1). Therefore, superior suppression of CSF hyperintensity might be achieved in MP FLAIR compared with non-MP FLAIR. Because magnetization preparation reduces T1 shortening, it is possible that the sensitivity of the detection of leptomeningeal pathology also decreases. However, according to our results, hemorrhage was clearly demarcated from CSF hyperintensity on MP FLAIR, whereas it was difficult to differentiate hemorrhage from CSF hyperintensity on non-MP FLAIR. Reducing T1 shortening might not be enough to suppress the signal intensity of hemorrhage. In addition, suppression of CSF artifacts makes it easier to assess the extent of hemorrhage on MP 3D-FLAIR compared with non-MP FLAIR.

The magnetization preparation provided additional benefits other than reducing CSF hyperintensity. The desired T2 contrast can be compromised because of reducing unwanted T1-weighting. MP 3D-FLAIR imaging provided better T2-weighted contrast among GM, WM, and CSF than non-MP 3D-FLAIR imaging. The improved contrast between GM and WM is crucial for identifying and characterizing epileptogenic lesions.28 Therefore, MP 3D-FLAIR might also be helpful for detecting epileptic foci, which can be verified in a future study.

There were some limitations in this study. First, on FLAIR images, WM progressed from hyperintense to hypointense relative to adjacent GM during the first 2 years of life, which is slightly delayed compared with the observations on T2-weighted images.29,30 Therefore, young children with incomplete myelination may have different GM-MW contrast enhancements from those in older children. Our cohort was heterogeneous, ranging in age from 0 to 12 years, which might have affected the contrast-to-noise ratios. However, our Bloch simulation also supports our GM-WM contrast findings. Therefore, our results might be applicable to patients with complete myelination. Future studies with larger and more homogeneous populations are necessary to validate and extend these results. Second, in the simulation, we used an oxy-CSF T1 constant of 3510 ms on the basis of a study that used 1.5T MR imaging13 because the oxy-CSF T1 constant at 3T MR imaging was not available. However, the simulated FLAIR signal was comparable with that our in vivo observations. Accurate measurement of the oxy-CSF T1 constant at 3T MR imaging is required for more effective sequence design and in vivo application.

Conclusions

MP 3D-FLAIR imaging yields fewer CSF hyperintensity artifacts and provides superior contrast between GM and WM compared with non-MP 3D-FLAIR imaging. Therefore, we propose that MP 3D-FLAIR imaging provides better diagnostic accuracy in CSF pathologies and epileptogenic lesions in sedated pediatric patients who receive supplemental oxygen.

Footnotes

  • Disclosures: Ha-Kyu Jeong—RELATED: Employment: Philips Korea (regular salary).

  • This study was supported by the Dongkook Pharmaceutical Co, Ltd, Korea. The authors have no conflicts of interest that are directly relevant to the contents of this study.

References

  1. 1.↵
    1. Braga FT,
    2. da Rocha AJ,
    3. Hernandez Filho G, et al
    . Relationship between the concentration of supplemental oxygen and signal intensity of CSF depicted by fluid-attenuated inversion recovery imaging. AJNR Am J Neuroradiol 2003;24:1863–68 pmid:14561617
    Abstract/FREE Full Text
  2. 2.↵
    1. Deliganis AV,
    2. Fisher DJ,
    3. Lam AM, et al
    . Cerebrospinal fluid signal intensity increase on FLAIR MR images in patients under general anesthesia: the role of supplemental O2. Radiology 2001;218:152–56 doi:10.1148/radiology.218.1.r01ja43152 pmid:11152794
    CrossRefPubMed
  3. 3.↵
    1. Filippi CG,
    2. Ulug AM,
    3. Lin D, et al
    . Hyperintense signal abnormality in subarachnoid spaces and basal cisterns on MR images of children anesthetized with propofol: new fluid-attenuated inversion recovery finding. AJNR Am J Neuroradiol 2001;22:394–99 pmid:11156789
    Abstract/FREE Full Text
  4. 4.↵
    1. Frigon C,
    2. Shaw DW,
    3. Heckbert SR, et al
    . Supplemental oxygen causes increased signal intensity in subarachnoid cerebrospinal fluid on brain FLAIR MR images obtained in children during general anesthesia. Radiology 2004;233:51–55 doi:10.1148/radiol.2331031375 pmid:15454616
    CrossRefPubMed
  5. 5.↵
    1. Ozcan UA,
    2. Isik U,
    3. Ozpinar A, et al
    . Assessment of sedated pediatric brain with 3D-FLAIR sequence at 3T MRI. Brain Dev 2015;37:495–500 doi:10.1016/j.braindev.2014.08.008 pmid:25282484
    CrossRefPubMed
  6. 6.↵
    1. Mohamed M,
    2. Heasly DC,
    3. Yagmurlu B, et al
    . Fluid-attenuated inversion recovery MR imaging and subarachnoid hemorrhage: not a panacea. AJNR Am J Neuroradiol 2004;25:545–50 pmid:15090339
    Abstract/FREE Full Text
  7. 7.↵
    1. Noguchi K,
    2. Ogawa T,
    3. Seto H, et al
    . Subacute and chronic subarachnoid hemorrhage: diagnosis with fluid-attenuated inversion-recovery MR imaging. Radiology 1997;203:257–62 doi:10.1148/radiology.203.1.9122404 pmid:9122404
    CrossRefPubMed
  8. 8.↵
    1. Bozzao A,
    2. Bastianello S,
    3. Bozzao L
    . Superior sagittal sinus thrombosis with high-signal-intensity CSF mimicking subarachnoid hemorrhage on MR FLAIR images. AJR Am J Roentgenol 1997;169:1183–84 doi:10.2214/ajr.169.4.9308487 pmid:9308487
    CrossRefPubMed
  9. 9.↵
    1. Dechambre SD,
    2. Duprez T,
    3. Grandin CB, et al
    . High signal in cerebrospinal fluid mimicking subarachnoid haemorrhage on FLAIR following acute stroke and intravenous contrast medium. Neuroradiology 2000;42:608–11 doi:10.1007/s002340000347 pmid:10997567
    CrossRefPubMed
  10. 10.↵
    1. Anzai Y,
    2. Ishikawa M,
    3. Shaw DW, et al
    . Paramagnetic effect of supplemental oxygen on CSF hyperintensity on fluid-attenuated inversion recovery MR images. AJNR Am J Neuroradiol 2004;25:274–79 pmid:14970030
    Abstract/FREE Full Text
  11. 11.↵
    1. Berthezene Y,
    2. Tournut P,
    3. Turjman F, et al
    . Inhaled oxygen: a brain MR contrast agent? AJNR Am J Neuroradiol 1995;16:2010–12 pmid:8585488
    Abstract
  12. 12.↵
    1. Runge VM,
    2. Stewart RG,
    3. Clanton JA, et al
    . Work in progress: potential oral and intravenous paramagnetic NMR contrast agents. Radiology 1983;147:789–91 doi:10.1148/radiology.147.3.6844614 pmid:6844614
    CrossRefPubMed
  13. 13.↵
    1. Zaharchuk G,
    2. Martin AJ,
    3. Rosenthal G, et al
    . Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI. Magn Reson Med 2005;54:113–21 doi:10.1002/mrm.20546 pmid:15968660
    CrossRefPubMed
  14. 14.↵
    1. Busse RF,
    2. Hariharan H,
    3. Vu A, et al
    . Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Magn Reson Med 2006;55:1030–37 doi:10.1002/mrm.20863 pmid:16598719
    CrossRefPubMed
  15. 15.↵
    1. Kallmes DF,
    2. Hui FK,
    3. Mugler JP 3rd.
    . Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience. Radiology 2001;221:251–55 doi:10.1148/radiol.2211001712 pmid:11568348
    CrossRefPubMed
  16. 16.↵
    1. Kitajima M,
    2. Hirai T,
    3. Shigematsu Y, et al
    . Comparison of 3D FLAIR, 2D FLAIR, and 2D T2-weighted MR imaging of brain stem anatomy. AJNR Am J Neuroradiol 2012;33:922–27 doi:10.3174/ajnr.A2874 pmid:22268088
    Abstract/FREE Full Text
  17. 17.↵
    1. Naganawa S,
    2. Koshikawa T,
    3. Nakamura T, et al
    . Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T. Eur Radiol 2004;14:1901–08 pmid:15221269
    PubMed
  18. 18.↵
    1. Wu HM,
    2. Yousem DM,
    3. Chung HW, et al
    . Influence of imaging parameters on high-intensity cerebrospinal fluid artifacts in fast-FLAIR MR imaging. AJNR Am J Neuroradiol 2002;23:393–99 pmid:11901006
    Abstract/FREE Full Text
  19. 19.↵
    1. Visser F,
    2. Zwanenburg JJ,
    3. Hoogduin JM, et al
    . High-resolution magnetization-prepared 3D-FLAIR imaging at 7.0 Tesla. Magn Reson Med 2010;64:194–202 doi:10.1002/mrm.22397 pmid:20572143
    CrossRefPubMed
  20. 20.↵
    1. Wong EC,
    2. Liu TT,
    3. Luh WM, et al
    . T(1) and T(2) selective method for improved SNR in CSF-attenuated imaging: T(2)-FLAIR. Magn Reson Med 2001;45:529–32 pmid:11241715
    CrossRefPubMed
  21. 21.↵
    1. Lu H,
    2. Nagae-Poetscher LM,
    3. Golay X, et al
    . Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging 2005;22:13–22 doi:10.1002/jmri.20356 pmid:15971174
    CrossRefPubMed
  22. 22.↵
    1. Neeb H,
    2. Zilles K,
    3. Shah NJ
    . A new method for fast quantitative mapping of absolute water content in vivo. Neuroimage 2006;31:1156–68 doi:10.1016/j.neuroimage.2005.12.063 pmid:16650780
    CrossRefPubMed
  23. 23.↵
    1. Smith SA,
    2. Edden RA,
    3. Farrell JA, et al
    . Measurement of T1 and T2 in the cervical spinal cord at 3 Tesla. Magn Reson Med 2008;60:213–19 doi:10.1002/mrm.21596 pmid:18581383
    CrossRefPubMed
  24. 24.↵
    1. Stanisz GJ,
    2. Odrobina EE,
    3. Pun J, et al
    . T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005;54:507–12 doi:10.1002/mrm.20605 pmid:16086319
    CrossRefPubMed
  25. 25.↵
    1. Hennig J,
    2. Weigel M,
    3. Scheffler K
    . Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS). Magn Reson Med 2003;49:527–35 doi:10.1002/mrm.10391 pmid:12594756
    CrossRefPubMed
  26. 26.↵
    1. Melhem ER,
    2. Jara H,
    3. Eustace S
    . Fluid-attenuated inversion recovery MR imaging: identification of protein concentration thresholds for CSF hyperintensity. AJR Am J Roentgenol 1997;169:859–62 doi:10.2214/ajr.169.3.9275912 pmid:9275912
    CrossRefPubMed
  27. 27.↵
    1. Cottrell GT,
    2. Ferguson AV
    . Sensory circumventricular organs: central roles in integrated autonomic regulation. Regul Pept 2004;117:11–23 doi:10.1016/j.regpep.2003.09.004 pmid:14687696
    CrossRefPubMed
  28. 28.↵
    1. Vattipally VR,
    2. Bronen RA
    . MR imaging of epilepsy: strategies for successful interpretation. Neuroimaging Clin N Am 2004;14:349–72 doi:10.1016/j.nic.2004.04.002 pmid:15324853
    CrossRefPubMed
  29. 29.↵
    1. Murakami JW,
    2. Weinberger E,
    3. Shaw DW
    . Normal myelination of the pediatric brain imaged with fluid-attenuated inversion-recovery (FLAIR) MR imaging. AJNR Am J Neuroradiol 1999;20:1406–11 pmid:10512220
    Abstract/FREE Full Text
  30. 30.↵
    1. Welker KM,
    2. Patton A
    . Assessment of normal myelination with magnetic resonance imaging. Semin Neurol 2012;32:15–28 doi:10.1055/s-0032-1306382 pmid:22422203
    CrossRefPubMed
  • Received December 16, 2015.
  • Accepted after revision January 5, 2016.
  • © 2016 by American Journal of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 37 (8)
American Journal of Neuroradiology
Vol. 37, Issue 8
1 Aug 2016
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reduction of Oxygen-Induced CSF Hyperintensity on FLAIR MR Images in Sedated Children: Usefulness of Magnetization-Prepared FLAIR Imaging
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
H.-K. Jeong, S.W. Oh, J. Kim, S.-K. Lee, S.J. Ahn
Reduction of Oxygen-Induced CSF Hyperintensity on FLAIR MR Images in Sedated Children: Usefulness of Magnetization-Prepared FLAIR Imaging
American Journal of Neuroradiology Aug 2016, 37 (8) 1549-1555; DOI: 10.3174/ajnr.A4723

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Reduction of Oxygen-Induced CSF Hyperintensity on FLAIR MR Images in Sedated Children: Usefulness of Magnetization-Prepared FLAIR Imaging
H.-K. Jeong, S.W. Oh, J. Kim, S.-K. Lee, S.J. Ahn
American Journal of Neuroradiology Aug 2016, 37 (8) 1549-1555; DOI: 10.3174/ajnr.A4723
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref (6)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • More on Neurologic Features in Severe SARS-CoV-2 Infection
    New England Journal of Medicine 2020 382 26
  • Comparison of Contrast-Enhanced T2 FLAIR and 3D T1 Black-Blood Fast Spin-Echo for Detection of Leptomeningeal Metastases
    Yae Won Park, Sung Jun Ahn
    Investigative Magnetic Resonance Imaging 2018 22 2
  • Contrast‐Enhanced Fluid‐Attenuated Inversion Recovery in Neuroimaging: A Narrative Review on Clinical Applications and Technical Advances
    Sung Jun Ahn, Toshiaki Taoka, Won‐Jin Moon, Shinji Naganawa
    Journal of Magnetic Resonance Imaging 2022 56 2
  • Interpretation of fluid-attenuated inversion recovery vascular hyperintensity in stroke
    Kyung-Yul Lee, Jin Woo Kim, Mina Park, Sang Hyun Suh, Sung Jun Ahn
    Journal of Neuroradiology 2022 49 3
  • Prominent cerebral veins on susceptibility‐weighted angiography in acute meningoencephalitis
    Yo Han Jung, Mina Park, Bio Joo, Sang Hyun Suh, Kyung‐Yul Lee, Sung Jun Ahn
    Brain and Behavior 2023 13 11
  • Proper fraction of inspired oxygen for reduction of oxygen-induced canine cerebrospinal fluid hyperintensity on fluid attenuation inversion recovery sequence using low-field magnetic resonance imaging
    Moonjung JANG, Jaewoo HWANG, Jihye NAM, Dalhae KIM, Wongyun SON, Inhyung LEE, Mincheol CHOI, Junghee YOON
    Journal of Veterinary Medical Science 2020 82 9

More in this TOC Section

  • SyMRI & MR Fingerprinting in Brainstem Myelination
  • Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
  • Venous Sinus Stenosis in Mucopolysaccharidosis I
Show more Pediatrics

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • AJNR Awards
  • ASNR Foundation Special Collection
  • Most Impactful AJNR Articles
  • Photon-Counting CT
  • Spinal CSF Leak Articles (Jan 2020-June 2024)

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire